Cardinal Scale SLIMTALKXLBT SlimTalkBT Scale User Manual
- June 5, 2024
- Cardinal Scale
Table of Contents
SLIMTALKXLBT SlimTalkBT Scale
Scale SLIMTALKXLBT SlimTalkBT Scale
User Manual
ModelNo: SLIMTALKXLBT
FCC ID: 2AWG7-SLIMTALKXLBT
Operation flow
Fook Tin Technologies Ltd.
©2017 Fook Tin Technologies Ltd. All Rights Reserved.
SlimTalk Scale Operation Flow
Revision History:
Date | Rev. | Item | By |
---|---|---|---|
8-Jul-20 | 0 | Add BLE feature | Randy |
Features
1.1 Weight capacity: 550lb/0.1lb 250kg/0.1kg
1.2 Sensor on weight: 5kg/11lb
1.3 Overload: 105% of capacity
1.4 Indicator of overload: Err
1.5 Auto-off time:
- Showing 0.0: 10s
- Weight is locking: 10s
- Unstable weight: 30s
1.6 Low battery detection: Lo
Key/Switch Assignment
[UNIT] – Press to change the unit lb /kg (default: lb)
[LANGUAGE] – Switch to select English, Spanish, or disable
LCD Outlook
Operation
Notes: For the very first time the scale is used, you must tap the scale
to see 0.0 on the display, and you need to wait 10 seconds for it to turn off.
Then you can start using the scale normally by just standing on it to display
or speak your weight.
4.1 Open SlimTALK APP on mobile phone. There are two red dashes on the
screen.
4.2 Step on the scale, the two red dashes on a mobile phone will become green. It means a BLE connection is established.
4.3 On the scale, the weight value will blink 3~4 times then lock, and at the same time, the scale speaks the weight if the language is selected. On a mobile phone, it shows the weight at the same time.
4.4 Step off the scale, the reading will keep showing for around 10 seconds, then auto turns off with a voice. And SlimTALK APP will go back to two red dashes.
Remark:
- The weight unit can be changed by pressing the button on the back of the scale.
- The language spoken can be changed by using the switch on the back of the scale.
FCC statements:
The device has been evaluated to meet general RF exposure requirements, The
device can be used in portable exposure conditions without restriction This
device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications or changes to this
equipment. Such modifications or changes could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.