steinel RS PRO LED S30 Sensor Switched LED Indoor Light
About this document
Please read carefully and keep in a safe place.
- Under copyright. Reproduction either in whole or in part only with our consent.
- Subject to change in the interest of technical progress.
Symbols
- Hazard warning!
- Reference to other information in the document.
General safety precautions
Disconnect the power supply before attempting any work on the unit.
- During installation, the electric power cable being connected must not be live. Therefore, switch off the power first and use a voltage tester to make sure the wiring is off-circuit.
- Installing the sensor-switched light involves work on the mains supply voltage. This work must therefore be carried out professionally in accordance with national wiring regulations and electrical operating conditions. (e.g.: DE: VDE 0100, AT: ÖVE / ÖNORM E8001-1, CH: SEV 1000)
- Only use genuine replacement parts.
- Repairs may only be made by specialist work-shops.
RS PRO LED S30 / S30 Q
Proper use
- Sensor-switched indoor light with active motion detector for installing indoors
The sensor-switched light is an active motion detector. The integrated HF sensor emits high- frequency electromagnetic waves (5.8 GHz) and receives their echo. The change in echo caused by the slightest movement within the detection zone of the light is detected by the sensor.
A microprocessor then issues the switch command “switch light ON”. Detection is possible through doors, panes of glass and thin walls.
Note:
The high-frequency power of the HF sensor is approximately 1 mW – 1000 times
less than the transmission power of a mobile phone or micro-wave oven.
S 30 package contents (Fig. 3.1)
- Sensor-switched light
- 3 spacers
- 2 slot-in shrouds
- 1 quick-start guide
- 1 safety data sheet
S 30 Q package contents (Fig. 3.2)
- Sensor-switched light with electronics cassette
- 3 spacers
- 2 slot-in shrouds
- 1 quick-start guide
- 1 safety data sheet
S 30 product dimensions (Fig. 3.3)
S 30 Q product dimensions (Fig. 3.4)
S 30 product components (Fig. 3.5)
A Shade
B Electronics enclosure
C Sensor
D Connecting terminal
S 30 Q product components (Fig. 3.6)
A Light enclosure
B Wall mount with electronics cassette
C Sensor
D Connecting terminal
S 30 detection zones for ceiling mounting
1-8 m (Fig. 3.7)
S 30 Q detection zones for ceiling mounting 1-8 m (Fig. 3.8)
S 30/ S 30 Q detection zones for wall mounting 2.5 m (Fig. 3.9)
S 30 luminous intensity distribution (Fig. 3.10) S 30 Q luminous intensity
distribution (Fig. 3.11)
Electrical connection
- Switch OFF power supply (Fig. 4.1)
Connecting the mains power supply lead (Fig. 4.1) The mains power supply lead is a 3-core cable:
-
N= phase conductor (usually black, brown
or grey) -
N= neutral conductor (usually blue)
-
PE= protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors using a voltage tester; then
disconnect from the power supply again. Connect the phase conductor
(L) and neutral conductor (N) to the terminal block.
! Hazard from incorrectly laying
electric cables!
-
The S 30’s cables with basic insulation must not come into contact with the metal enclosure, the LED circuit boards or their connecting wires.
-
Use sealing plugs.
-
Insulation of the incoming NYM cable (right-hand input) must be pushed into the light by
at least 10 mm. -
With through-wiring (S 30): Insulation of the incoming NYM cable (optional, left-hand input) must be pushed in by at least 50 mm.
-
Fix live wires in place by means of comb-type holder.
For DC operation, connect to terminal L “+” and to terminal N “-“.
Important:
incorrectly wired connections will produce a short circuit later on in the
product or your fuse box.
In this case, you must identify the individual conductors once again and
reconnect them. A mains power switch for turning the unit ON and OFF may of
course be installed in the mains supply lead.
Note:
The light source in this light cannot be replaced. If the light source needs
to be replaced (e.g. at the end of its service life), the complete light must
be replaced.
Installation
- Check all components for damage.
- Do not use the product if it is damaged.
- Select an appropriate mounting location, taking the reach and motion detection into consideration.
Mounting procedure for S 30
- Remove shade. (Fig. 5.1)
- Switch OFF power supply. (Fig. 4.1/5.1)
- Mark drill holes. (Fig. 5.2)
- Drill holes and fit ground plugs. (Fig. 5.3)
- Installation with concealed power supply lead. (Fig. 5.4)
- Installation with surface-mounted power supply lead. (Fig. 5.5)
- Connect conductors. (Fig. 5.6)
- Observe warning notes.
- Fix wires in place by means of comb-type holder.
- Fit shade. (Fig. 5.7)
- Switch ON power supply. (Fig. 5.7)
Mounting procedure for S 30 Q
- Switch OFF power supply. (Fig. 4.1/5.8)
- Remove electronics cassette. (Fig. 5.8)
- Mark drill holes. (Fig. 5.9)
- Drill holes and fit ground plugs. (Fig. 5.10)
- Installation with concealed power supply lead. (Fig. 5.11)
- Installation with surface-mounted power supply lead. (Fig. 5.12)
- Connect conductors. (Fig. 5.13)
- Fit light enclosure onto ceiling mount. (Fig. 5.14)
- Switch ON power supply. (Fig. 5.14)
Function
Factory settings (state on leaving the factory)
- Reach setting: max.
- Main light time setting: 10 seconds
- Basic light time setting: 1 minutes
- Twilight setting: 2,000 lux
- Basic light dimming level: 50%
The sensor function is activated in the factory setting so that the light is directly ready for operation. To put the product into reference mode, go to the technical documentation at: www.steinel.de.
Steinel Connect app
To configure the light, you must download the Steinel Connect app from your app
store. You will need a Bluetooth-capable smartphone or tablet.
-
Android
-
iOS
DC operation
Light output is set to 100% when operating on DC power.
Start-up/power interruption
The light’s settings and current operating status are saved automatically in
the event of power failure or disconnection from the power supply. Settings
are reactivated as soon as the mains power supply is restored.
Reach setting
The reach setting can be infinitely varied between 1 and 8 m. Reach can be
reduced in four directions to suit any need by fitting the slot-in shrouds
included. (Fig. 6.1)
Time setting
The main light’s ON time can be set to any period from 5 seconds to 60
minutes. Any movement detected before this time elapses will restart the
timer.
Twilight setting
The chosen response threshold can be infinitely varied from 2 to 2,000 lux.
Basic light level
The brightness of the basic light level setting can be varied between 7% and
100%.
Basic light can be set in relation to time or ambient light level.
Main light level
The brightness of the main light level setting can be varied between 7% and
100%.
Grouping
The RS PRO LED S30 / RS PRO LED S30Q can be operated as a separate light or
several lights can be interconnected in groups via wireless communication.
All lights belonging to a group operate in line with the group parameters set
in the Steinel Connect app. Reach can be set to suit any situation for all
lights in the lighting group.
Fade Time
Fade Time can be used to set the rate of dimming on switching the light ON and
OFF (1 s – 3 s).
Neighboring-light function
The neighboring-light function can be activated and deactivated via the
Steinel Connect app. This function assigns the neighboring groups to the
active lighting group. The active group responds to activation signals from
the neighboring group assigned to it and switches to main light or basic light
as defined in the settings.
Maintenance and care
This product requires no maintenance.
The detector lens may be cleaned with a damp cloth if it gets dirty (do not
use cleaning agents).
Important note:
the control gear cannot be replaced.
Disposal
Electrical and electronic equipment, accessories and packaging must be
recycled in an environmentally compatible manner. Do not dispose of electrical
and electronic equipment as domestic waste.
For EU countries only:
under the current European Directive on Waste Electrical and Electronic
Equipment and its trans-position in national law, electrical and electronic
equipment no longer suitable for use must be collected separately and recycled
in an environ-mentally compatible manner.
Declaration of Conformity
Hereby, STEINEL Vertrieb GmbH declares that the radio equipment type RS PRO
LED S30 /
RS PRO LED S30 Q is in compliance with Directive 2014/53/EU. The full text of
the EU declaration
of conformity is available at the following internet address: www.steinel.de
Manufacturer’s warranty
As purchaser, you are entitled to your statutory rights against the vendor. If
these rights exist in your country, they are neither curtailed nor restrict-ed
by our Warranty Declaration. We guarantee that your STEINEL Professional
sensor product will remain in perfect condition and proper working order for a
period of 5 years. We guarantee that this product is free from material-,
manufacturing- and design flaws. In addition, we guarantee that all electronic
components and cables function in the proper manner and that all materials
used and their surfaces are without defects.
Making Claims
If you wish to make a claim, please send your product complete and carriage
paid with the original receipt of purchase, which must show the date of
purchase and product designation, either to your retailer or contact us at
STEINEL (UK) Limited, 25 Manasty Road, Axis Park, Orton Southgate,
Peterborough, PE2 6UP, for a returns number. For this reason, we recommend
that you keep your receipt of purchase in a safe place until the warranty
period expires. STEINEL shall assume no liability for the costs or risks
involved in returning a product.
For information on making claims under the terms of the warranty, please go to
www.steinel-professional.de/garantie
If you have a warranty claim or would like to ask any question regarding your
product, you are welcome to call us at any time on our Service Hotline 01733
366700.
Technical specifications
Troubleshooting
Troubleshooting| |
---|---|---
GB|
Malfunction| Cause| Remedy|
|
Sensor-switched light without power| ■ Fuse has tripped, not switched ON,
break in wiring
■ Short circuit in mains power supply lead
■ Any mains switch OFF
| ■ Activate, change fuse, turn ON power switch, check wiring with voltage tester
■ Check connections
■ Switch ON mains switch
|
Sensor-switched light will not switch ON| ■ Incorrect twilight setting
selected
■ Mains switch OFF
■ Fuse has tripped
| ■ Readjust
■ Switch ON
■ Activate, change fuse, check connection if necessary
|
Sensor-switched light will not switch OFF| ■ Continued movement within the
detection zone| ■ Check detection zone|
Sensor-switched light switches ON without any identifiable movement| ■ Light
not mounted for detecting movement reliably
■ Movement occurred, but not iden- tified by the observer (movement behind wall, movement of a small object in immediate lamp vicinity etc.)
| ■ Securely mount enclosure
■ Check detection zone
|
Sensor-switched light does not switch ON despite movement| ■ Rapid movements
are suppressed to Minimise malfunctioning or detec- tion zone set too small| ■
Check detection zone|
|
References
- Steinel Group | STEINEL
- Daljinsko Upravljanje d.o.o.
- F.Fonseca - High-tech Solutions since 1978
- Avalehele
- Sensorer | Sensorstyrd belysning från Steinel l KHS
- SAOS Teknoloji STEINEL Türkiye Distribütörü | SAOS Teknoloji
- Herstellergarantie für Unternehmer | STEINEL
- Steinel купить на steinel-russland.ru
- 【steinel 】施特朗中国官方网站
- Steinel Group | STEINEL
- International | STEINEL
- STEINEL | Steinel Group
- Luminaires & Détecteurs | STEINEL