hoymiles HT10 Transmitter Installation Guide

June 4, 2024
hoymiles

hoymiles HT10 Transmitter Installation Guide
hoymiles HT10 Transmitter

Appearance

Appearance

Appearance

  1. Transmitter
  2. Din Rail PSU
  3. Core 1
  4. Core 2

System Solution

Single Core

Single Core

Dual Core

Dual Core

Installation

  • Mount Transmitter and power supply on DIN rail.

  • Connect DC leads from power supply to Transmitter.

  • Connect Core to Transmitter. If there is only one core need to connect, please connect Core 1 first.

  • Transmitter

  • Din Rail PSU

  • Core 1

  • Core 2

Note:

  • 85-264VAC or 180-550VAC PSU can be used.
  • 180-550VAC PSU isolation class I requires grounding.
  • 85-264VAC PSU isolation class II does not require grounding

Installation

  • Pass either positive homerun or negative homerun through Cores.
  • Connect wires to AC side of power supply

Note:

  • Install HRSD before powering on Transmitter.
  • Transmitter power supply must be on same AC branch circuit as inverter to meet rapid shutdown requirements.
  • When PV system is operating, the Power LED1 should be lit and the Signal LED2 should be blinking.
  • Place rapid shutdown system label no more than 1m (3ft) from Transmitter or AC disconnect if not at same location.

Note:

  • Max. number of strings per Core*: 5 (75A core) or 15 (150A core)
  • Max. current per Core: 75A or 150A
  • Max. cable length from inverter (+) to inverter (-): 1000ft (300m)
  • With Φ 6 mm DC cable diameter (without DC connector)