Hikvision DS-PK1-E-WB Wireless LED Keypad User Manual
- June 5, 2024
- Hikvision
Table of Contents
Hikvision DS-PK1-E-WB Wireless LED Keypad
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures,
charts, images and all other information hereinafter are for description and
explanation only. The information contained in the Manual is subject to
change, without notice, due to firmware updates or other reasons. Please find
the latest version of this Manual at the Hikvision website
(https://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals
trained in supporting the Product.
and other Hikvision trademarks and logos are the properties of Hikvision in
various jurisdictions. Other trademarks and logos mentioned are the properties
of their respective owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT
DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND
“WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY,
OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR
OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL,
CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS,
DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA,
CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF
CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN
CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF
THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY
RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL
OPERATIONS, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK,
HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER,
HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU
ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE
LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT
DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT
LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA
PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY
PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF
MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL
WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR
UNSAFE NUCLEAR FUEL CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE
LATTER PREVAILS.
-
This product and – if applicable – the supplied accessories too are
marked with “CE” and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU, the RoHS Directive 2011/65/EU. -
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see:
www.recyclethis.info
replacement of a battery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium battery types);- disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion;
- leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas; and
- a battery subjected to the extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas
-
2006/66/EC (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see:www.recyclethis.info
Warning
This is a class A product. In a domestic environment, this product may cause
radio interference in which case the user may be required to take adequate
measures.
FCC Information
Please take attention that changes or modification not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm
between the radiator and your body. FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference.
- This device must accept any interference received, including interference that may cause undesired operation
Warning
- Do not ingest battery, Chemical Burn Hazard
- Keep new and used batteries away from the children.
- If the battery compartment does not close securely, stop using the product and keep it away from children.
- If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
Caution
- Risk of fire or explosion if the battery is replaced by an incorrect type.
- Improper replacement of the battery with an incorrect type may defeat a safeguard (for example, in the case of some lithium battery types).
- Do not dispose of the battery into fire or a hot oven, or mechanically crush or cut the battery, which may result in an explosion.
- Do not leave the battery in an extremely high temperature surrounding environment, which may result in an explosion or the leakage of flammable liquid or gas.
- Do not subject the battery to extremely low air pressure, which may result in an explosion or the leakage of flammable liquid or gas.
- Dispose of used batteries according to the instructions
Appearance
CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
REPLACEMENT OF A BATTERY WITH AN INCORRECT TYPE THAT CAN DEFEAT A SAFEGUARD.
CAUTION
CHEMICAL BURNING DANGER DO NOT SWALLOW THE BATTERY
KEEP NEW AND USED BATTERIES AWAY FROM THE CHILDREN.
IF YOU THINK BATTERIES MIGHT HAVE BEEN SWALLOWED OR PLACED INSIDE ANY PART OF
THE BODY, SEEK IMMEDIATE MEDICAL ATTENTION.
CAUTION
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUC-TIONS AND LOCAL REGULATION.
CAUTION
WHILE REPLACING THE BATTERIES, REPLACE ALL FOUR BATTERIES AT THE SAME TIME,
AND DO NOT MIX OLD AND NEW BATTERIES.
Indication
LED Indication Description
| Wake up with Fault| Solid orange for 10 s .| ****
| Enrollment Flashing red and green: Enrolling
Green flashes 7 times: Enrolled
Continual green (3 s) and off (3 s): Strong
Signal Continual green and red (3 s) and off (3 s): Medium
Strength Continual Red (3 s) and off (3 s): Weak Continual flashing red (3 s) and off (3 s): Lost
Find Me Flashing red: Operating
Turns off when over time (3 min)
__or control panel power off
Power On Enrolled: Solid green for 1 s: Powered on
---|---|---|---|---
No Fault| Off
****| Tampering Alarm Solid red
Event Alarm Flashing red
No Alarm Off
Note: Event Alarm Priority > Tampering Alarm Priority
| Armed Solid blue for 5 s| Back Light
-The back light is on by default, you can set the On/Off schedule on the web client of the control panel. Refer to the user manual of control panel for details.
-It turns off when there is no key operation for more than 10 s.
-If the keypad is not enrolled to the control panel, the back light is off.
Wake up while armed Solid blue for 10 s
Arming Failed Blue turns Off
Disarmed Green flashes 2 times
Disarming Failed Green turns Off
Buzzer Description
Operation completed: Beep twice
Operation failed: Beep three times
Enrollment
- Remove the screw on the bottom of the keypad.
- Disassemble the keypad and remove the rear panel.
- Power on the security control panel.
- Log in the APP and tap the icon “+” . Scan the QR code or input the control panel serial No. to add the control panel.
- Enroll the peripheral locally, with OR code, or with serial No.
Enroll the Peripheral Locally
- In the APP, tap the “Enrollment Mode” button on the control panel page to make the control panel enter the enrollment status.
- Push the power switch of the peripheral to on, and it will be automatically enrolled to the control panel.
Enroll the Peripheral with QR Code or Serial No.
- In the APP, tap the icon “+”and scan the QR code or enter the serial No. on the peripheral.
- Push the power switch of the peripheral to on, and it will be automatically enrolled to the control panel.
Installation
Note: The additional force shall be equal to three times the weight of
the equipment but not less than 50N. The equipment and its associated mounting
means shall remain secure during the installation. After the installation, the
equipment, including any associated mounting plate, shall not be damaged.
Check signal strength and select installation place
Enter the signal checking mode by operating on the control panel.
Continual green (3 s) and off (3 s): Strong
Continual green and red (3 s) and off (3 s): Medium
Continual Red (3 s) and off (3 s): Weak
Continual flashing red (3 s) and off (3 s): Lost
Operation
Keypad Status
Working Status
| The keypad will enter the sleep status while meeting the following conditions:
RF data transmission key operation
keypad tampering alarm polling
Beeping
LED indication
---|---
Sleep Status
| The keypad will enter the sleep status while meeting the following conditions: No RF data transmission
No key operation for more than 10 s No keypad tampering alarm
No polling No beeping
No LED indication
Enrollment Status
| While the keypad is enrolled to a control panel, it enters the enrollment status. Only if the keypad is enrolled, the key
Free Status
| operation and status indication take eThffercetsi.s no area related to the keypad. The key and back light do not works.
Operation Interval
The interval between the operations (successful or failed) should be more than
3 s.
The continuous operation of the key should be in 10 s.
Keypad Lock
The Key pad will be locked after 3 to 5 failure authentication attempts.You
can set the lock time on the web client of the control panel
Arming Process
Pre-delay
Indication:
The fault LED turns solid orange
Fault Checking
Indication:
The fault LED turns flashing orange
Confirm the operation by press the Arm key
Exit Delay
Indication:
Arming LED turns flashing blue, and the buzzer indicates exit delay.
The Key pad will be locked after 3 to 5 failure authentication attempts.You
can set the lock time on the web client of the control panel\
-
Arm Directly
Press the Arm key to arm the device.
Indication:
Armed: arming LED solid blue for 5 s. Buzzer beeps twice. Arming failed: Buzzer beeps three time. -
Disarm
Press the Disarm key to disarm the device.
Indication:
Armed: Buzzer beeps twice.
Arming failed: Buzzer beeps three time. -
No Instant Operation
The count down is finished.
Indication:
Armed: arming LED solid blue for 5 s. Buzzer beeps twice. Arming failed: Buzzer beeps three time.
Formatting
- Power the keypad off.
- Hold the tamper switch and meanwhile power the keypad on. The formatting completes while the red LED flashes 3 times.
CAUTION
IF THE BATTERY COMPARTMENT DOES NOT CLOSE SECURELY, STOP USING THE PRODUCT AND
KEEP IT AWAY FROM CHILDREN.
Command
The keypad command is shown as follows.
Events | Codes | Notes |
---|
Away arm
| Away arming for all areas:
User password + Away
|
Away arming for specified area: User password + # + Area
No.(1,2.3.4.5.6.7.8.9.010.011.012….. )
+ away
| -The keypad does not display area No. greater than 9.
-If the area No. is greater than 9, enter ” 0XX”for the No..”0″indicates tens digits, and “XX”indicates the actual area No.
-If the selected area is not related to the keypad,the back light of “0” will
Stay arm
| Stay arming for all areas:
User password + Stay
|
Stay arming for specified area: User password + # + Area
No.(1,2.3.4.5.6.7.8.9.010.011.012….. )
+ Stay
| -The keypad does not display area No. greater than 9.
-If the area No. is greater than 9, enter ” 0XX”for the No..”0″indicates tens digits, and “XX”indicates the actual area No.
-If the selected area is not related to the keypad, the back light of “0” will flashes three times.
Disarm
| Disarming for all areas:
User password + Disarm
|
Disarming for specified area: User password + # + Area
No.(1,2.3.4.5.6.7.8.9.010.011.012….. )
+ Disarm
| -The keypad does not display area No. greater than 9.
-If the area No. is greater than 9, enter ” 0XX”for the No..”0″indicates tens digits, and “XX”indicates the actual area No.
-If the selected area is not related to the keypad, the back light of “0” will flashes three times.
Clear alarm| User Password+Hold Disarm|
Fire| Hold “1/Fire Alarm” for 3 s| The Buzzer will beep three times for
failure operation.
PA| Hold “2/Panic Alarm” for 3 s| The Buzzer will beep three times for failure
operation.
Medical| Hold “3/Medical” for 3 s| The Buzzer will beep three times for
failure operation.
Duress
|
(Duress Code)+disarm
| You can set the duress code on the web client of the control panel. Refer to the user manual of control panel for details.
Output
| User Password+Output+relay No.(1,2.3.4.5.6.7.8.9.010.011.012…………………………………………………….. )+
#
| -If the relay No. is greater than 9, enter ” 0XX” for the No..”0″indicates tens digits, and “XX”indicates the actual relay No.
– A successful command execution implement an operation “Off” or “On”.
Delete Digit| *| Delete the Digit of user password
Specification
Wireless Keypad
RF
| Speed| 42Kbps
Frequency| 433.10MHz
Method| 2GFSK
Distance| 900m (open area)
Interface
| Tamper switch| 1, front and rear panel tamper-proof
Wireless module| For wireless communication
Power switch| Power on/off
Buzzer| 1
Display
| Indicator| 4: fault (orange), enrollment/signal (red/green),
arming(red/green/blue), and alarm (red)
Backlight| white
Key
| Number key| 10: 0 to 9
Function key| 5: *, #, stay arming, away arming, disarming, and
output
Operation
Environment
| Humidity| 10% to 90%
Temperature| -10 °C to 55 °C (14 °F to 131 °F)
Appearance| Color| White
Dimension(W x H x D)| 140mm x 86mm x 22 mm
Installation| Installation| Screw mounting
Power Supply| Power supply| 1.5 VDC, four AA baterries(included), standby
time more than two years
Weight| Weight without
batteries
| 151 g, and 23 g each battery