COMMSCOPE T750SE Ruckus Outdoor Access Point User Guide
- June 5, 2024
- CommScope
Table of Contents
- COMMSCOPE T750SE Ruckus Outdoor Access Point
- Quick Setup Guide
- Before You Begin
- Package Contents
- Mounting Instructions
- Attaching the U-Joint Bracket to the Mounting Bracket
- Connector Sealing Instructions
- Earth Grounding the AP
- Installing the Security Cable
- Troubleshooting
- For More Information
- Federal Communications Commission Notices
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
COMMSCOPE T750SE Ruckus Outdoor Access Point
Quick Setup Guide
- The minimum software revision for the T750SE is ZoneDirector (ZD) 10.4.1 or later, or SmartZone (SZ) 5.2 or later, or standalone AP firmware 114.X or later. This Quick Setup Guide provides step-by-step instructions on how to fieldinstall the RUCKUS WIRELESS T750SE access point (AP).
- For detailed information on planning the installation, performing a site survey, and operating the T750SE, refer to the RUCKUS WIRELESS Outdoor
- Access Point User Guide, available at https://support.ruckuswireless.com
- Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
- Installation of this equipment must comply with local and national electrical codes.
- Make sure that you form a 80mm – 130mm (3”-5”) drip loop in any cable that is attached to the AP or the building. This will prevent water from running along the cable and entering the AP or the building where the cable terminates.
- Be sure that grounding is available and that it meets local and national electrical codes. For additional lightning protection, use lightning rods and lightning arrestors.
- Make sure that proper lightning surge protection precautions are taken according to local electrical code.
- RUCKUS WIRELESS strongly recommends that you wear eye protection before mounting the T750SE
Before You Begin
Before deploying RUCKUS WIRELESSs products, please check for the latest software and the release documentation.
- Release Notes and other user documentation are available at http://support.ruckuswireless.com/documents
- Software upgrades are available at http://support.ruckuswireless.com/software
- Software license and limited warranty information are available at http://support.ruckuswireless.com/warranty. Before deploying your RUCKUS WIRELESS Access Point, verify that all items listed in Package Contents are included in the package. If any item is damaged or missing, notify your authorized RUCKUS WIRELESS sales representative. Also, make sure that you have the required hardware and tools.
Required Hardware and Tools
- 1/2” (13 mm) flat-blade screwdriver or equivalent
- No. 2 Phillips screwdriver
- Small flat-blade screwdriver
- Torque wrench or torque screwdriver with sockets
- Long-nose pliers
- Electrical wire stripping and terminal crimping pliers
- Pipe, pole or a sturdy flat surface
- Electric drill with drill bits and customer-supplied wall anchors, flat washers, and hex nuts for flat-surface mount
Package Contents
A complete T750SE field installation package includes all of the items listed below :
- T750SE Access Point
- M25 data cable gland extender
- Three M25 data cable glands
- Outdoor AP Mounting Bracket kit
- One ground wire with lug
- Cloud Management Statement
- Cable gland extender gasket
- AC Connector
- Zipcord cable gland grommet
- Four 1/2” (12.7 mm) wide adjustable clamps, 2.5” (63.5 mm) diameter, for main mounting bracket on smaller poles
- Safety cable kit
- Service Level Agreement/Limited Warranty Statement
- Declaration of Conformity
- Regulatory Statement
- RUCKUS WIRELESS AP Getting Started Guide
- This Quick Setup Guide
Mounting Instructions
Connecting and Sealing the RJ-45 Cables
The T750SE may use zero, or one or two RJ-45 cables, one for Ethernet when configured as a Root AP (RAP), and another when the T750SE is supplying PoE out to a peripheral device, such as a small cell or micro cell radio, and zero when using the SFP as a backhaul alternate with AC power. When the T750SE uses RJ-45 cables, connect and seal the cables using the M25 data cable glands
T750SE AP PoE IN and PoE OUT ports
- SFP port
- PoE IN
- PoE OUT
- AC port
WARNING! Do not use any PoE injector not tested and approved by RUCKUS
WIRELESS to power the T750SE Access Point.
WARNING! Do not plug PoE IN power into the PoE OUT port. See Figure 1.
Feed the end of the cable through the gland dome, rubber grommet, clamping
ring assembly and cable gland base, as shown in Figure 2.
NOTE: Do not seat the clamping ring and rubber grommet into the cable
gland base until the cable gland base has been torqued to specifications.
T750SE AP PoE IN and PoE OUT ports
- Cable gland base
- Clamping ring
- Rubber grommet
- Gland dome
IMPORTANT INSTRUCTION
- Feed the end of the cable through the gland dome, rubber grommet, clamping ring assembly and cable gland base, as shown in Figure 2.
- Use a wide flat-blade screwdriver to remove the required (PoE OUT or PoE IN) blanking cap from the T750SE.
- Connect the cable to the Ethernet port in the AP.
- Tighten the cable gland base to 7 N.m (62 in-lbs).
- Wrap the clamping ring assembly around the rubber grommet. Make sure that the clamping ring assembly fully encloses the rubber grommet.
- Seat the clamping ring assembly and rubber grommet in the cable gland base.
- Hand-tighten the gland dome.
Connecting the SFP Optic Module Using a Single Diameter Cable
You can use a single diameter cable to connect to the SFP optic module.
SFP module cable gland assembly
- SFP transceiver
- Cable gland gasket
- Cable gland extender
- Cable gland gasket
- Clamping ring
- Cable gland grommet / zipcord cable gland grommet
- Gland dome
- Fibre cable
WARNING! The fiber cable is extremely fragile and must be handled with
care.
NOTE: Do not insert the cable gland base/grommet/dome into the extender
until the extender has been tightened. Step 5 must be performed before Step 6,
else the fiber cable will twist.
- Place the cable gland base to the cable gland extender and tighten the cable gland base to 7 N.m (62 in-lbs).
- Fix the Cable gland extender gasket to the cable gland extender.
- Feed the fiber cable through the gland dome, cable gland grommet, clamping ring, cable gland base, cable gland extender, and cable gland gasket as shown in Figure 3.
- Connect the fiber cable to the SFP transceiver in the AP.
- Tighten the cable gland extender to 7 N.m (62 in-lbs).
- Insert the cable gland grommet into the clamping ring with the fiber cable in the center.
- Insert the clamping ring into the cable gland base.
- Tighten the cable gland dome to 7 in-lbs. The SFP module is hot-swappable and can be removed with fingers or simple tools
Connecting the SFP Optic Module Using a Zipcord Cable
You can use a zipcord cable to connect to the SFP optic module.
WARNING! The zipcord fiber cable is extremely fragile and must be handled
with care.
NOTE: Do not insert the cable gland base/grommet/dome into the extender
until the extender has been tightened. Step 5 must be performed before Step 6,
else the fiber cable will twist.
- Place the cable gland base to the cable gland extender and tighten the cable gland base to 7 N.m (62 in-lbs).
- Fix the Cable gland extender gasket to the cable gland extender.
- Feed the zipcord fiber cable through the gland dome, zipcord cable gland grommet, clamping ring, cable gland base, cable gland extender, and cable gland gasket as shown in Figure 3.
- Connect the zipcord fiber cable to the SFP transceiver in the AP.
- Tighten the cable gland extender to 7 N.m (62 in-lbs).
- Insert the zipcord cable gland grommet into the clamping ring with the zipcord fiber cable in the two holes
- Insert the clamping ring into the cable gland base.
- Tighten the cable gland dome to 7 in-lbs. The SFP module is hot-swappable and can be removed with fingers or simple tools.
Attaching the U-Joint Bracket to the Mounting Bracket
-
Position the U-joint bracket on the mounting bracket.
NOTE: Mount the U-joint bracket in any direction on the mounting bracket, preferably to allow AP azimuth adjustments. Then the AP bracket allows AP elevation adjustments. -
Use four 1/4 – 28 bolt and washer sets (1) to mount the U-joint bracket (2) to the mounting bracket (3). Tighten the bolts to 9.5 N.m (84 in-lbs).
-
Continue with Attaching the Mounting Bracket to a Flat Surface on page 3.
Attaching the Mounting Bracket to a Flat Surface
- Place the mounting bracket at the location on the flat surface where you want to mount the AP. Use the holes on the mounting bracket as a template to mark the locations of the mounting holes.
- Remove the mounting bracket from the flat surface.
- Drill holes required for the mounting hardware.
- Attach the mounting bracket to the flat surface using the mounting hardware.
- Using the mounting hardware instructions, tighten the hardware to secure the mounting bracket.
- Continue with Attaching the Mounting Bracket to a Pole on page 3.
Attaching the Mounting Bracket to a Pole
-
Insert the open end of one steel clamp into the upper two slots on the mounting bracket.
-
Take the other steel clamp and insert it into the lower two slots on the mounting bracket
NOTE: The clamps can be daisy-chained together to accommodate larger poles. -
Use the clamps to attach the mounting bracket to the pole. Tighten the clamps to 3 N.m (27 in-lbs) or per manufacturer’s specifications.
-
Continue with Mounting the Linkage Bracket to the U-Joint Bracket on page 3.
Mounting the Linkage Bracket to the U-Joint Bracket
-
The linkage bracket attaches to the U-joint bracket using an M8 bolt and washer set. The linkage bracket is symmetrical, and either end can be attached to the U-joint bracket.
NOTE: Make sure that linkage bracket is installed with its serrated external-tooth lock washer on the inside of the U-joint bracket flanges. This ensures that the azimuth adjustment does not change. -
Loosely assemble the linkage bracket (1), the U-joint bracket (3), one serrated external-tooth lock washer (2), and one M8 bolt and washer set (4).
-
M8 bolt
-
Lock washer
-
Flat washer
-
External-tooth lock washer
-
Linkage bracket
-
U-joint bracket
-
Set the azimuth required by the AP.
-
Tighten the M8 bolt to 13.6 N.m (120 in-lbs).
-
Continue with Attaching the AP Bracket to the Linkage Bracket on page 3.
Attaching the AP Bracket to the Linkage Bracket
Attach the AP bracket to the linkage bracket using the included bolt, lock washer, flat washer, serrated external-tooth washer and nut shown in the illustration below. The linkage bracket is symmetrical, and either end can be attached to the AP bracket. Loosely assemble the AP bracket to the linkage bracket using the M8 bolt, washer and nut set.
Attach the linkage bracket to the AP bracket
- M8 bolt
- Locker washer
- Flat washer
- External-tooth lock washer
- Linkage bracket
- AP bracket
- Nut
NOTE: Make sure that the linkage bracket is installed with its serrated external-tooth lock washer on the inside of the AP bracket flanges. This ensures that the elevation adjustment does not change.
Attaching the AP Bracket to the Access Point
-
Place the AP bracket onto the back side of the AP so that the four larger screw holes on the bracket align with the four screw holes on the
-
AP
-
AP bracket
-
Flat washer
-
Lock washer
-
Hex bolts
-
Use four 0.5-inch x 0.250-28 hex bolts with split lock and flat washer sets to mount the AP bracket to the AP. Tighten the bolts to 2.5-3.0 N.m (22-27 in-lbs).
CAUTION! Make sure that the screws are no longer than 0.5 inch. If a screw is longer than 0.5 inch, it can damage the AP chassis.
NOTE: This kit may include extra screws, nuts and washers. You may use the extras where required. -
Continue with Set the Elevation and Tighten the Elevation Bolt on page 4.
Set the Elevation and Tighten the Elevation Bolt
- Set the elevation required by the AP.
- Tighten the M8 bolt to 13.6 N.m (120 in-lbs).
- Continue with Powering the AP with AC on page 7.
External Antenna and Cabling Need to be Purchased Separately
If the External Antenna option is chosen over the internal sector antenna, the
External Antenna and Antenna Cable must be purchased separately.
NOTE: Beamflex is not available with external antennas.
Mounting and Connecting 5 GHZ and 2.5 GHZ External Antennas
NOTE: Mount the external antenna per manufacturer’s instructions.
- Disconnect the AP from all power sources.
- Unscrew the metal caps that protect the antenna connectors.
- Connect external antennas to the N-type female antenna connectors on the AP. Use a torque wrench to tighten the connectors to 1.58 N.m (14 in-lb).
- If the antennas come with RF coaxial cables (for example, a patch antenna), physically mount the antennas at your desired location, preferably on the same mounting structure as the AP.
- Apply weatherproofing tape to the antenna connectors as described in Connector Sealing Instructions on page 5.
CAUTION! If you are not connecting external antennas to the AP, make sure that the metal caps remain installed and securely fastened to protect the interfaces from elements, such as water and dirt.
Connector Sealing Instructions
NOTE: N-Type connectors shown are representative examples.
NOTE: Applying sealing tape to both ends of the cable is recommended.
Step 1: Cleaning the Connectors and Your Hands
- Clean all traces of dust, grease, and oil from your hands
- Clean off any traces of dust, grease, and oil from the N-type bulkhead connector external threads
- Make sure that the connectors are dry before continuing.
Step 2: Connecting the Cable with the Connector
-
If the AP is powered on, disconnect the AP from the power source.
CAUTION! Make sure that you disconnect the AP from the power source to avoid electrocution or equipment damage. -
Unscrew the metal cap that protects the antenna connector. Place the metal cap in a safe place, in case you need it later.
-
Connect the cable to the connector. Use a torque wrench to tighten the cable coupling nut to 1.58 N.m (14 in-lb). If you do not have a torque wrench or if you are tightening a knurled coupling nut (as shown), hand-tighten the cable coupling nut until the internal gaskets are compressed but do not overtighten.
Step 3: Wrapping the Exposed Connector Threads
- Depending on the width of the sealing tape, either fold the tape in half or cut it to fit the exposed connector threads
- Stretch the tape per the manufacturer’s instructions
- Working clockwise, gently stretch the sealing tape as you install it so that it covers the connector thread between the cable coupling nut and the base of the connector.
Make sure that the final wrap is approximately flush with the cable coupling nut, and then cut the sealing tape. NOTE: Cut, do not tear, the sealing tape. If the sealing tape is overstretched, it loses its self-amalgamating properties.
Step 4: Wrapping the Internal Layer of the Electrical Tape
- Using scissors, cut the end of the electrical tape at an angle. This will allow the electrical tape to be applied with minimal bulk. FIGURE 14 Cutting the End of the Electrical Tape
- Working clockwise, gently stretch the sealing tape from the beginning coupling nut to just past the heat shrink tube on the cable. Do not cover the sealing tape installed in Step 3: Wrapping the Exposed Connector Threads on page 5.
Step 5: Wrapping the Main Sealing Tape
-
Using scissors, cut the end of the sealing tape at an angle. This will allow the sealing tape to be applied with minimal bulk.
-
Working clockwise, gently stretch the sealing tape from the beginning of the sealing tape installed in Step 3: Wrapping the Exposed Connector Threads on page 5 and continue wrapping to 12 mm (0.5 in.) past the electrical tape installed in Step 4: Wrapping the Internal Layer of the Electrical Tape on page 5.
NOTE: Cut, do not tear, the sealing tape. If the sealing tape is overstretched, it loses its self-amalgamating properties. -
Gently knead the sealing tape from top to bottom to make sure there are no gaps and to amalgamate the sealing tape.
Step 6: Wrapping the Outer Layer of Electrical Tape
- Using scissors, cut the end of the electrical tape at an angle. This will allow the electrical tape to be applied with minimal bulk.
- Wrap the electrical tape clockwise to completely cover the sealing tape and continue wrapping to 12 mm (0.5 in.) past the sealing tape installed in Step 5: Wrapping the Main Sealing Tape on page 5.
Step 7: Repeating for the Other Cables
Repeat the connector sealing instructions for the three antenna connectors, as
shown in Figure 18.
Step 8: Creating Cable Drip Loops
Physically mount the AP and antennas at your desired location, preferably on
the same mounting structure.
Form 80-mm to 130-mm (3-in. to 5-in.) drip loops with the cables.
Earth Grounding the AP
CAUTION! Make sure that earth grounding is available and that it meets
local and national electrical codes. For additional lightning protection, use
lightning rods and lightning arrestors.
NOTE: The color coding of ground wires varies by region. Before
completing this step, check your local wiring standards for guidance.
Using the factory-supplied ground wire and ground screw/washer set, connect a
good earth ground to the AP chassis ground point.
CAUTION! The T750SE AP includes one 9 mm stainless steel M6 x1 earth
ground screw with split lock and flat washers. Make sure that any replacement
screw is no longer than 9 mm. If a screw is longer than 9 mm, it can damage
the AP chassis.
- Earth ground screw
Congratulations! You have mounted your T750SE access point.
Powering the AP with AC
-
Separate the AC cable connector parts by unscrewing the boot from the cable gland and the cable gland from the connector housing..
-
Feed the end of the AC cable through the boot and cable gland.
-
Strip the AC cable as shown.
-
Insert the stripped part of the conductors into the appropriate terminals on the connector housing. The conductors are color coded and must be connected to the appropriate terminals as shown in figure below.
NOTE: The color coding of wire conductors varies by region. Before completing this step, check your local wiring standards for guidance.
Wire Stripping (Not Actual Size) -
(Neutral/Return): White or Gray (US), Blue (EU)
-
(Line/Hot): Black (US), Brown (EU)
-
(not used)
-
(Earth Ground): Green (US), Green/Yellow (EU)
-
Using a small screwdriver, tighten the small screws around the connector housing to fix the connector pins into the terminals.
-
Mate the cable gland with the connector housing, and then handtighten.
NOTE: Two different-sized grommets are supplied in the AC connector assembly kit. Use the grommet that is appropriate to the diameter of the AC cable that you are using. -
Mate the boot with the cable gland, and then hand-tighten to seal.
-
Connect the AC cord connector that you have assembled to the AC power socket on the AP.
-
Connect the AC cord to an AC power source.
Installing the Security Cable
- Thread the security cable through the mounting bracket (1 in Figure 12) and through the eye on the cable itself (2 in Figure 12).
- Attach the safety cable to the AP (3 in Figure 12).
Troubleshooting
CAUTION! If required, you can reset the AP to its factory default settings by pressing the reset button located inside the PoE IN port. Use the tip of a pen or a 3mm flat blade screwdriver to press the reset button. Press and hold the reset button for 4+ seconds to restore to factory defaults. DO NOT RESET THE AP TO FACTORY DEFAULT SETTINGS UNLESS SO INSTRUCTED. (Doing this resets the AP IP address to 192.168.0.1.)
NOTE: After a reset, you can access the internal AP web interface using https://192.168.0.1. Your device must use any other address from 192.168.0.2 through 192.168.0.254, with subnet mask 255.255.255.0. The username is super, and the password is sp-admin. Refer to the Outdoor Access Point User Guide for information on configuring and operating the AP. This document is available at https://support.ruckuswireless.com.
For More Information
For information on how to configure and manage the AP, refer to the RUCKUS
Access Point User Guide, available from https://support.ruckuswireless.com.
RUCKUS WIRELESS, Inc. is a wholly owned subsidiary of CommScope, Inc.
© 2020 CommScope, Inc. All rights reserved.
ARRIS, the ARRIS logo, COMMSCOPE, RUCKUS, RUCKUS WIRELESS, the Ruckus logo,
and the Big Dog design are trademarks of CommScope, Inc. and/or its
affiliates. Wi-Fi Alliance, Wi-Fi, the Wi-Fi logo, Wi-Fi Certified, the Wi-Fi
CERTIFIED logo, Wi-Fi Protected Access, the Wi-Fi Protected Setup logo, Wi-Fi
Protected Setup, Wi-Fi Multimedia and WPA2 and WMM are trademarks or
registered trademarks of Wi-Fi Alliance. All other trademarks are the property
of their respective owners.
T750, T750SE – Outdoor Enterprise AP
Federal Communications Commission Notices
This product complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Caution: Changes or modifications to this equipment that have not been
approved by Ruckus Wireless may void the user’s authority to operate this
equipment.
For Class B Equipment:
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Industry Canada Statement
Under Industry Canada regulations, this radio transmitter may only operate
using an antenna of a type and maximum (or lesser) gain approved for the
transmitter by Industry Canada. To reduce potential radio interference to
other users, the antenna type and its gain should be so chosen that the
equivalent isotropically radiated power (e.i.r.p.) is not more than that
necessary for successful communication.
Operation in the 5600-5650 MHz band is not allowed in Canada. High-power
radars are allocated as primary users (i.e. priority users) of the bands
5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference
and/or damage to LE-LAN devices.
Radiation Exposure Statement
The device has been found to be compliant to the requirements set forth in CFR
47 Sections 2.1091 and Industry Canada RSS-102 for an uncontrolled
environment. The antenna(s) used for this transmitter must be installed to
provide a separation distance of at least 20 cm from all persons and must not
be co-located or operating in conjunction with any other antenna or
transmitter.
Professionally Installed Products
The product is to be installed according to the installation instructions. The
Use/Operator does not have access to the device once the device is installed
and in use. Provisions for permanent grounding is provided.
-
Installation personal: This product is designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge. The general user shall not attempt to install or change the setting.
-
Installation location: The product shall be installed at a location where the radiating antenna can be kept 20 cm from nearby person in normal operation condition to meet regulatory RF exposure requirement. Additionally, installation locations with 35km of Terminal Doppler Weather Radar locations shall follow instructions below.
a. Any installation of either a master or a client device within 35 km of a TDWR location shall be separated by at least 30 MHz center-to-center) from the TDWR operating frequency.
b. A voluntary WISPA sponsored database has been developed that allows operators and installers to register the location information of the UNII devices operating outdoors in the 5470 5725 MHz band within 35 km of any TDWR location (see http://www.spectrumbridge.com/udia/home.aspx ). This database may be used by government agencies in order to expedite resolution of any interference to TDWRs.
c. Addition information can be obtained from the FCC Knowledge Database, Publication Number 443999. https://apps.fcc.gov/oetcf/kdb/index.cfm -
External antenna: Use only the antennas which have been approved by Ruckus Wireless. The non-approved antenna(s) may produce unwanted spurious or excessive RF transmitting power which may lead to the violation of FCC limit and is prohibited.
-
Installation procedure: Please refer to user’s manual for the detail.
-
Warning: Please carefully select the installation position and make sure that the final output power does not exceed the limit set force in US Rule CFR 47 part 15 section 15.247 & 15.407. The violation of the rule could lead to serious federal penalty.
Medical Statement
Ruckus Wireless Access Points shall only be used in ME systems where the
intended EM ENVIRONMENT does NOT does not rely on the WLAN radio link for
BASIC SAFETY or ESSENTIAL PERFORMANCE of the ME SYSTEM.
Australia and New Zealand Statement
This device complies with the ACMA requirements for a WiFi device namely
Radiocommunications (Low Impact Potential Devices) C lass Licence 2000 Amd.
1:2007 and Radiocommunications (Compliance Labelling – Electromagnetic
Radiation) Notice 2003 and the New Zealand Radiocommunications Regulations
(General User Radio Licence for Short-Range Devices). The equipment complies
with the ACMA and New Zealand requirements for radiation exposure for a
“general user/non-aware user”. This equipment should be installed and operated
with a minimum distance of 20 cm between the radiator and your body. This
equipment complies with the Australian and New Zealand safety requirements and
should only be used with the specified power adapter carrying a C-tick mark
and Electrical Approval No.
Brazil Statement
For Brazil, those products are designed for specific application and needs to
be installed by a qualified personal who has RF and related rule knowledge.
Regarding the operation on range of 5150 MHz to 5350 MHz, the average output
power of the equipments must be adjusted to the maximum limit of – 0,48 dBm
and for 5470 MHz to 5725 MHz, the average output power of the equipments must
be adjusted to the maximum limit of 6,44 dBm
Hong Kong Statement
The 5.15 – 5.35 GHz band shall be restricted to indoor operations only. Obey
local regulations when using this product.
European Union Notices and National Restrictions
EU Declaration of Conformity
This declaration of conformity is issued under the sole responsibility of the
manufacturer (or installer): Ruckus Wireless, Inc. – 350 West Java Drive,
Sunnyvale, CA 94089 USA
+1-650-265-4200
The object of the declaration is in conformity with Directive 2014/53/EU of
the European Parliament and of the Council of 16 April 2014 and Directive
2011/65/EU of the European Parliament and of the Council of 8 June 2011 on the
harmonisation of the laws of the Member States relating to the making
available on the market of radio equipment. The following standards were
applied during the assessment of the product:
- Radio: ETSI EN 300 328, ETSI EN 301 893, ETSI EN 302 502, EN 303 413
- EMC: EN 55032, EN 301 489-1, EN 301 489-17, EN 301 489-19
- Safety: IEC/EN/UL 60950-1, IEC/EN/UL 62368-1, EN 62311, EN 50385, EN 50665
The frequency band 5150 – 5350 MHz is restricted to indoor use. The frequency band 5725 – 5875 MHz are non-harmonized frequencies. Use is restricted to outdoor professionally installed access points as allowed by local authorities. AT FI IT PL UK RO
Maximum output power:
- 2400-2483.5MHz: 19.9dBm EIRP
- 5150-5350MHz: 22.9dBm EIRP
- 5470-5725MHz: 29.9dBm EIRP
- 5725-5875MHz: 35.9dBm EIRP
Hereby, Ruckus Wireless Inc., declares that the radio equipment types T750 and
T750SE is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following internet address: https://www.commscope.com/product-type
/enterprise-networking/wi-fi-access-points-accessories/outdoor/t750/
Hereby, Ruckus Wireless declares that this Radio LAN is in compliance with the essential requirements and other relevant prov isions of Directive 2014/53/EU.
T750 & T750SE, Access Point Installation Addendum
When the frequency band 5150 – 5250 MHz is used outdoors in the U.S.A, the FCC
mandates that the energy radiated above 30° from the horizon remains below 21
dBm EIRP. This can be maintained during installation using the following
guidance.
When the device is installed level to the horizon, (i.e. – device
perpendicular to the surface of the earth, antenna radome pointing horizontal,
parallel to the earth), the device operates in compliance with FCC rules
without any adjustment of output power.
T750 & T750SE – Antennas
When the device is installed outdoors at an angle above the horizon, it may be
necessary to reduce output power to insure the energy radiated above 30° from
the horizon remains under 21 dBm EIRP.
References
- Ruckus Wireless Support
- Ruckus Wireless Support
- Technical Documents | Ruckus Wireless Support
- Software Downloads | Ruckus Wireless Support
- Warranty for Wired and Wireless Products | Technical Documents | Ruckus Wireless Support
- 192.168.l.l - 192.168.1.1 Admin Login
- OET Knowledge Database (KDB)
- Ruckus Wireless Support
- Ruckus Wireless Support
- 0C64EFC4-860C-49F0-99F5-372FE557F13F
- 0C64EFC4-860C-49F0-99F5-372FE557F13F