FRYMASTER ESG35T High-Efficiency Value Gas Fryer Installation Guide

June 5, 2024
FRYMASTER

FRYMASTER ESG35T High-Efficiency Value Gas Fryer

FRYMASTER-ESG35t-High-
Efficiency-Value-Gas-Fryer-logo

NOTICE
This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster Factory Authorized Servicer (FAS) or other qualified professional should perform installation, maintenance, and repairs. Installation, maintenance, or repairs by unqualified personnel may void the manufacturer’s warranty.

NOTICE
This equipment must be installed in accordance with the appropriate national and local codes of the country and/or region in which the appliance is installed.

NOTICE TO U.S. CUSTOMERS
This equipment is to be installed in compliance with the basic plumbing code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug Administration.

DANGER
Improper installation, adjustment, maintenance or service, and unauthorized alterations or modifications can cause property damage, injury, or death. Read the installation, operating, and service instructions thoroughly before installing or servicing this equipment. Only qualified service personnel may convert this appliance to use a gas other than that for which it was originally configured.

DANGER
Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipped with legs must be stabilized by installing anchor straps. If a flexible gas line is used, an additional restraining cable must be connected at all times when the fryer is in use.

DANGER
The front ledge of the fryer is not a step! Do not stand on the fryer. Serious injury can result from slips or contact with the hot oil.

DANGER
Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance.

DANGER
Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak must be posted in a prominent location. This information can be obtained from the local gas company or gas supplier.

NOTICE
IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS FRYMASTER FOOD SERVICE EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRECTLY FROM FRYMASTER, OR ANY OF ITS AUTHORIZED SERVICERS, AND/OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID. FURTHER, FRYMASTER AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED SERVICER.

NOTICE
The Commonwealth of Massachusetts requires any and all gas products to be installed by a licensed plumber or pipe fitter.

Safety Information

Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual you will
find notations enclosed in double-bordered boxes with the symbol . The information contained in the box concerns actions or conditions that may cause or result in injury to personnel or damage to your system, and/or cause your system to malfunction.

General Installation Instructions

DANGER
Building codes prohibit a fryer with its open frypot of hot oil being installed beside an open flame of any type, including those of broilers and ranges.

DANGER
This appliance must be installed with sufficient ventilation to prevent the occurrence of unacceptable concentrations of substances harmful to the health of personnel in the room where it is installed.

DANGER
No structural material on the fryer should be altered or removed to accommodate placement of the fryer under a hood.

DANGER
Single fryers must be restrained to prevent tipping when installed in order to avoid the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to battery of appliances or installing the fryer in an alcove, or by separate means, such as straps or chains.

DANGER
Do not attach an apron drainboard to a single unit. The appliance may become unstable, tip over, and cause injury. The appliance area must be free and clear of combustible material at all times.

NOTICE
This appliance is only for professional use and shall be used by qualified personnel only.

CLEARANCE AND VENTILATION

This fryer must be installed with a 6-inch (150-mm) clearance at both sides and back when installed adjacent to combustible construction. No clearance is required when installed adjacent to non-combustible construction. A minimum of 24-inches (600-mm) clearance should be provided at the front of the fryer. The fryer flue opening must not be placed close to the intake of an exhaust fan, and the fryer must never have its flue extended in a “chimney” fashion. An extended flue will change the combustion characteristics of the fryer. To provide the airflow necessary for good combustion and burner operation, the areas surrounding the fryer front, sides, and rear must be kept clear and unobstructed. The fryer must be installed in an area with an adequate air supply and adequate ventilation. Adequate distances must be maintained from the flue outlet of the fryer to the lower edge of the ventilation filter bank. Filters should be installed at an angle of 45°. Place a drip tray beneath the lowest edge of the filter. For U.S. installation, NFPA standard No. 96 states, “A minimum distance of 18-inches (450-mm) should be maintained between the flue outlet and the lower edge of the grease filter”. Frymaster recommends that the minimum distance be 24-inches (600-mm) from the flue outlet to the bottom edge of the filter.

INSTALLATION
NOTE: Unless special ordered, this fryer is designed for operation at altitudes of 2000 feet (610 meters) and below. The unit must be modified for operation above 2000 feet (610 meters).
For units equipped with legs: Lift the unit and move it into its final position. Do not drag or push the fryer into position. Doing so may damage the legs. Level the unit front to back and side to side. If the fryer is not level, the unit will not function efficiently. ESG Series gas fryers cannot be curb mounted and must be equipped with either legs or casters provided.

  •  Adjust leg height with an adjustable or 1-1/16-inch (27-mm) open-end wrench by turning the hexagon-shaped foot on the bottom of the leg. NOTE: The foot is for minor leg height adjustment only. Do not adjust outward more than ¾-inch (19-mm).
  •  When leveling the unit, the leg body should be held firmly to keep the leg from bending or rotating while turning the foot to the required height.For units equipped with casters: Roll the unit into its final position and lock the front casters

Pre-Connection Preparation

NATIONAL CODE REQUIREMENTS:
This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug Administration. This equipment is manufactured to use the type of gas specified on the rating plate attached to the door. Connect equipment stamped “NAT” only to natural gas and that stamped “PRO” only to LP (Propane) gas.

Heat Inputs
Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity are listed in the table below:

**MODEL***

| NOMINAL HEAT INPUT-

Qn (BTU)

|

GAS TYPE

|

ORIFICE SIZE (MM)

| MANIFOLD GAS PRESSURE (INCH W.C.)|

ORIFICE QUANTITY

---|---|---|---|---|---

ESG35T

|

70

67

|

NAT LP

|

2.18 (#44)

1.40(#54)

|

3.8

10

|

3

3

Connection to the Gas Supply Line
NOTE: The gas supply (service) line must be the same size or greater than the fryer inlet line. This appliance is equipped with a ½-inch (15-mm) inlet. The gas supply line must be sized to accommodate all gas-fired equipment connected to the line. Consult the local gas company or supplier, or your local contractor for minimum supply line requirements.
NOTE: If quick-disconnect supply lines or flex lines are used, increase supply line size to ¾-inch (22-mm) or larger.

DANGER
A manual shut-off valve must be installed in the gas supply (service) line upstream of this appliance and in a position where it can be reached quickly in the event of an emergency.

DANGER
The fryer must be connected to the gas supply specified on the rating and serial number plate located on the inside of the appliance door. DO NOT ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!

DANGER
Before connecting new pipe to this appliance, the pipe must be blown out thoroughly to remove all foreign material. Foreign material in the burner and gas valve will cause improper and potentially dangerous operation.

DANGER
All connections must be sealed with a joint compound suitable for the gas being used and all connections must be tested for leaks using a solution of soapy water before lighting any pilots. Never use matches, candles, or any other ignition source to check for leaks. If gas odors are detected, shut off the gas supply to the appliance at the main shut-off valve and immediately contact the local gas company or an authorized service agency for service.Adequate means must be provided to limit the movement of fryers without depending upon the gas line connections. If a flexible gas hose is used, a restraining cable must be connected at all times when the fryer is in use. NOTE: The installation must be inspected after it is complete to ensure it meets the intent of these instructions. The on-site supervisor and/or operator(s) should be informed that the appliance is installed with restraints. If restraints are removed to move fryer (cleaning beneath and behind, relocation, etc.), ensure that they are re-installed when fryer is returned to its permanently installed position

DANGER
This appliance was configured at the factory for a specific type of gas. Converting from one gas type to another requires the installation of specific gas-conversion components. Switching to a different type of gas without installing the proper conversion components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT

CONFIGURED!
Conversion of this appliance from one type of gas to another should only be performed by qualified, licensed, and authorized installation or service personnel, as defined in Section 1.5 of this manual. See gas valve illustration below and gas valve, burner and orifice location on page 1-5 when performing the following conversions. When converting from natural gas to propane (or vice-versa), the following procedures apply:

  • Burner orifices and pilot orifice MUST be replaced (see page 1-5 for kit part numbers).
  • Adjust orifice gas pressure by turning the gas-valve adjustment screw (see page 1-2 for gas types and pressures).
  • After adjustment, replace the adjustment-screw cover.
  • Affix the new label included with the conversion kit next the existing rating plate stating that the gas type has been caonverted. Remove any references to the previously used gas from the existing rating plate.
  • Conversion from one gas family to another (i.e. changing from natural gas to propane) requires special components. Obtain the necessary components using the table on page 1-6.
    Conversions can only be executed by qualified, factory-authorized personnel.

INSTALLATION INSTRUCTIONS

Gas Conversion Components
Use the following components to convert from natural gas to propane and vice- versa. See Section 1.5 for orifice quantities required for conversion.

  •  Natural to Propane: 826-3174
  •  Propane to Natural: 826-3175

Initial Startup
Wash the unit and accessories thoroughly with hot, soapy water to remove any film residue, dust or debris. Rinse and wipe dry. Close the drain valve completely. Ensure the operating thermostat and high-limit thermostat sensing bulbs inside the frypot are securely seated in the holding clamp.

Operating the Gas Valve
Rotate the knob counter-clockwise to the ON or PILOT positions. Depress and rotate the knob clockwise to turn the valve OFF.

Pilot Lighting Procedures
NOTE: This fryer was tested, adjusted and calibrated to sea level conditions before leaving the factory. Adjustments may be necessary to meet local conditions, and are to be performed only by qualified service personnel. Adjustments are the responsibilities of the customer or dealer and are not covered by Frymaster warranty. The pilot is located high in the cabinet center, at the base of the frypot. Use a long match to light the pilot. Perform the following steps in sequence before lighting the pilot:

  1.  Turn off the manual shut-off valve on the incoming gas supply line.

  2.  Turn the operating thermostat to the OFF position.

  3.  Depress and turn the gas valve knob to the OFF position.

  4.  Wait at least 5 minutes for any accumulated gas to disperse.

  5.  Fill the frypot with oil, shortening or water to the bottom OIL LEVEL line scribed on the frypot back. Ensure heating tubes are covered in liquid prior to engaging burners.
    NOTE: If solid shortening is used, pack the shortening into the frypot, ensuring the shortening is packed beneath, between and above the tubes prior to operating fryer.

  6.  Open the manual shut-off valve on the incoming gas supply line and rotate the gas valve knob to the PILOT position.

  7.  Push and hold the knob in and apply a lighted match to the pilot burner head. Continue to hold the knob in for about 60 seconds after the flame appears on the pilot. Release the knob. The pilot should remain lit.

Lighting the Burners

  1. Ensure the frypot is filled with oil or shortening to the lower of the two oil level lines embossed on the back wall of the frypot. NOTE: If solid shortening is used, pack the shortening into the frypot, ensuring the shortening is packed beneath, between and above the tubes prior to operating fryer.
  2.  With the pilot lit, push down and slowly turn the gas valve knob to the ON position.
  3.  Rotate the operating thermostat knob to the desired frying temperature. The burner should light and burn with a strong blue flame.

Shutting the Fryer Down
For temporary shutdown, turn the operating thermostat to the OFF position and cover the frypot. Ensure oil is kept in the frypot if the pilot is lit. For complete shutdown, turn the operating thermostat to the OFF position, turn the gas valve knob to the OFF position and cover the frypot.

Daily Operation

  1.  Do not allow grease to accumulate or harden on the frame, body, or flue of the fryer. Clean the fryer inside and out with a solution of detergent and hot water daily.
  2.  Filter the cooking oil by draining the frypot through a filter cone at least daily. After the oil has been drained from the frypot, remove any residue from the pot, using a non-abrasive scraper if necessary.
  3.  Clean the frypot at least once each week by filling it to just below the upper oil level mark with water. Add one cup of detergent and bring the solution to a boil. Allow the solution to simmer for 10-15 minutes, then drain and rinse the frypot with clean water twice. Add ¼ cup of white vinegar to the last rinse to neutralize alkalinity remaining from the detergent. Wipe the frypot surfaces with a dry towel before refilling with cooking oil. If the fryer is not to be used immediately after cleaning, wipe the frypot interior with a light coat of cooking oil to prevent rust.

Recommended Spare Parts

DESCRIPTION PART # ESG35T
Operating Thermostat 826-2013
High-Limit Thermostat 807-3516
Thermopile 807-3485
Pilot Burner, Natural Gas 810-2032
Pilot Burner, Propane Gas 810-2155
Orifice, Natural 810-4389
Orifice, Propane 810-3529
Gas Valve, Natural 807-1603
Gas Valve, Propane 807-1604
Leg 810-3168
Caster, 5-inch w/o Brake 810-0356
Caster, 5-inch w/Brake 810-0357

Wiring Diagram

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>