Hikvision DS-PDBG8-EG2-WE Wireless Glass Break Detector User Manual
- June 5, 2024
- Hikvision
Table of Contents
Hikvision DS-PDBG8-EG2-WE Wireless Glass Break Detector
Warning
- Do not ingest battery, Chemical Burn Hazard
- Keep new and used batteries away from the children.
- If the battery compartment does not close securely, stop using the product and keep it away from children.
- If you think batteries might have been swallowed or placed inside any part of the body, seek immediate medical attention.
Caution
- Risk of fire or explosion if the battery is replaced by an incorrect type.
- Improper replacement of the battery with an incorrect type may defeat a safeguard (for example, in the case of some lithium battery types).
- Do not dispose of the battery in a fire or a hot oven, or mechanically crush or cut the battery, which may result in an explosion.
- Do not leave the battery in an extremely high temperature surrounding environment, which may result in an explosion or the leakage of flammable liquid or gas.
- Do not subject the battery to extremely low air pressure, which may result in an explosion or the leakage of flammable liquid or gas.
- Dispose of used batteries according to the instructions.
Appearance
Battery + –
- + identifies the positive terminal(s) of equipment that is used with, or generates a direct current.
- – identifies the negative terminal(s) of equipment that is used with, or generates a direct current.
Enrollment
- Log in to the APP Store, download, and install the App.
- Power on the security control panel.
- Log in to the APP and tap the icon “ + “. Scan the QR code or input the control panel serial No. to add the control panel.
Enroll the Peripheral Locally
- In the APP, tap the “Enrollment Mode” button on the control panel page to make the control panel enter the enrollment status.
- Loosen the screw and remove the rear panel.
- Power on the peripheral, and it will be automatically enrolled to the control panel.
Enroll the Peripheral with QR and serial No
- In the APP, tap the icon “+” and scan the QR code or serial No. on the peripheral.
- Loosen the screw and remove the rear panel.
- Power on the peripheral, and it will be automatically enrolled to the control panel.
Test
- BG (Break Glass) Test
- Use a tester to simulate the sound of glass break at the required place.
- If the blue LED flashes 2 s, the installation position for BG detection is properly. If the LED indicator is still off, adjust the position of the detector.
Installation
Check Signal Strength
- Enter the signal checking mode by operating on the control panel. Trigger the detector.
- Solid Green for 3 s – Strong Signal
- Solid Orange for 3 s – Medium Signal
- Solid Red for 3 s – Weak Signal
- Red light flashes for 3S – Lost Signal
Install the Detector
- Dig the groove to disassemble the device.
- Method 1: Secure the rear panel to the wall with two screws.
- Method 2: Paste rear panel on the wall with the sponge tape.
Note
- To make the TAMPER work properly, the thickness of the sponge tape should be no more than 1mm.
- Installing with sponge tape is non-EN compliant.
- Close the front and the rear panel.
- You should install the sensor and the magnetic stick at the door or window’s edge. Make sure they are aligned with the door or window’s edge.
- (optional)route the cable through the cable hole if external inputs required.
Functions
- You can add two external inputs (each input can be set as NO\NC\TAMPER\Pulse) via the AX PRO client.
- While Any of the two inputs generates an alarm event, the detector reports the alarm to the AX PRO. The LED keeps blue for 2 s.
Formatting
- 1. Remove the battery.
- Hold the TAMPER button and power the detector on at the same time.
- The red LED flashes 3 times when the formatting is completed.
Set-Up with App
- You can view the device status including temperature, signal intensity, battery level, lid, external input, etc.,on the device page.
- Tap the button to enter the settings page.
Disallowed field adjustable settings: None
Operation Caution and Device Maintenance
- All the electronic operations should be strict in compliance with the electrical safety regulations, fire prevention regulations, and other related regulations in your local region.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipmentM installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
- -Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- If smoke, odors, or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service center.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
- Do not place the device in extremely hot (refer to the specification of the device for the detailed operation temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation.
- The device for indoor use shall be kept from rain and moisture. Exposing the equipment to direct sunlight, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction, however), and affecting the endurance of the sensor at the same time.
- Improper use or replacement of the battery may result in a hazard of explosion. Replace with the same or equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufacturer.
- Do not expose the device to the corrosive gas. Otherwise, equipment damage may occur.
- Do not expose the device to an explosive situation.
Specification
Sensor | Omnidirectional electret microphone |
---|---|
Detection range | 8m radius |
Glass type | Float, Plate, Tempered, Wired, Laminated Leaded, Double glazing |
Glass thickness | 2.4mm to 6.4mm |
Glass size | 0.3m x 0.3m to 3m x 3m |
External Inputs | 2 |
Input options | Normal and Fast Sensitivity with Pulse Count |
Programmable pulse count | Yes |
Normal input sensitivity | 300ms |
Tamper protection | Front & Back |
LED indicator | Blue(alarm) |
Encapsulated plastic | Yes |
Operating temperature | -10 °C to 55 °C (14 °F to 131 °F) |
-10 °C to 40 °C (14 °F to 104 °F) Certified
Storage temperature| -20 °C to 60 °C (-4 °F to 140 °F)
Operating humidity| 10% to 90%
Installation| Wall/Ceiling mount
Dimension (H × W × D)| 107.0 mm x 38.8 mm x 24.5 mm
Weight| 134 g
Wireless technology| Tri-X Wireless Technology
Environment temperature Indicator| Yes
2-way wireless communication| Yes
Transmission frequency| 868MHz
Frequency hopping| Multichannel transmission
Signal strength indicators| Yes
RF range| 1.6Km (free space)
Enrolling methods| Power up, Remote ID, QR code
Battery| CR123A x 2 (included)
Standard battery life| 3 years
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, images, and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of this Manual on the Hikvision website (https://www.hikvision.com/). Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.
HIKVISION and other Hikvision trademarks and logos are the properties of Hikvision in various jurisdictions. Other trademarks and logos mentioned are the properties of their respective owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE, AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS. YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITY FOR ABNORMAL OPERATIONS, PRIVACY LEAKAGE, OR OTHER DAMAGES RESULTING FROM CYBER-ATTACKS, HACKER ATTACKS, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED. YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS.
CE
This product and – if applicable – the supplied accessories too are marked with “CE” and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU, the RoHS Directive 2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info
replacement of a battery with an incorrect type that can defeat a safeguard (for example, in the case of some lithium battery types);
- disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery, that can result in an explosion;
- leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas; and
- a battery subjected to extremely low air pressure that may result in an explosion or the leakage of flammable liquid or gas.
waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>