Borotto Real 24 Automatic Egg Incubator Instruction Manual
- June 5, 2024
- Borotto
Table of Contents
- Borotto Real 24 Automatic Egg Incubator
- REAL series incubators
- Warnings for safe use
- Identification plate
- Declaration of conformity
- Presentation of the manual
- HOW TO USE
- Technical features and specifications
- General information
- Transport and handling instructions
- Selection and preservation of the eggs for incubation
- CHOICE OF THE EGGS
- Preparing of the incubator
- Periodic egg inspection during incubation (candling)
- Chick hatching
- First days of life
- Problems that may be encountered during incubation
- Diagnosis regarding widespread chick death during hatching
- Cleaning and sanitizing
- Problems that may occur during use
- REAL INCUBATOR GUIDE
- Disposal
- Warranty / after sale service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Borotto Real 24 Automatic Egg Incubator
REAL series incubators
Warnings for safe use
When using electrical appliances, it is always required to adhere to some basic safety precautions.
- READ THE INSTRUCTIONS IN THEIR ENTIRETY.
- Use the appliance only with electrical systems indicated on the label or in the manual.
- Do not touch hot surfaces (there is a resistor in the appliance). Wait at least 10 minutes after switching off in the event you need to access hot parts for cleaning or maintenance.
- Do not place the appliance near heat sources.
- Keep away from the reach of children.
- Do not leave the appliance unattended for lengthy periods when connected to power.
- To prevent electrocution, do not immerse the appliance in water or other liquids.
- Detach the plug from the power socket when the appliance is not in use and/or prior to opening (lifting the cover plate) and cleaning.
- Do not use the appliance with damaged cables or plugs, or if it has been dropped or damaged in some way. Consign the appliance to the nearest authorized service center requesting check, or repair.
- Use of accessories not recommended or not sold by the manufacturer is forbidden.
- Do not use the appliance outdoors and do not move the appliance when in operation.
- The appliance can be used by children older than 8 years of age and persons with reduced physical or mental capacity, or without experience or the necessary knowledge, as long as supervised by an adult or after they have received instructions related to safe appliance use and understand the dangers related to it. Cleaning and maintenance operations by user must not be carried out by unsupervised children.
- Check the condition of external cables then plug the appliance in the power socket before use. To disconnect the unit unplug it from the socket.
- During use, place the appliance on a horizontal, stable and well aerated surface, at a height of 20″ above the floor.
- Children must be supervised to ensure they do not play with the appliance.
- Do not cover internal and external parts to prevent seriously damaging operation of the product.
- The power supply cable must be positioned and protected in such a way that it can neither be accessed nor damaged by pets.
- The power supply cable must be placed so that the plug can be easily accessible to disconnect the device from the mains.
- To unplug the appliance, hold the plug directly and extract it from the wall outlet.
- Any modifications to this product, not expressly authorized by the manufacturer, may involve deterioration of the safety and forfeiture of the warranty on its use by the user.
- STORE THESE INSTRUCTIONS WITH CARE.
Warning symbols used on the product and in this manual
Symbol | Description |
---|---|
**** | **** Obligation not to cover the appliance during operation |
**** | **** Presence of live parts with consequent electrical hazard |
Presence of hot surfaces, fire hazard | |
**** | Obligation to read the operating instructions before using the product |
Identification plate
The equipment is fitted with an identification plate showing the equipment’s identification details and the main technical specifications.
PLATE FACSIMILE
Declaration of conformity
EU Declaration of conformity
The undersigned Andrea Borotto, as legal representative of the company BOROTTO® headquartered in Via Papa Giovanni Paolo II, 7 37060 Buttapietra (VR) Italy VAT No 03787910235
DECLARES
That the product as per label shown below:
Is intended for the use: incubator for animal eggs, specifically: hen,
pheasant, turkey, guinea fowl, quail, grey partridge, partridge, goose,
Muscovy/common/wild duck, peacock, rock partridge, pigeon, Virginia quail,
exotic birds and birds of prey.
The following declaration of conformity is released under the exclusive
responsibility of the manufacturer. And it conforms to the following
directives:
- Directive 2014/35/EU known as Low Voltage Directive.
- Directive 2014/30/EU known as “Electromagnetic compatibility Directive”.
- Directive 2011/65/EC ROHS II
The products are made in compliance with the following standards:
- Standard CEI EN 60335-1:2012 + A11:2014 + A1:2018 + A2:2018 Safety of electrical appliances for household use and similar – Safety – Part 1: General Regulations.
- Standard CEI EN 60335-2-71:2003 + A1:2007 Safety of electrical appliances for household use and similar – Part 2: Special regulations for electrical heating appliances for animal husbandry.
- Standard EN 55014-1:2017
- Standard EN 55014-2:2015
- Standard EN 61000-3-2:2014
- Standard EN 61000-3-3:2013
- Standard EN 61000-6-3:2007 + A1:2011
- Standard EN 61000-6-1:2007
The person responsible for the technical dossier and
Presentation of the manual
This manual contains instructions regarding installation, maintenance and use
of all models of REAL series egg incubators.
The manual’s sections are divided into chapters and paragraphs. The index
lists all the topics within the manual. This manual is intended for users of
the equipment, and concerns its technical life after its production and sale.
In the event it should be subsequently be transferred to third parties for any
reason (sale, loan for use, or any other reason), the incubator must be
delivered complete with all the documentation.
Electronic format copy of this instructions manual can be downloaded at
www.premier1supplies.com.
Copyright: This manual contains proprietary information and may not be,
even partially, provided to third parties for any purpose and in any form,
without the prior written consent of the manufacturer BOROTTO®.
The manufacturer declares that the information contained herein is consistent
with the technical and safety specifications of the egg incubator the manual
refers to.
NOTE: This instructions manual is an original BOROTTO® product.
NOTE: The REAL 49 PLUS version is made with a special engineering polymer
in high HEAT-RESISTANT ABS, which makes the machine solid and sturdy. The
material is also provided with a special BIOMASTER® silver-based ion
antimicrobial additive to destroy bacterial flora that may develop inside the
incubator.
Two “DUST STOP” antimicrobial closing caps are also fitted to close the water
filling nozzles.
ATTENTION:
These instructions help acquiring familiarity with the incubator. Carefully
reading these instructions results in high hatching yield, therefore this
manual must not only be followed to the letter but seriously complied with!
Neglecting or overlooking even one instruction only will make a difference in
hatching! Egg selection is therefore
recommended: the secret of high hatching yield lies exactly in obtaining
compliant eggs.
Danger: Should the fan not work, immediately unplug the appliance and contact the service.
NOTE: demonstrative photos equivalent for all models of the REAL series
HOW TO USE
KEY
1 | Control panel |
---|---|
2 | Incubator cover plate |
3 | Incubator base |
4 | Tray filling nozzles |
5 | Electrical cable |
6 | Automatic egg turning unit |
(accessory: may be supplied already installed according to the required model)
7| DUST STOP antimicrobial closing caps (only supplied with REAL 49 PLUS)
8| Element joint rod
9| Egg tray element
10| Bottom grate to be only used at hatching (last 3 days)
11| Temperature control buttons
12| Digital display
13| Resistor on LED
14| The steel tab of the egg turning device must be inserted properly into the
slot of the eggs support
Technical features and specifications
Incubator model | REAL series |
---|---|
Type of eggs to be incubated | hen, pheasant, turkey, guinea fowl, quail, grey |
partridge, partridge, goose, Muscovy/common/wild duck, peacock, rock partridge, pigeon, Virginia quail,
exotic birds and birds of prey.
Rated Voltage and Frequency| Single phase, 110/120 Volt 50/60 Hz
Maximum power| 100W Real 24| 150W Real 49
Average consumption| 50Wh Real 24| 70Wh Real 49
Noise| A-weighted noise pressure level emitted from the device below 70dB(A)
Display| Digital temperature control with decimal point
Ventilation| Turbine
Thermostat| Microcomputer with PID management. With tolerance of +/-0.1°F
Range| Temperature modifiable from Min. 86°F to Max. 104°F
Humidity in the incubator| 45-55% with water in one tray
60-65% with water in both trays
Dimensions and weight
of Real 24
| 20″ x 14″ x 10″ – Weight: 8.5 lbs
Dimensions and weight
of Real 49 Plus
| 23″ x 22″ x 10″ – Weight: 12 lbs
Capacity of Real 49| 49 eggs placed in the cell device or 196 small-sized eggs
(such as quail eggs)
Capacity of Real 24| 24 eggs placed in the cell device or 96 small-sized eggs
(such as quail eggs)
General information
The REAL series incubator has been designed for hatching chicks of hen,
pheasant, guinea fowl, quail, grey partridge, grouse, ducks (Muscovy/
common/wild duck, goose, etc.), peacock, turkey, rock partridge, pigeon,
Virginia quail, exotic birds and birds of prey.
Semi-automatic version incubator: it is fitted with a semi automatic system to
tilt eggs, operated from the outside via a lever connected to the cell device
located in the base of the incubator.
Automatic version incubator (with automatic egg turning motor): it is equipped
with an automatic system to tilt the eggs actuated from the outside via a
motor that performs a complete cycle in 1 hour.
The heat required for incubation is generated by an electrical resistor
controlled by a latest-generation digital PID microcomputer control that makes
it possible to regulate in a constant and precise manner the average internal
temperature, setting it with the buttons on the control panel.
Ventilation takes place by means of a turbine fan that evenly distributes the
warm, humid air.
The natural surface humidification comes from the water contained in the trays
stamped on the bottom of the incubator. Trays are filled via two external
nozzles, eliminating the need to open the incubator.
Transport and handling instructions
TRANSPORTING THE INCUBATOR
The device can be easily transported and does not pose any special risks
regarding its handling.
REAL incubators packaged individually can be manually transported by one
person.
PACKAGE
The Real incubator package ensures safe transport of the device and all its
components.
Depending on the delivery method of the end customer, the package comprises a
single card board box with supporting bubble wrap around the components. These
also serve to protect the unit during long-term storage.
Beware of humidity Handle with care
TRANSPORT
ATTENTION: the entire package must be kept for any machine transport.
OPENING THE PACKAGE
To remove the machine:
- Open the box carefully without damaging it
- Remove all protective devices from the incubator
- Check that the package contents include:
- Incubator base
- 2 “DUST STOP” antimicrobial caps to close the water filling nozzles. (ONLY SUPPLIED WITH REAL 49 PLUS)
- Base hatching grid
- Egg tray
- Complete incubator cover
- Automatic egg turning unit (if purchased)
- User manual and purchase receipt
HANDLING THE INCUBATOR
Take the incubator from the package and place it directly on a horizontal
surface higher than 20″. Since its weight varies from 5.4 lbs – 15 lbs
(depending on the model), this operation can be carried out by one person.
ATTENTION: the incubator must be lifted from the base only. Do not lift the
incubator by applying force on the clamps, lever, or similar.
Selection and preservation of the eggs for incubation
It is recommended to incubate eggs from one’s own farm or neighboring
breeders. Shipped eggs will normally have less than 50% hatching, due to
factors of travel stress, vibration, temperature changes, embryos that have
died from asphyxiation, because eggs that are closed inside packaging do not
breathe!
If you use shipped eggs, rest them on an egg platform for at least 24 hours
with the tip downwards before incubating them.
Choose eggs from parents that are well developed, well fed and healthy.
MANDATORY: The parents must not be inbred (no brothers must be crossbred;
the males must always come from another farm), as they would result in eggs
containing weak embryos destined to die in the process of hatching (the chick
grows, but remains trapped inside the egg as it is weak and does not have the
strength to break the shell to hatch), nature is very selective and does not
allow vulnerable creatures to be born!
The breeders must be sexually mature, and the males must be present in the
right proportions with respect to females, adhere to the information given in
the following table:
PROPORTION BETWEEN | AGE AT SEXUAL MATURITY | |
---|---|---|
Species | Male | and |
Hen | 1 | |
Pheasant | 1 | |
Duck | 1 | |
Goose | 1 | |
Guinea fowl | 1 | |
Partridge | 1 | |
Quail | 1 | |
Turkey | 1 |
CHOICE OF THE EGGS
The embryo begins developing before incubation and, therefore, it needs
proper care, otherwise there will be a decrease in the hatching percentage.
Below are some rules that will be helpful in obtaining suitable eggs for
incubation:
-
Collect the eggs at least 5 times a day to prevent environmental contamination. Never incubate eggs that have been at a temperature lower than 41°F or higher than 75.2°F. Over this figure the germinating cell starts developing abnormally, it still develops when incubated but the chick will die during hatching!NEVER store the eggs in the refrigerator.
-
Do not incubate eggs dirty with fecal material, as during incubation the temperature and humidity would lead to the establishment of a bacterial flora that would contaminate all the eggs, infecting the embryos and resulting in chick death during hatching. The eggs must not have blood stains.
Do not wash the eggs for any reason, at the most you may dry brush them with an abrasive sponge. -
Store eggs in a cool room with a temperature between 57°F and 61°F and humidity 65-75%.
-
Store the eggs in the egg trays with the tip downwards.
-
The eggs are suited to incubation from the second to the sixth/seventh day after laying. Incubating eggs older than 8 days significantly reduces the hatching percentage, up to almost zero in the event of eggs stored longer than 15 days!
-
Choose eggs of normal shape (they must not be elongated, spherical, undulated or with any other malformation).
-
The egg shell must not be cracked, broken, creased, soft, thin or with bluish spots (old eggs).
-
Allow cold eggs (from storage temperature) to slowly reach room temperature before placing them in the incubator. Suddenly going from 53°F to 100°F would cause condensate on the shell which would lead to a reduction in hatchings.
-
During incubation DO NOT add eggs at a later time!
BOROTTO RECOMMENDS: If eggs are bought from amateurs, make sure the breeding farms are registered and comply with animal health regulations in force, which means they have the breeding code issued by their relative local health authorities and are accredited to it for serological tests made with regular frequency. This is the only way to have eggs from breeders that undergo a specific vaccination program defined by a competent veterinarian and in accordance with the local checklist on farming and the size of shelters. Availability of first-class genetic material, which is obtained after strict selection and breed adaptation, enables better size and productivity of animals as well as reduces the risk of incubating eggs with high bacterial contamination or diseases and thus resulting in poor hatching results (due to premature death of the embryo in the egg before birth).
Preparing of the incubator
During transportation, pay attention not to cause collisions and/or damage to
the incubator. Always position flat, avoiding crushing and/or breakage.
For successful hatching, it is recommended to keep the incubator in
residential premises, not in sheds, porches or garages. The room temperature
should ideally be between 68°F and 77°F and have no air drafts. The suitable
room must be well aerated and comfortable. Ensure the incubator is not exposed
to direct sun rays or placed close to direct heat sources such as radiators,
stoves, fireplaces, boilers etc. Relative humidity must be between 50% and
75%.
ATTENTION: DO NOT USE THE INCUBATOR IN ROOMS WITH TEMPERATURES BELOW 68°F OR HIGHER THAN 77°F!
Do not use or store the incubator in rooms where are chemicals, poisons, toxic or flammable substances, even at low concentrations, as they adversely affect embryo development. Do not use the incubator where there is a danger of water or other substances being sprayed.
Use
MANDATORY: SANITIZE THE INCUBATOR BEFORE STARTING THE INCUBATION PROCESS: refer to Chapter 15
Place the incubator on a flat table higher than 20″ above the floor.
Do not place other objects between the product and the surface, for example
tablecloths or covers.
Remove the cover plate and lay it next to the incubator.
Remove the bottom plastic hatching grate, which is not used at the moment (it
is only used in hatching, i.e. for the last 3 days). NEVER LEAVE IT IN THE
INCUBATOR
DURING THE INCUBATION PERIOD!
Ensure the egg supports are well positioned in their seats and that (in the
automatic version) the steel tab of the egg turning motor is properly inserted
in the slot of the egg support, i.e. the plastic of the egg support must be
inserted onto the steel tab (14-Fig. 6).
Fill one of the nozzles at the outer base of the incubator (either one) with
drinking water, pouring slowly (4-Fig. 1).
REAL 49 PLUS VERSION ONLY: Use the 2 “DUST STOP” antimicrobial caps to close
the 2 water filling nozzles (7-Fig.2). NOTE: THESE 2 CAPS MUST NEVER BE
REMOVED DURING INCUBATION. THEY MUST ONLY BE REMOVED FOR THE TIME REQUIRED TO
FILL WATER AND MUST BE CLOSED AGAIN!
Replace the cover plate, ensuring the rim of the incubator’s upper part
perfectly meshes with the duct in the cover plate base.
Plug the cover plate plug in a power socket. Ventilation will start
immediately, the internal temperature will then be displayed and the yellow
LED will switch on (13-Fig. 5). The LED will remain on for about 20-40
minutes, until the set temperature is reached, then it will begin flashing.
Set the temperature at 99.7°F (ideal temperature for all bird species).
To set the temperature, use the (+) and (-) buttons on the upper control panel
(1-Fig. 1). Press one of the two buttons to access the program (the letter “P”
will appear next to the degrees). Keep pressing until the desired temperature
is obtained. Once the temperature has been set, wait for it to be stored. Wait
a few seconds for the current internal temperature and the letter “C” to be
displayed.
NOTE: leave the incubator on while empty for 2-3 hours before inserting
eggs in order to stabilize the temperature and humidity (the incubator must
operate without eggs).
After ensuring the incubator works properly, remove the cover plate and lay it
next to the incubator. Gently place the eggs in the cells with the tip
downwards. Close the incubator again.
For the semi automatic incubator:
At least 4 times a day change the tilt of the eggs placed in the cell device by means of the lever located at the front of the incubator. Tilt the lever alternatively to the right or left, stopping it in the position corresponding to 10 o’clock or 2 o’clock. Never leave the lever (and consequently the eggs) in vertical position (12 o’clock). Move the lever gently to prevent any shocks to the eggs.
For the automatic incubator (with egg turning motor):
Plug the egg turning motor plug in a power socket. The egg turning motor will
then start turning.
NOTE: the egg turning motor moves the eggs constantly by tilting them
from right to left and vice-versa. This movement is NOT visible since the
motor turns very slowly like the hands of a clock, and completes a cycle from
right to left (or vice-versa) in 1 hour. The egg turning motor can thus
deceive you into thinking it is not turning. But in fact, it is working
correctly and there is no need to worry that is has stopped.
The incubation cycle now starts. It is advisable to mark the day on a calendar
and follow the instructions of the table below.
Check the water level daily, and top off with clean drinking water using the filling nozzles. The water level, which may be seen in the filling nozzle, coincides with the internal level in the tray. Humidity is generated by the water surface not its quantity, therefore the moisture content in the incubator will always be the same, whether the water level in the tray is minimum, half or full!
ATTENTION: do not cover the incubator with blankets for any reason or enclose within a box thinking this will lead to energy savings! The incubator is designed to exchange the air inside it through the two windows (slightly detached from the cover plate to let air through): if the embryo does not breathe, it will die by asphyxia!
SUGGESTION: change the position of the eggs every 5 days, moving those in the center of the incubator with those on the sides (this is to ensure better even hatching).
BOROTTO RECOMMENDS: to permanently control the level of humidity and automatic input of water in the machine, you can use the automatic SIRIO humidifier, which is manufactured and distributed by BOROTTO® and available from the incubator sales outlets or from the website: www.premier1supplies.com
Information regarding correct incubation: all poultry eggs
Suggested temperature at the start of incubation: 99.7°F
Suggested temperature during the last 3 days before hatching: 99.2°F
Refer to the following table to obtain successful incubation:
Species
|
Incubation time
| For correct humidity at the start of
incubation
| Do not turn the eggs after| For correct humidity during the last 3
days before hatching
---|---|---|---|---
Hen| 21 days| Fill 1 water tray| Day 18|
Fill the second tray with water.
Pour 2 or 3 glasses of water at the bottom of
the incubator.
Pheasant| 25 days| Fill 1 water tray| Day 22
Quail| 17 days| Fill 1 water tray| Day 14
Guinea fowl| 26-28 days| Fill 1 water tray| Day 23
Turkey| 28 days| Fill 1 water tray| Day 25
Grey partridge – Partridge – Rock partridge| 25 days| Fill 1 water tray| Day
22
Peacock| 28 days| Fill 1 water tray| Day 25
Quail| 23-23 days| Fill 1 water tray| Day 20
Goose| 30 days| Fill 1 water tray| Day 27
Swan goose| 34 days| Fill 1 water tray| Day 31
Domestic duck| 28 days| Fill 1 water tray| Day 25
Muscovy duck| 35 days| Fill 1 water tray| Day 32
SUMMARY
INCUBATION: During incubation maintain temperature at 99.7°F and fill only one water tray. HATCHING: In the last 3 days before expected hatching, the eggs must not be turned any longer. They must be laid on the hatching grid and humidity must be increased by filling the second tray as well pouring 2 or 3 glasses of water at the bottom of the incubator. Then set the temperature to 99.2°F.
The incubation days table is approximate, it is recommended to leave the incubator on 2 or 3 days longer over the deadline, to allow laggards to hatch.
Incubation of palmiped eggs (goose, duck, etc.)
From the tenth day of incubation to the last three days before hatching, open the incubator once a day and let the eggs cool down for 15/20 minutes. Before repositioning the cover plate spray a thin layer of water ( ATTENTION: NEVER MOISTEN THE EGGS WHEN THEY ARE STILL WARM, WAIT FOR THEM TO COOL DOWN). The appliance must be unplugged during this operation.
Information regarding correct incubation: eggs of all exotic birds
Temperature to maintain during incubation: 98.6°F
Temperature to maintain in the last 3 days before hatching: 97.7°F
Refer to the following table by keeping in mind that incubation varies
according to the species. For detailed information regarding special species,
consult the relative texts.
PARROTS| Incubation time| Incubation humidity| HATCHING
(last 3 days)
---|---|---|---
Amazon species| 24-29 days| Fill 1 water tray|
Fill the second tray with water.
Pour 2 or 3 glasses of water at the bottom of the incubator.
Do not turn the eggs in the last three days before hatching.
Ara| 26-28 days| Fill 1 water tray
Macaw| 26-28 days| Fill 1 water tray
Lovebirds| 22-24 days| Fill 1 water tray
African grey parrots| 28 days| Fill 1 water tray
Eclectus parrots| 28 days| Fill 1 water tray
SUMMARY
INCUBATION: During incubation, maintain temperature at 98.6°F and fill only one water tray.
HATCHING: In the last 3 days before expected hatching, the eggs must not be turned any longer. They must be laid on the hatching grid and humidity must be increased by filling the second tray as well pouring 2 or 3 glasses of water at the bottom of the incubator. Then set the temperature to 97.7°F.
The incubation days table is indicative, it is recommended to leave the
incubator on for 2 or 3 days more than the indicated
deadline to allow laggards to hatch.
Periodic egg inspection during incubation (candling)
Candling is a complicated and delicate operation that may result in errors such as eliminating viable eggs. Since it is optional, we advise not to perform it if one has no experience and to proceed with incubation. Otherwise, the incubated eggs may be periodically inspected by candling. This operation must be performed in a dark room using the egg candler, which is available on the website www.premier1supplies.com, following the table below:
Species | 1st inspection | 2nd inspection | 3rd inspection |
---|---|---|---|
Hen | at 8 days | at 11 days | at 18 days |
Pheasant | at 8 days | at 12 days | at 20 days |
Guinea fowl | at 8 days | at 13 days | at 23 days |
Turkey | at 8 days | at 13 days | at 25 days |
Grey Partridge / partridge | at 8 days | at 12 days | at 20 days |
Peacock | at 9 days | at 14 days | at 25 days |
Goose | at 9 days | at 15 days | at 27 days |
Mallard and wild duck | at 9 days | at 13 days | at 24 days |
Muscovy duck | at 10 days | at 15 days | at 30 days |
Extract the eggs from the incubator one by one and check them immediately. The egg may remain outside the incubator for 2 minutes at most. With a little experience, and using the suitable instrument, the eggs may be inspected without extracting them from the incubator. In that case, open the incubator and place the candler onto each egg. The light beam lets you see the embryo. Never turn or shake the eggs with violence as this would cause the blood vessels to break and result in embryo death.
1st Inspection: start of the incubation: It is usually difficult to see the embryo because it is encased in the yolk: blood vessels are visible near the air cell and on the tip. If the egg has not been fertilized the inside will be uniform, without any blood vessels and the yolk will be in the middle. In that case scrap the egg. It is likely that in this stage the inside of eggs with a thick or brown shell cannot be seen well: these will be checked in the second inspection.
2nd Inspection: development of the embryo: The mesh of blood vessels is normally visible in the tip of the egg and the embryo will appear as a dark spot. If the blood vessels are not visible this means that the embryo is dead.
3rd Inspection: embryo check: The embryo normally occupies the entire egg, therefore the blood vessels should no longer be visible. The air cell is large, If the embryo does not occupy the entire space, blood vessels are visible, the air cell is small and the white has not been used up, this means that the embryo is underdeveloped and the egg must be scrapped.
Chick hatching
The operation described below is critical and must be done quickly, it is recommended to be assisted by another person to speed up the operation so the eggs do not get excessively cold.
For the semi automatic incubator:
A. In the last 3 days before the expected hatching, extract the metal lever
located at the front of the incubator.
B. Follow the table below from letter B onwards.
For the automatic incubator (with egg turning motor):
A. In the last 3 days before the expected hatching stop the egg turning motor
by unplugging it from the power socket, possibly when the eggs are still in
vertical position.
B. Remove the eggs from the cells and gently place them on a blanket.
C. Remove the egg cells.
D. Pour 2 or 3 glasses of water at the bottom of the incubator.
E. Place the plastic grate in the base of the incubator paying attention to
ensure the two tabs of the grate cover the 2 communicating water ducts to
prevent the chicks from falling in and drowning.
F. Distribute the eggs on top and close the cover plate again.
G. Fill the second tray with water.
H. If poultry eggs have been incubated, set the temperature at 99.7°F. Or
97.7°F if exotic eggs have been incubated.
VERY IMPORTANT: During hatching (in the last 3 days) NEVER open the
incubator!
Opening the incubator continuously out of curiosity in the last 3 days to see
the chicks hatch will result in the chick inside the egg dying!
Lifting the cover uselessly disperses the accumulated CO2 and humidity and
would thus require more time to bring it back to the required values. At most,
open the machine once daily to remove the chicks already hatched, and once
they are completely dry, close it immediately. The newly hatched chicks must
be kept inside the incubator for approximately 12 hours. They can stay inside
up to 3 days without drinking or eating and not suffering.
First days of life
Place the chicks in an environment that assures the necessary heat and light,
with no air drafts, where they can be fed and watered.
For heating, hang a Prima Heat Lamp® about 12″ over the chicks. Adjust the
temperature by changing the height of the lamp. A heat plate may also be used.
Both available at
www.premier1supplies.com.
Benefits of the infra-red lamp
Infra-red lamps not only serve to warm the chick, but act in depth, on the tissues and muscles, fixing calcium in the bones and supporting the expansion of the blood and lymph vessels, thus improving blood circulation and, consequently, the nutrition of cells. This promotes healthy growth of the chick which will also be more resistant to disease.
Nutrition
Chicks usually start eating and drinking from the second/third day of life.
Place in the box/pen: a drinker and a feeder with chick feed. We suggest
scattering some feed also on the newspaper. Feeders and drinkers are available
at website www.premier1supplies.com.
If other drinkers are used, ensure the pan is not higher than 1″ -1.5″,
otherwise the chicks will risk getting wet or drowning. To prevent that, place
pebbles on the bottom, which will also attract the chick to the drinking
water.
Problems that may be encountered during incubation
PROBLEM | POSSIBLE CAUSE | SUGGESTION |
---|---|---|
Clear eggs. There are no blood vessels (through candling) | Non-fecundated eggs | |
due to too many or too few males, old or infertile | Only use young, zestful |
and unrelated males and not exceeding 3 years of age
Blood rings visible in candling
| Egg storage was too long before incubation| Do not store the eggs longer
than 7 days
The temperature in the egg storage
room was too high or low
| Ensure the temperature in the egg storage
room is between 41°F and 76°F
Inadequate egg care before incubation| Check proper egg storage
Low egg collection frequency| Collect the eggs more often throughout the day
Many dead embryos or chicks that die before pipping
| Breeders are inbred| The breeders must not be related
(the male MUST NOT be the female’s
brother)
Old eggs| Store the eggs for 7 days at most
Aged parents| The parents must not be older than 3 years
Nutritional deficiencies| Feed parents with adequate feed (use
parents feed)
Eggs have travelled long distances| Incubate local eggs
Incorrect humidity during incubation| Comply with the information provided on
filling the water trays
The incubator has been opened several times during hatching| Open once a day
at most to remove properly dry chicks
The incubator has been operating in excessively hot or cold premises| Ensure
the room temperature is between 66°F and 77°F
Bacterial contamination from a dirty incubator| Remove scale and disinfect
the incubator before use, refer to Chapter 15
Ensure the eggs are properly clean
Eggs with high bacterial
contamination
| READ CHAPTER 8, section regarding
“BOROTTO RECOMMENDS”
Other causes| ADHERE TO CHAPTERS 8 and
9 – 9.2 – 9.3 – 9.4 – 11 – 14 -14.1
The eggs explode| The eggs are dirty| Incubate clean eggs
Chicks with lower limb malformations
| Incorrect humidity during incubation| Adhere to the information provided
regarding humidity management in table 9.3.
Inbred breeders| The parents must not be related
Diagnosis regarding widespread chick death during hatching
Obtaining poor hatching results is always frustrating, especially once the
embryo develops but the chick does not manage to survive and dies, in most
cases, in the last 3 days prior to hatching (late embryo mortality).
This type of embryo death can be caused for various reasons: in fact, nature
is very selective and systematically tends to prevent birth of weak subjects!
First and foremost, it is necessary to emphasize that even before implementing
the operation method of the incubator described in this manual, the secret to
obtain good hatching lies in starting with suitable eggs, in full compliance
of the instructions in this manual.
If the eggs were properly selected, but the results did not meet expectations,
we recommend prudence in considering the incubator inappropriate or making a
complaint without having previously eliminated the possibility that the
embryos or chicks died for other reasons.
The last and final analysis, which is the only chance to be certain about the
cause of death before birth, can be obtained through a report from a
laboratory specialized in microbiological analysis, better still a veterinary
epidemiology center, which can also carry out proper autopsy analysis. The
causes of failed hatching can be thus ascertained, which, in most cases, are
due to: inbreeding, parents malnutrition, embryonic hypotrophy, altered
ovogenesis, viral infections or bacterial contamination, more frequently due
to: escherichia coli, pseudomonas, mycoplasmosis, staphylococcus, etc.
Fertility photoperiod
The month in which you incubate is also important. The average hatching
obtained out of season is usually very low, especially considering the
decrease in duration of the photoperiod.
Even when candling provides positive fertility results, this does NOT mean
that all embryo eggs will hatch. In fact, if certain embryos are not perfect,
they will develop just the same in the first stages but will die inside the
egg in the late phase of development, and will not hatch.
Below is a table regarding average embryo fertility based on the monthly
length of the photoperiod:
Cleaning and sanitizing
WARNING: In terms of temperature and humidity, the conditions created inside the machine to guarantee the best results during the incubation and hatching phases are also ideal to develop harmful bacteria, such as: Salmonella, Campylobacter, Staphylococcus, Legionella, Escherichia coli, etc.
The resulting bacterial cross-contamination of embryos and early mortality of the chicks are among the main causes of poor hatching results.
Below is the correct procedure to follow to clean and sanitize the incubator
perfectly in order to prevent harmful proliferation of bacteria and to
decrease the death rate of chicks in the hatching stage.
Cleaning, sanitizing and maintenance operations must be performed with
appliance off, unplugged and after a sufficient time to allow hot parts to
cool down.
The heating element must be kept clean from dust and any dirt.
Cleaning incubator bottom: at the end of the cycle thoroughly wash the bottom of the incubator with a water softener to remove any scaling left during water evaporation (do not use steel wool or scrapers to remove the scale), rinse thoroughly with water to remove all water softener residues before moving to the sanitizing stage in order to avoid chemical reactions.
Sanitizing incubator bottom: disinfect with bleach or other similar
disinfectant products (the ones used for laundry are fine), then pour about
half a glass at the bottom of the incubator with a little water, shake the
incubator so that the liquid covers every part of the base including the
walls, then rinse as well as possible.
MANDATORY: TO SANITIZE THE INCUBATOR BASE ONLY USE BLEACH OR DISINFENTAT
BASED ON WATER! IT IS FORBIDDEN TO USE ALCOHOL OR OTHER CHEMICALS.
If you disinfect the inside of the incubator with alcohol or other chemical
detergents, when the incubator is used again the residual chemical particles
will affect the embryos leading death during hatching.
Do not remove the automatic egg turner from the incubator.
Incubator cover plate cleaning: accurately clean the outside of the cover
plate with a soft cloth moistened with alcohol.
Blow the inside of the cover plate with compressed air to remove the down lost
by chicks during hatching.
NOTE: SANITIZING MUST BE PERFORMED BEFORE INCUBATING
STORAGE: perfectly dry the inside of the incubator, operating it dry for
2-3 hours.
Store the incubator in a dry and clean place, away from shocks and changes in
temperature.
Do not place any objects on top of the incubator.
No electrical maintenance is to be performed by the user.
Problems that may occur during use
PROBLEM | POSSIBLE CAUSE | SUGGESTION |
---|---|---|
The product or its accessory does not switch on | Disconnected cable | Connect |
the cable
Damaged cable| Request technical support for the repair
Other| Request technical support
Required temperature is not reached
| Unsuitable room temperature| Move to another room
Thermostat does not work| Request technical support
Resistor does not heat| Request technical support
Damaged product parts that cause heat dispersal| Request technical support
An accessory does not work
| Disconnected cable| Connect the cable
Damaged cable or component| Request technical support for the repair
Other| Request technical support
REAL INCUBATOR GUIDE
Temperature and humidity inside the incubator
- Reading temperature and humidity parameters inside an incubator with common thermometers or probe hygrometers does not provide reliable data regarding the actual environmental parameters inside the egg and thus imposed on the embryo.
- In fact, the patented air treatment system inside REAL incubators is designed specifically on a studied ventilation variability, which creates precise variations in the temperature and humidity parameters that are suitable and ensure the best hatching results. However, it is highly unlikely that the parameter recorded at a single point corresponds to what is shown on the display. But this is not a defect!
- In fact, a turbulence effect is specifically generated inside REAL, which is modified by the constant, slow variation of the egg’s inclination. This is where the differences are found in the temperatures recorded from one point to another.
- This physiological variation in the temperature was studied in order to get as close as possible to the conditions of the egg during natural brooding. In fact, to stimulate the embryo in its first critical 8 days of brooding, the part of the egg that touches the hen’s chest is approximately 104°F, whereas, the temperature of the part of the shell in contact with the underlying hay is approximately 95°F.
- Our sophisticated laboratory equipment and calibration during assembly of our incubators (ACCREDIA certification), ensure perfect temperature on the surface and inside the egg, and NOT that of ventilated air!
- A very reliable test on the correct temperature to which incubated eggs have been subjected and which can easily be verified by any user is represented by measuring the total time elapsed between putting the eggs into a started machine and the moment of hatching.
- The direct correlation between the adequate temperature during the incubation phase and the time taken by the embryo to be born (chick) is scientifically proven.
- A hatching duration between 20 and 21 days indicates perfect compliance with the environmental parameters inside the machine.
- On the other hand, if the eggs hatch by day 18: the temperature was too high during incubation; if they hatch after 22 days, it was too low.
- This is obviously the case if the machine was used as designed, with room temperature between 20 and 25 degrees centigrade.
Disposal
In implementation of Directives 2011/65/EU and 2012/19/EU, LEGISLATIVE DECREE
4 March 2014, n. 27 and LEGISLATIVE DECREE 14 March 2014 , n. 49, relative to
the use of hazardous substances in electrical and electronic equipment and the
disposal of waste, the symbol of the crossed wheelie bin, shown here,
indicates that at the end of its service life the product must be collected
separately from other waste.
The user shall therefore deliver the appliance at the end of its service life
to the suitable electric and electronic separate waste collection facilities.
Appropriate separate collection for subsequent recycling of the decommissioned
appliance, treatment and environmentally compatible disposal contributes to
avoiding possible negative effects on the environment and health and promotes
the recycling of the materials the appliance consists of.
Unlawful disposal by the user involves the application of the administrative
sanctions provided for by the laws in force.
The information related to the correct procedure of available collection
systems must be obtained from the Local Waste Disposal Service.
AEE ITALY REGISTRATION NUMBER: IT14080000008557
Warranty / after sale service
BOROTTO® (hereinafter the Manufacturer) grants a 24 month warranty to the
product from the date of purchase. During this period, the Manufacturer
undertakes to repair at its expense any defect that might occur during normal
operation of the appliance, attributable to manufacture.
Upon requesting servicing under warranty, show this contract complete with
date, stamp and signature.
The incubator must be shipped in its original packaging under the customer’s
responsibility.
If the incubator is in the warranty period and has been used correctly it will
be repaired free of charge. It is understood that no reimbursement shall be
acknowledged in the event of lack of fault or defect of the product. However,
the Manufacturer reserves the right to charge to the customer the expenses
incurred for the demand for servicing in warranty in the absence of the
prerequisites.
The warranty does not cover damage caused by:
- transport;
- wear, water, dirt;
- use in conditions other than herein specified by the Manufacturer;
- repairs or modifications made by personnel not authorised by the Manufacturer;
- force majeure (earthquakes, floods, fires, etc.).
Only use the incubator for the purpose it is intended for; uses other than
indicated in these instructions shall be deemed as hazardous and the
Manufacturer disclaims any and all liability for any damage to persons,
animals or property arising from failure to comply with this warning.
The Manufacturer shall not be deemed liable, nor shall they grant any
servicing under warranty or compensation for negative results due to failure
to comply with these instructions, misuse, incorrect installation of the
appliance or problems arising from the inadequacy of the electrical
installations or other facilities, or arising from environmental, climate or
other conditions, or from entrusting the appliance to minors or persons
manifestly unsuitable to using or handling the appliance.
No compensation shall be requested from the Manufacturer for indirect damage
due to loss of material occurred as a consequence of product defects such as,
eggs inserted or to be inserted in the incubator, or further damage to
property, persons or animals.
Please contact us for warranty service:
Premier 1 Supplies
2031 300th St, Washington, Iowa 52353
800-282-6631
premier1supplies.com
References
- Electric Fence, Ear Tags, Sheep & Goat Equipment, Clippers and Shears, Netting, Backyard Poultry Supplies and more! - Premier1Supplies
- Incubatrici Borotto - Marchio leader nella progettazione di incubatrici
- Electric Fence, Ear Tags, Sheep & Goat Equipment, Clippers and Shears, Netting, Backyard Poultry Supplies and more! - Premier1Supplies
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>