Welcome

Thank you for purchasing this PTZ camera!

This owner’s manual is designed to be a reference tool for your system.
Please read this manual carefully before operating the unit and retain it for future reference.
Should you require any technical assistance, contact Speco Technologies Tech Support at 1-800-645-5516

Important Safeguards and Warning

  1. Electrical safety
    All installation and operation here should conform to local electrical safety codes.
    Use a certified/listed 24VDC/AC power supply only.
    Please note: Do not connect two power supplying sources to the device at the same time; it may result in device damage! The product must be grounded to reduce the risk of electric shock.
    Improper handling and/or installation could run the risk of fire or electrical shock.

  2. Environment
    Heavy stress, violent vibration or exposure to water is not allowed during transportation, storage and installation.
    This product should be installed in a cool, dry place away from direct sunlight and heat sources.
    Do not install the product in extreme temperature conditions.
    Do not expose the camera to electromagnetic radiation. Otherwise it may result in CMOS sensor failure.
    Do not block any ventilation openings.
    Do not allow water and liquid intrusion into the camera.

  3. Operation and Daily Maintenance
    Please shut down the device and then unplug the power cable before you begin any maintenance work.
    Do not touch the CMOS sensor optic component. You can use a blower to clean the dust on the lens surface. Always use the dry soft cloth to clean the device. If there is too much dust, use a cloth dampened with a small quantity of neutral detergent. Finally use the dry cloth to clean the device.
    Please use a professional optical cleaning method to clean the enclosure. Improper enclosure cleaning (such as using cloth) may result in poor IR functionality and/or IR reflection.
    The grounding holes of the product are recommended to be grounded to further enhance the reliability of the camera.

Warning

This camera should be installed by qualified personnel only.
All the examination and repair work should be done by qualified personnel.
Any unauthorized changes or modifications could void the warranty.

Statement

This guide is for reference only.
Product, manuals and specifications may be modified without prior notice. Speco Technologies reserves the right to modify these without notice and without incurring any obligation.
Speco Technologies is not liable for any loss caused by improper operation.

Note:
Before installation, check the package and make sure that all components are included.
Contact your rep or Speco customer service department immediately if something is broken or missing in the package.

Overview

Product Overview

  1. LAN
  2. 3.5mm Audio Out
  3. 3.5mm MIC In
  4. Alarm I n /Alarm Out
  5. Power

Note: DC24V and AC24V power supply are optional.

Installation

Please make sure the wall is strong enough to bear the dome camera’s weight. Please make sure the camera is powered off during installation.

Install SD Card
  1. Loosen the two screws of the dome.

  2. Open the cover and insert SD card.
    Install SD Card

Install the Speed Dome
  1. Pull the cables through the bracket. Mount the speed dome to the bracket.
    Install Speed Dome

  2. Secure the speed dome to the bracket with the screws.
    Install Speed Dome

  3. Drill the screw holes on the wall according to the drill template. Then insert the plastic plugs into the holes.

  4. Drive the two screws to the holes indicated by the arrows (left) and leave 12mm clearance.

  5. Connect the cables and then hang the bracket on the wall.
    Installation Instruction

  6. Fasten the bracket to the wall with four screws.
    Installation Instruction

Cable Connection

Cable Connection

Alarm Connection:

  1. Alarm Input
  2. a) There is one independent alarm input port (ALM-IN1) and one grounding port (ALM-GND).
  3. b) Alarm input(NO type): Connect DC5V~DC12V voltage between the alarm input port( ALM-IN1) and the grounding port (ALM-GND).
  4. c) Alarm input(NC type): Disconnect the voltage between the alarm input port(ALM-IN1) and the grounding port (ALM GND).
  5. Alarm Output
  6. a) Support 1CH alarm output including OPEN, COM connections.
  7. b) Alarm output: One passive switch for user to connect alarm devices; the alarm output state will be auto on/off according to your setting.

Web Operation and Login

IP Scanner can search for the device on the local network.

Operation
  1. Make sure that the camera and the PC are connected to the same local network. The camera is set to DHCP by default.

  2. Install IP Scanner from the CD and run it after installation.
    Web Operation

  3. In the device list, you can view the IP address, model number, and MAC address of each device. Select the applicable device and double click to open up the web viewer. You can also manually enter the IP address in the address bar of the web browser (Internet Explorer 8 and up).
    Web Operation

The login interface is shown above. Default user name is admin and password is 1234. After logging in, follow directions to install applicable plugins.

Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

speco technologies User Manuals

Related Manuals