Frymaster 826-2554 Millivolt In-line Switch Installation Kit
Millivolt In-line Switch Installation Instructions
- Follow the instructions below to add an inline switch to a millivolt fryer.
- This kit puts an inline switch in series with the thermostat and the gas valve. See the wiring diagram (Figure 6) for Honeywell or (Figure 7) for Robertshaw on Pages 2 & 3 of these instructions for more information.
| In This Kit (826-2554)|
---|---|---
Part No.| Description| Qty
220-4789| Mount, Millivolt Switch| 1
802-2276| Label, ON/OFF| 1
809-0449| Screw, #10-½ Phillips Truss Head| 2
106-4386| Mini Toggle Switch Assembly| 1
807-0015| Inline Connector| 1
- On the gas valve, remove the white wire coming from the thermostat (Figure 1). NOTE: Gas valves differ in appearance. See the wiring diagram on pages 2 & 3.
- On the same terminal, attach the red wire coming from the provided inline switch (Figure 2). NOTE: Gas valves differ in appearance. See the wiring diagram on pages 2 & 3
- Plug the white wire removed from the valve into the inline connector opposite the red wire (Figure 3).
- Mount the ON/OFF switch on the side of the fryer frame, just inside the door (Figure 4).
- Tuck the wiring behind the mounted switch to prevent tangling and accidental wire breaks (Figure 5).
HONEYWELL WIRING DIAGRAM
ROBERTSHAW WIRING DIAGRAM
Documents / Resources
|
Frymaster 826-2554 Millivolt In-line Switch Installation
Kit
[pdf] User Manual
826-2554, 220-4789, 802-2276, 106-4386, 807-0015, 826-2554 Millivolt In-line
Switch Installation Kit, 826-2554, Millivolt In-line Switch Installation Kit
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>