Chiyu Technology CSS-M-V1 Face Recognition Controller Installation Guide
- June 5, 2024
- Chiyu Technology
Table of Contents
CSS-MP-V15
INSTALLATION HW 1.0
Installation Guide
Package content
- Controller x 1, wall hanger x 1, user manual x 1, screwdriver x 1, kit pack x 1 Kit pack : screw x 4, screw anchors x 4, diode (1N4004) x 1 4 pin cable x 1, 8 pin cable x 1, 9 pin cable x 1
Wall-hanger size
Specifications
- Dimension : 122.5 x 185 x 89(mm)
- Power : 9-24 VDC/ 1A
- Wiegand communication : Max to 100 meters
- R5485 communication : Max to 1000 meters
- Face recognition distance : 50 — 100 cm
- Install Wall: recommend installation height 115~125 cm
Installation instructions
Application structure
( Terminal + CSS-A10 RELAY BOX)
(Terminal + CSS-All RELAY BOX)
Support POE power supply, only support single machine, door lock needs
additional power supply
Terminal Front Description
Installation
| Recommended installation height
---|---
Installed height CM (Bottom of the machine)| Identify users
Height CM
115| 153-190
117| 155-195
119| 157-200
121| 159-205
123| 161-210
125| 163-215
The installation height is mainly for a shorter person The face is aligned to the lower edge of the display frame
|
---|---
The installation height is mainly for shorter persons Recognition distance is
about 50-100cm Recommended installation height from the bottom of the machine
to the ground is about 115-125cm| Please bow your head slightly when
recognizing to improve the recognition success rate
Installation environment
When installing outdoors, direct sunlight equipment, oblique sunlight equipment, or direct sunlight equipment through windows are prohibited When installing indoors, make sure that the place must be installed away from windows/doors/lamps more than 2 meters away from equipment.
Terminal Back Explanation
Cable diagram
Cable description
4 PIN
485— | GRAY | For Relay Box BF-50 |
---|---|---|
485+ | BROWN | |
VIN | RED | DC 9-24V (1A) |
GND | BLACK |
8 PIN
ALARM-NC| YELLOW BLACK| 10 Relay
Bell Alarm/
Ring Relay
---|---|---
ALARM-NO| WHITE BLACK
ALARM-COM| GREEN BLACK
WG IN 0| RED WHITE| WG Input Connect
WG Reader
WG IN 1| BLACK WHITE
GND| BLACK| GND
LED| ORANGE| Control WG Reader
LED/ Buzzer Action
BUZZER| PINK BLACK
9 PIN
DOOR-NC | YELLOW | Door Relay |
---|---|---|
DOOR-NO | WHITE | |
DOOR-COM | GREEN | |
EXIT | VIOLET | Exit Button |
SENSOR | BLUE | Door Sensor |
FIRE | PINK | Fire Alarm |
GND | BLACK | GND |
WG OUT 0 | GRAY BLUE | WG Output |
WG OUT 1 | ORANGE BLACK |
FCC Warning
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20cm between the radiator and your body.