Gude Pro 1100 A Immersion Water Pump Instruction Manual

June 5, 2024
Gude

Gude Pro 1100 A Immersion Water Pump Instruction Manual

DELIVERED ITEMS

Box Items Box
Items

Service connection

Service connection

Starting-up the machine

Operation

Operation

Operation

Oil change

Cleaning / Maintenance

Technical Data

Submersible sewage pump Pro 1100 a Pro 2200 a Pro 2201 S
Art. No 75800 75805 75810
Service connection 230V~50Hz 230V~50Hz 230V~50Hz
Motor output P1 1100 W 2200 W 2200 W
Max. head of delivery 9 m 17 m 17 m
Max. immersion 5 m 5 m 5 m
Max. delivered quantity 19 800 l/h 42 000 l/h 42 000 l/h
Max. suction 20 mm 20 mm 20 mm
Max. Water temperature 35°C 35°C 35°C
Hose connection 2“ IG 3“ IG 2,5“ IG
Degree of protection IP68 IP68 IP68
Weight 21,5 kg 31 kg 31 kg

Read and understand the operating instructions before using the appliance. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.
In case of any doubts about connection and operation refer please to our customer center

Specified Conditions of Use

The pump is solely used for drainage and for pumping into and out of containers in the house, garden, farm and agriculture and only for water. Respecting technical data and safety precautions.

Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages.

The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams).
When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.

Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.

Do not use the pump for drinking water!

The pump must not be used to pump waste water.

Safety Instructions

Warning!

  • Electric shock! There is a risk of an injury caused by electric shock!
  • This device is not intended for use by persons (including children) with limited physical, sensory or mental capabilities or without the necessary lack experience or knowledge unless they are supervised by a person who is responsible for their safety or were instructed by that person in how to use the device.
  • Children should be supervised to ensure that they do not play with the device.
  • Always keep children and unauthorised persons out of reach of the appliance.
  • Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA) before putting into operation, a qualified electrician must check whether electric safety measures required are in place. Any national regulations in this regard must be complied with.
  • Electric connection to a socket.
  • It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity.
  • Check the voltage. Technical data given on the type label must correspond with electric network voltage.
  • Only use splash proof extension cables approved for outdoor purposes.
  • Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid!
  • Check the cable and/or socket for damages before the appliance putting into operation.
  • To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself.
  • Protect the feeder cable from excessive temperatures, oil and sharp edges.
  • Unplug the device prior to submersion, upon termination of operation, in the course of defect removal and prior to performing maintenance procedures.
  • If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).
  • The pump must not in any case run without fillings.
  • Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
  • The temperature of the drained liquid must not exceed +35 °C.
  • If the lubricant escapes the fluid could become contaminated.
  • If the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed
  • The user is responsible to third parties if pump (dumping stations, etc.) is used.

Risk of injury around the crusher on the bottom of the pump.
Touch the appliance on the top on the handle only. Do not touch the rotating tool.

Requirements for operating staff

The operating staff must carefully read the Operating Instructions before using the appliance.

Qualification: Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using.

Minimum age: Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education

Training: Using the appliance only requires corresponding training by a professional or the Operating Instructions. No special training is necessary

Emergency procedure

Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used. If  you seek help, state the following pieces of information:

  1. Accident site
  2. Accident type
  3. Number of injured persons
  4. Injury type(s)

Maintenance

Before carrying out any work on the machine, disconnect the plug from the socket.

Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug.

The machine must not be used under any circumstances if the machine or the safety devices are damaged.

Refer all servicing to customer service. Use only original accessories and original spare parts.

To ensure long service life of the pump seal we recommend rinsing the pump with clean water in regular intervals.

At winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with appropriate oil (for example, with vegetable oil).

Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.

Oil products must not come into contact with skin, eyes and clothing.
Make sure the oil products do not enter the soil.

Guarantee

Guarantee claims as per guarantee card attached.

The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period.

The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a result of any unauthorised interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee..

GÜDE cannot be held responsible for damages incurred in consequence of unqualified installation or unskilled handling of the pump.

The device has to be checked on a regular basis to ensure perfect functioning.

Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the belowmentioned cases:

  • Unprofessional repairs executed by unauthorised service centres;
  • Use in conflict with the designed purpose, or failure to observe the use as designed;
  • Pump overload with a continuous run;
  • Damage as a result of icing or any other fault caused by climatic influences;

Identical regulations apply for accessory parts.

To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).

Service

Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions?
We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label. Please enter it here for future reference:

  • Serial No.: __
  • Art. No: __
  • Year of production: __

Symbols

Icon  Read the Operating Instructions
Icon Before carrying out any work on the machine, disconnect the plug from the socket.
Icon Cable pulling / transport prohibited
Icon Staying in the transportation medium prohibited
Icon Warning against dangerous electric voltage
Warning against automatic starting
Do not touch the rotating tool.
2 people are needed for implementation.
Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres. Dispose the waste oil in an environmentfriendly manner!
Protect against humidity
This side up

EC-Declaration of Conformity

GÜDE GmbH & Co. KG
Birkichstrasse 6, 74549 Wolpertshausen
Deutschland

We, hereby declare the conception and construction of the below mentioned appliances correspond – at the type of construction being launched – to appropriate basic safety and hygienic requirements of EC Directives. In case of any change to the appliance not discussed with us the Declaration expires

Plunge pump

  • PRO 1100 A #75800
  • PRO 2200 A #75805
  • PRO 2201 S #75810

Appropriate EU Directives
2006/95 EG, 2004/108 EG

Harmonised standards used

  • EN 55014-1:2006 + A1:2009
  • EN 55014-2:1997 + A1:2001 + A2:2008
  • EN 61000-3-2:2006 + A1:2009 + A2:2009
  • EN 61000-3-3:2008
  • EN 50366:2003 + A1:2006
  • EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 +
  • A2:2006 + A13:2008 + A14:2010
  • EN 60335-2-41:2003 + A1:2004 + A2:2010

Wolpertshausen, 2012-01-13

Helmut Arnold
Managing Director

Technical documentation Joachim Bürkle

Inspection and maintenance plan

Time interval Description Any other details
As needed Cleaning and rinsing out Function check of the floating switch
After 12 months Oil change 5     10 W – 40, max 100 ml

Failures – causes – removal

Failures Causes Removal
Engine does not start No power supply. Blocked pump wheel
Floating switch in shutdown position Check the voltage Visually inspect the

pump wheel for foreign objects Check the water level
Pump does not suck| Water level too low Blocked pump wheel| Switch the pump off, water level must go up
Remove the obstruction
Insufficient amount of water pumped| The crusher wheel is dirty
Water level quickly drops down
Maximum head of delivery exceeded Broken piping| Clean the crusher wheel
Ensure sufficient inflow
Check the transport line
Check the transport line