Yoshikawa Kogyo Workers Approach Warning System User Manual

June 5, 2024
Yoshikawa Kogyo

Yoshikawa Kogyo Workers Approach Warning System

About this system

Be sure to read this section before use.

  • This system can provide only warnings to drivers and workers, and the braking operations such as braking of vehicles must be performed by the driver.
  • It is impossible for this system only to prevent all accident. You must confirm the safety by sight as before.
  • Consult with us if you have a heart pacemaker or a medical device such as a life support device installed.
  • Radio wave interference in the surrounding area may cause the range of radio waves to change.
  • We recommend measuring the radio wave environment in advance in the vicinity of electronic devices, power supply panels, cranes, and other heavy equipment.
  • The detection range varies depending on the installation environment and surrounding conditions.
  • After installation, confirm that the unit is operating correctly by following the operation check procedure.
  • Confirm proper operation according to the daily inspection procedure in the User’s Manual.
  • Use in extremely high or low temperatures may cause malfunction or failure. Use within the operating temperature.
  • Due to legal restrictions, this product is prohibited from being used for applications other than those related to Safety operation of the vehicle.
  • It is illegal to disassemble or modify TAGs.
  • Specifications and appearance are subject to change without notice for improvement.
Line-up
No. Model Name Model number Power supply voltage Detection range Note
 1  DETECTOR  YS-F-R023A  DC 48V  3~8m Power supply cable 5m included

(stripped on one side)
3| Speaker| YS-F-S003A| | | Up to 87dB, IP54
4| Indicator lamp| YS-F-V027A-R| | |
No.| Model Name| Model number| Alarm function| Batteries| Note
---|---|---|---|---|---
5| ALERT-TAG| YS-F-T003A| Vib & Buzzer| AAA 2pcs| In the pocket or waistbelts
6| STANDARD-TAG| YS-F-T008A| None| CR2032| Attached on the helmet.

Glossary

Term Meaning
1 Detector It has a transmit function by a magnetic field, and an alarm

function by receiving a radio signal from a TAG.
2| TAG| It has a function to receive the magnetic field from the detector and a function to transmit radio waves.
ALERT-TAG has a function to alert you.
3| Magnetic field| The magnetic field transmitted by the detector uses the 125kHz band.
Stable sensing distance is achieved by using a magnetic field.
4| Radio waves| The radio waves transmitted by the TAG use the 315MHz band.
Transmitting radio waves from the TAG to the detector enables the detector to alert.
7| IP65| They are used to define levels of sealing effectiveness of electrical enclosures against intrusion from foreign bodies (tools, dirt etc.) and moisture. As defined by International Standard EN 60529.
IP6 [0 to 6] Dust-proof
6: Dust does not enter the inside. IP
5 [0 to 8] Waterproof
5: low-pressure jets (6.3 mm) of directed water from any angle
10| Radio wave noise| Noise that affects the radio waves received by the detector.
In places where radio noise is present, the sensing distance that the detector alarms may be shortened.
11| Magnetic field noise| Noise affecting the magnetic field received by the TAG.
In places where magnetic field noise is present, the detection distance of the TAG may be shortened.
Ex. the power distribution boards, factory equipment and large motors.
12| dB| Indicates the unit of sound volume. Ex.

  • 90dB: Bulldozer, etc. in a noisy plan
  • 110dB: Automobile horn, etc.

What is Worker Approach Warning System?

This is a system that alerts people and vehicles to “dangerous situations” , when they are in close proximity with the technology of magnetic fields and electromagnetic waves.

  1. A magnetic field (125KHz) is being transmitted from the detector.
    The direction of the magnetic field is transmitted in all directions by 360°, and the transmission range is an oval shape with the largest longitudinal direction.

  2. Radio waves (315MHz) including “Detection signal” and “Magnetic field strength” are transmitted from the TAG in the area where the magnetic field from the detector reaches (max. 8m).

  3. The detector sounds an alarm by determining the distance based on the magnetic field strength from the TAG.
    If you use ALERT-TAG, you can also alert from a TAG.

Notes

  • Detection range
    The detection area is 360 degrees in an oval.
    The oval shape depends on the orientation of the detector.
    Depending on the vehicle shape and environment, the detection area may not be an oval.

  • Maximum detection range (e.g., 8m version outside detection range)
    Long side direction of the detector case: Set distance
    Short side direction of the detector case:
    Approx. 80% of the set distance

  • Distance Attenuation in the Environmental conditions
    The sensing distance may be slightly reduced depending on the environmental conditions (effects of magnetic field noise or radio wave noise, structure of the building including reinforcement, etc.).
    e.g. 8m → may be reduced to 6m.
    In this case, the setting of the detection distance by dialing decreases proportionally

DETECTOR (YS-F-R023A)

Vent filter
Do not touch it , because it is necessary to maintain the waterproof property.
Fuse Use a mini glass tube fuse φ5mm 2A.
Power Indicator Green lights up when the detector is turned on.
Select RANGE switch The maximum detection range can be set.
Select ALERM switch Change the alert sound .

Antenna
The radio signal receiving antenna is connected.
Power connector (red)
Connect the power cable (red).
Speaker connector (green)
Connects the speaker (green).
Indicator Lamp connector (Blue)
Connect the Indicator lamp (yellow)

If the indicator lamp is not used,
be sure to attach a protective cap to prevent dust into the unit.

  • STANDARD-TAG (YS-F-T008A)

The operator carries it.

  • Alert function: None (The TAG itself does not alert)

  • Wearing the watch: Mounting the helmet or storing it in a pocket

  • Dust-proof/waterproof type : IP65

  • ALERT-TAG (YS-F-T003A)

The operator carries it.

  • Alarm Function: Required (Vibration, Sound, Light)
  • Mobile method: Pocket and waistbelts

AREA Action
Near the vehicle Stop the alert
Far from vehcle Low Battery LED
Blink OFF
Enough Empty

Alarm action

~ Alarm function ~

  • When the operator enters the detection range of the vehicle, the speaker (or indicator lamp) connected to the detector alarms. If a tag with an alarm function is used, an alarm will be sent from the tag at the same time.
  • The alarm goes out of the detection range and stops after about 2 seconds

~ For Tags with Alarm Function ~

~ For Tags without Alarm Function ~

Specification

  • DETECTOR
Model number YS-F-R023A
Supply Voltage DC48V
power consumption 48W
Operating Temperature -10~+60℃
Detection Range 8m
Transmission frequency 125KHz
Receive frequency 315MHz
Dustproof and water resistant IP65
Dimension W150×D200×H76(mm)
  • Speaker
Model number YS-F-S003A
Supply Voltage DC12-24V
power consumption 3.5W
Maximum Volume 87dB
Dustproof and water resistant IP54
Weight 300g
Dimension W11×D605×H90(mm)
  • Indicator lamp
Model number YS-F-V027A-R
Supply Voltage DC9V
power consumption 2.8W
Lighting Mode Rotation 3type, Blinking 2type, Flashing 5type
Dustproof and water resistant IP65
**** Dimension φ100×H 139(mm)(Lighting area φ100×91.9mm)
Operating Temperature -10°~+60℃
  • TAGs
Model number STANDARD YS-F-T008A ALERT YS-F-T003A
**** Battery Coin Battery (CR2032) AAA Battery ×2
Battery life (Operating time) About a year About a year
Operating Temperature -10~+50℃ -10~+50℃
Transmission frequency 315MHz 315MHz
**** Alarm mode **** No Buzzer & Vibration
Low battery LED yes yes
Dustproof and water resistant **** IP65 equivalent
Weight 25g 100g
Dimension W, D, H 40×67×12.3 66.5×92×21
  • DETECTOR (YS-F-R023A)


  • STANDARD-TAG (YS-F-T008A)

  • ALERT-TAG (YS-F-T003A)

FCC CAUTION

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.

Note:
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

No. Model Name Model number FCC ID
1 DETECTOR YS-F-R023A 2AWRK-YS-RA0848
2 Speaker YS-F-S003A Out of scope
3 Indicator lamp YS-F-V027A-R Out of scope
4 STANDARD-TAG YS-F-T008A 2AWRK-YS-KT008 (Original)
5 ALERT-TAG YS-F-T003A 2AWRK-YS-KT008 (Variant)
6 Thin-ALERT-TAG YS-K-T010 Out of scope