FOTILE SD2F-P3, SD2F-P3L In Sink Dishwasher Installation Guide

June 3, 2024
FOTILE

FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-LOGO

FOTILE SD2F-P3, SD2F-P3L In Sink Dishwasher

FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-PRODUCT-
IMAGE

Safety Instructions

To avoid injury and property damage to users and other persons, please read and observe all safety instructions and warnings.

  1. The personnel installing this product must have basic mechanical, electrical and plumbing skills. This product must be installed by certified professional plumbers.
  2. It is the responsibility of the installer for correct installation, any product fault caused by improper installation will not be covered by the FOTI LE warranty.
  3. Disconnect the power before installing the product to prevent electric shock.
  4. Do not wet the power cable, power plug, connectors or other electric parts, or it may cause electric shock or other accidental damages.
  5. Do not modify, stretch, knot the power cable or place heavy objects on it. Doing so may cause damage to the power cable and result in electric shock, fire, etc.
  6. Do not touch the power cable or electrical parts with wet hands, or it may cause electric shock.
  7. The Sink Dishwasher must be connected to a grounded electrical outlet. If you don’t have a grounded electrical outlet, please have a certified electrician install one. Failure to do so can result in electrical shock and injury.
  8. If the power cable is damaged, it must be replaced by Fonti le Service Technicians to avoid danger.
  9. During installation, please pay attention to the edges and corners of the sink to avoid scratches.
  10. Only cold water can be supplied to the water inlet of the Fonti le sink dishwasher. Supplying hot water will affect the produce cleaning function for fruits and vegetables. The FOTI LE Sink Dish­washer uses its’ own heating element to heat water for dishwashing.
  11. Do not allow children to play with the plastic film or other packaging components which may cause asphyxiation and possible death.
  12. The countertop which the product is installed into must have sufficient strength to support 220 lbs (100Kg). Please follow all mounting directions to be firmly installed into the countertop correctly.
  13. The countertop which this product is installed into, must be made from temperature and humidity resistant materials.
  14. During product installation, the functional sink must maintain a distance of 11 13/16 “(300mm) or more from the gas meter and the gas pipeline. The junction box must be a distance of 5 15/16” (150mm) or more from the gas meter and gas pipeline.
  15. Please adhere to all local laws and regulations for the connection of the drain hose.
  16. Please save this Installation Manual for future reference.

Installation Requirements

To avoid injury and property damage to users and other persons, please read and observe all safety instructions and warnings.

  1. Objects obstructing the functional sink and drain line such as a gas line or gas meter should not be installed in the cupboard;
    Hose and equipment| Net Distance from Gas Hose
    ---|---
    Parallel Lying| Cross Lying

Electrical equipment

| Exposed insulated wire or cable| 9 7/8″(250mm)| 3 15/16″(100mm)
Exposed wire with voltage less than 1.DDOV| 39 3/8″(1.000mm)| 39 3/8″(1,000mm)
Switchboard or distribution box, electricity meter| 11 13/16″(300mm)| Not allowed
Electrical socket, power switch| 5 15/16″( 150mm)| Not allowed
2. The water supply and power socket should be arranged in the cupboard (or the adjacent cupboard). 3. The 120V/60Hz power supply shall be provided. A wire with a diameter of more than 14AWG should be used and reliably grounded. 4. The pressure of the installation waterway should meet the requirements of 20.3 psi-145.04 psi. 5. Height requirements for drain hose: The height from the top of the installed countertop to the drain hose should be greater than or equal to 21 11/16 “(550mm).
FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-01FOTILE-SD2F-P3-SD2F-P3L-In-
Sink-Dishwasher-01

  1. Opening size of the countertop and size requirements in the cupboard
    Opening size of the countertop| Inner wall size of cupboard
    ---|---
    Length| Length| Length| Length| Length| Length
    33 11/16″| 18 1/8″| 7/16″| e::33 7 / 8 “| e::20 1 / 8 “| e::35 7 / 1 6 “

  2. After the dishwasher is installed, the whole machine can be taken out from the countertop for future maintenance.

  3. There should be at least an 18″ space above the countertop so that the door of the dishwasher can be opened normally.

Installation List

Product Packing Box ListFOTILE-SD2F-P3-SD2F-P3L-In-Sink-
Dishwasher-03

Recommended installation accessories (purchase by oneself)
: Must x: No need o: Optional
FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-04

Recommended installation tools
(please use appropriate tools according to actual installation environment)
FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-05

Installation

  • Product dimensions
    FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-06

Installation steps

  • Step 1: Unpack the unit. Take out the dishwasher from the carton and place it on a temporary level and sturdy surface

  • Step 2: Install water inlet Connect the inlet hose with 3/8″ interface to the joint of the water inlet valve and screw it together.

  • Step 3: Install accessories

1. Take out the rubber hose from the packaging bag and insert one end of the rubber hose into the drip hole under the electrical lock.  

FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-08

2. Put the clamp into the upper end of the electrical lock tee, insert the electrical lock tee into the drop opening of the overflow seat for the functional sink, and lock the clamp.  

FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-09

3. Insert the other end of the rubber hose into the electrical lock tee.  

FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-10

4. Put the clamp into the upper end of the overflow base – exhaust tee, insert the joint pipe of overflow seat and insert the exhaust tee into the drip hole of the overflow base for the sink, then put the overflow base into the exhaust tee, and lock the clamp.  

FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-11

5. Put the clamp into one end of the exhaust pipe, insert into the side hole of the exhaust tee, and lock the clamp.  

FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-12

6. Connect and pre-tighten the drain hose assembly for the functional sink and the drain opening of the functional sink. Ensure there is a gasket at the joint.  

FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-13

7. Put the clamp into the two overflow pipes, insert the shorter one into the drainage opening of electrical lock tee for the functional sink, insert the longer one into the drainage opening of the overflow seat – exhaust tee, and lock the clamp.  

FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-14

  • Step 4: Install the faucet and tee
1. Install the faucet and fasten it.
2. Collect the tee at the angle valve of cold water.
  • Step 5: Clean and glue the countertop
1. Clean and install the countertop
2. Spray glass cement along the perimeter of the mounting hole edges and ensure there is a plenty and continuous supply.  
  • Step 6: Place the sink dishwasher
1. Wear protective gloves and place the sink dishwasher into the opening.  

Note: Do not lift or move the sink dishwasher by the faucet as this will cause damage and possible water leakage.

  • Step 7: Connect water pipes
1. Correctly connect the cold and hot water pipes of the faucet.
2. Connect the water inlet of the sink dishwasher and cold water valve tee, and screw it down.  

Note: Only cold water can be supplied to the water inlet of the dishwasher. 3. Open the angle valve and ensure there is no leakage at each joint.

  • Step 8: Connect power supply
1. Cut off power supply of the electrical box
2. Connect the power cable of the sink dishwasher and the cable in the electrical box, and take the necessary insulation protection measures  

FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-17 Note: The null line and live wire MUST be connected correctly and have a reliable ground.

  • Step 9: Install the drainer or waste disposer Drainer:
1. Correctly install the drainer, connect with the drain hose of the sink dishwasher and ensure tightness and no leakage.  

Note:

  * If the pipeline needs to be shortened, cut C end, cutting length :=;;2″_
  * If the pipeline needs to be lengthened, unscrew the thread of D end and pull it out, pull-out distance ::;;r·.  

FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-18

  * Ensure the drain hose keeps vertical or horizontal state ![FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-19](https://manuals.plus/wp-content/uploads/2022/10/FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-19.png)
  * (Other pipelines of air gap can be connected at A. If there is no such requirement, please seal it or directly use the pipeline without A interface)
  * Kitchen Sink Disposal
    1. Correctly install the kitchen Sink Disposal and ensure it’s is installed in place, without leakage.
    2. Adjust the water outlet of the kitchen Sink Disposal and tightly connect it with the drain hose of the sink dishwasher, without leakage.  

Note:

  * If the pipeline needs to be shortened, cut C end ($;2″).
  * If the pipeline needs to be lengthened, unscrew the thread of the D end and pull it out, pull-out distance $;1″.![FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-20](https://manuals.plus/wp-content/uploads/2022/10/FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-20.png)
  * Ensure the drain hose keeps vertical or horizontal state  

FOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-21(Air Gap or other pipelines can be connected at B. If there is no such requirement, please seal it)

  • Step 10: Check the pipeline
1. Check whether the pipeline connected with the sink has leakage.
2. Check whether the pipeline connected with the functional sink has leakage.
  * Switch on the power supply, Press the open key to open the door and take out all articles in the sink.
  * Press the strength key for a long time to close the valve under the standby (black screen) mode, fill the overflow opening with water, and check the functional sink and the drain hose for leaks.
  * Press the Start/Pause key for a long time to open the valve and drain water, and check each joint of the drain hose for leaks.
  • Step 11: Final Steps

    1. Spray glass cement along the product edge.

    2. Place the filter plate assembly togetherFOTILE-SD2F-P3-SD2F-P3L-In-Sink-Dishwasher-22

    3. Install the spray arm: Pinch the gray locking tab under the spray arm, place it to the position shown in the picture and rotate clockwise. After hearing “click” sound,
      Spin the spray arm and ensure smooth rotation.FOTILE-SD2F-P3-SD2F-P3L-In-
Sink-Dishwasher-23

    4. Installation Complete

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

FOTILE User Manuals

Related Manuals