Scanstrut Rokk Wireless Edge 10W SC-CW-05F User Manual

June 5, 2024
SCANSTRUT

29-09-2021 (Issue 1)
ROKK Wireless – Edge 10W (SC-CW-05F
User Manual

Technical information

Input voltage range :
Input current max:
Output power:
Standby current draw:
Waterproof rating:
Certifications:| 10-30V DC (12/24V system)
2A
10W (9.1V, 1.1A)
< 0.1W
IPX6 front and back
Qi, CE, FCC, ROHS,
UNECE R10 E24, C-Tick, UKC
---|---

For latest tech info visit: www.scanstrut.com/rokk- wireless

READ IMPORTANT SAFETY INFORMATION LEAFLET BEORE INSTALLINGScanstrut Rokk
Wireless Edge 10W SC CW 05F - figScanstrut Rokk Wireless Edge 10W SC CW 05F -
fig2

  1. Select optimum mounting locatio

  2. Check viewing angle (a), full jaw extension (b) and 90° adjustability (c)Scanstrut Rokk Wireless Edge 10W SC CW 05F - fig4

  3. Cut out drill template, check alignment and stick down.

  4. – Drill Ø6mm (0.24”) hole in the centre.
    – Drill 3 pilot holes (see tools required table
    – page 1).

  5. – Lightly de-burr 6mm (0.24”) hole.
    – Feed wire through hole.
    – Rotate to Landscape
    – Apply sealant to 3 x holes.
    – Evenly screw the mount into place.

  6. Connect wires to 12/24V supply, ensuring a waterproof connection. Fuse according to input voltage and current.

USER GUIDE:
Place device centrally within the ROKK Wireless Edge jaws.
CARE : wash down carefully with fresh water.

Scanstrut Rokk Wireless Edge 10W SC CW 05F - fig9

Smart LED light guide:

Solid red
Product has power and ready to charge.
Solid green
Product charging.
Flashing red

  1. Foreign object detection: metallic object placed on top that is not Qi compatible.
    or

  2. Thermal cutout: internal temperature is too high/ low.
    Wait for product to return to operating temperature.

Flashing green/red
Input current is too low.

This product is designed to securely mount phones under normal usage conditions. The enduser is entirely responsible for conditions in which their device is used. See  WARRANTY section for further details.
Scanstrut recommends installation is carried out by a qualifi ed electrician. No liability is accepted for damage and/or injury caused by incorrect installation.
WARNING:
This product is to be connected to a 12V DC or 24V DC battery power source only.
The power supply must be switched off before installation.
An appropriate fuse or circuit breaker must be used between the battery / power source and this product. Check for correct polarity of all wiring before switching the power on.
This product may contain high voltages. Do not tamper with the product.
This product is NOT approved for use in hazardous/fl ammable atmospheres. Do NOT install in a hazardous/fl ammable atmosphere e.g. engine room.
Before drilling any holes, ensure the area behind the mounting location is clear of wires, fuel and all other hazardous objects.
Ensure any holes cut will not signifi cantly weaken the structure of the mounting surface.
If the product needs to be mounted outside, it must be mounted in a location safely above the waterline, where it is not at risk of being submerged.

IN EXTREME USAGE ENVIRONMENTS PERFORMANCE MAY VARY.
CAUTION:
The product is designed specifically for the charging of Qi compatible devices.
The cable must be retained and not interfere with mechanical systems.
This product contains no user serviceable components. Do NOT attempt to repair or alter the product in any way.
This product will charge through non-metallic phone cases up to ~3mm thick. Phone cases may alter overall charge performance.
When used in a very high/low ambient temperature/direct or prolonged sunlight the product may temporarily shut down, this is a safety feature of the electronics.
The IP rating is only valid if correctly installed as per these instructions and on a perfectly fl at, nonporous, smooth surface.
When selecting a mounting location, avoid places exposed to heat-radiating appliances and poorly ventilated areas.
EMC INSTALLATION GUIDELINES:

Scanstrut products conform to Electromagnetic Compatibility (EMC) regulations, to ensure that
electromagnetic interference between equipment is minimised.
Correct installation is required to ensure that electromagnetic
interference is kept to a minimum.
WIRING:
When extending the cable from battery/power source to the product, ensure there is consistently a
minimum of 10V being provided to the product. A wire gauge of 18AWG (0.82mm2) is recommended
for any length of cable extension.
The schematic in step 6 is to illustrate how the product should be connected to a 12V DC or 24V DC
battery/power supply.
ENVIRONMENTAL PROTECTION:
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for recycling advice.
IMPORTANT:
Scanstrut Ltd. accepts no responsibility for any injuries or other damages arising from the use of their products in any circumstances.
WARRANTY:
A 2 year, non-transferrable warranty covers this Scanstrut product only and not any devices that are mounted in it or on it. No warranty is given for users’ devices and users  expose their devices to hazards, known or unknown, at their own risk.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

SCANSTRUT User Manuals

Related Manuals