termatech TT22 More stove more heat User Manual
- June 5, 2024
- TermaTech
Table of Contents
- INSTALLATION INSTRUCTION
- INSTALLATION INSTRUCTIONS IN SMOKE CONTROL AREAS
- LIGHTING INSTRUCTION
- MAINTENANCE always use original parts
- 5 YEAR WARRANTY* / RIGHT TO INVOKE LACK OF CONFORMITY
- HINTS
- MALFUNCTIONS
- TECHNICAL SPECIFICATIONS
- SUPPLEMENTARY INSTRUCKTIONS UK
- Installation instructions TT22HST Mounting the soapstone panels UK
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TT22 + TT22R + TT22H + TT22S + TT22HS
TT22HST + TT22RP + TT22RPS
User and mounting manual
Please read also:
SUPPLEMENTARY INSTALLATION INSTRUCTIONS FOR
THE UK MARKET (last 6 pages)
CE approved according to: EN13240 NS3058+NS3059
Congratulations on your new wood-burning stove.
We thank you for choosing a TermaTech wood-burning stove and wish you many
cosy and warm moments in the future.
Before using the stove you should read the user and mounting manual and also
the SUPPLEMENTARY INSTALLATION INSTRUCTIONS FOR THE UK MARKET (last 6 pages of
this manual) so you are familiar with the legal requirements as well as the
instructions regarding maintenance. By this, it is ensured that the product
works as it is intended and you get the most out of your investment for many
years to come.
INSTALLATION INSTRUCTION
(Installation mounting the soapstone TT22HST – page 58)
The stove is intended for intermittent combustion. It is not meant to “heat
over” at night. By following the instruction below in “Lighting instructions”
the best and most environmentally friendly combustion is achieved.
The wood-burning stove is delivered ready for mounting (the exhaust branch may
need to be screwed on) and must be connected to the chimney with a smoke pipe.
The connection between stove and chimney must, as far as possible, be mounted
in one straight piece (with as few bends as possible) and as minimum
horizontally, but preferably rising from the stove to the chimney. Joints must
be tight. Remember that it has to be possible to clean the pipe (possibly with
a cleaning hatch on the pipe).
Any unauthorised changes to the wood-burning stove will be viewed as a
structural change and thereby the warranty will be void and is also a risk to
safety.
In the door on your TT stove there is a spring that makes the door close by
itself when you let go of the handle. This closing device is not a demand in
the UK, Denmark and many other countries and can therefore be removed. In the
bottom hinge the split with lentil head is removed which removes the tension
from the spring. This is most easily done by using a small screw driver and
side-cutting pliers.
National and European norms
The regulations in force at the time in question, including those that refer
to national and European standards, must be respected when installing the
wood-burning stove. Contact your local dealer for further advice and guidance
in connection with mounting. Notify your Hetas installer before you use your
wood-burning stove. It must be ensured that there is sufficient airflow for
the combustion in the stove, so care must be taken concerning closely shut
windows and doors that may hinder the flow of air to the combustion.
Safety references
The surface of the stove as well as knobs, handle, window, smoke pipe, etc.
become very hot when the stove is in use. Touching these parts without
necessary protection (glove or other protective material) can lead to burns.
Remember to make children aware of this danger and make sure to keep them away
from the wood-burning stove when it is in use. For this purpose TermaTech
offers various grates for the protection of children. (Ask your dealer)
Allowed in the wood-burning stove
Only use dry and clean wood for combustion in the wood-burning stove. Maximum
size of logs used in the stove is up to 50 cm in length and 10 cm in diameter.
Maximum filling:
Wood must not be added to the wood-burning stove above the tertiary holes of
the rearmost vermiculite/insulation plates, corresponding to approximately 15
cm from the bottom plate of the combustion chamber.
Only use dry wood. The burning of waste, synthetic materials and other treated
or impregnated materials is not allowed as it is very hazardous to the
environment. Furthermore the stove and the chimney will be damaged by these
materials. There is a danger of emission of unhealthy substances which can
also lead to complaints from neighbours.
Dry and clean wood has a maximum of 20% water which is achieved with outdoor
storage for between 1 year (soft wood) and 2 years (hard wood). The wood must
be in contact with air during storage so the moisture can get out of the wood.
Firewood is not meant to burn overnight. Never close off the airflow completely, instead let the fire die out and light it again when you need it. We warn against closing off the airflow completely. The wood-burning stove can only burn sensibly and environmentally friendly if there is sufficient airflow for the combustion.
Cleaning and checks
The wood-burning stove and the smoke pipe should be checked and cleaned once a
year. The chimney must also be cleaned by the chimney sweep that will set the
necessary intervals for cleaning / sweeping. The wood-burning stove should be
checked by a professional about once a year.
Combustion air
Combustion air is a precondition for a good and clean combustion. The air is
normally taken from the room where the wood-burning stove is mounted, however
in some circumstances it may be necessary to provide extra air in the room
where the stove is placed. This can e.g. be done by mounting an air valve in
the room’s outer wall. Air valves that supply necessary combustion air must be
kept free from blockage. An exhaust fan in the same room or close to the wood-
burning stove can also have a negative effect on the combustion (at worst it
can lead to exhaust gases in the room, even with the stove door closed).
Therefore, in the above case, the wood-burning stove and the exhaust fan must
never be in use at the same time. The amount of air that must be used for
combustion is approximately 8.2m3/per kg. of firewood.
The TT22 models are available with combustion air branch, which has a
connecting pipe/spigot of Ø96mm, use an air hose of Ø100mm. Ask your dealer
for further information.
Adjustable feet
The enclosed adjustable feet are to be mounted from below and used
- if the floor is uneven
- if you want to create the impression that the stove is “flying”/”floating” (0 8 mm)
- if you have bought a molded TT22 glass floorplate
**Distances to flammable materials using UNINSULATED fluepipes**
The stove must be put on a non inflammable foundation. This foundation must as
a minimum cover 150 mm on each side of the stove and 300 mm in front of the
stove. For inflammable material like inflammable walls made of wood,
furniture, etc. the following minimum distances apply for safety reasons
(These distances only apply to the stove. Other distances apply to
fluepipes):
150 mm behind the stove to flammable material.
450 mm beside the stove to flammable material.
150 mm behind/beside if mounted 45° in a corner.
1200 mm in front of the stove to flammable material.
Distance to non-flammable materials
It is recommended that there is a minimum of 50-100 mm behind and beside the
stove so the stove can dispose of the heat, this distance makes cleaning of
and around the stove easier. In addition, refer to the relevant Building
Regulations.
Requirements for the chimney
The chimney must be of sufficient height so the draught conditions are okay
the smoke does not bother anyone. Good draught in the chimney is crucial to
the stove working as intended and burns as environmentally friendly as
possible. The height of the chimney must typically be a minimum of 3.5 m from
the top of the stove to the top of the chimney. The chimney must have a
minimum internal diameter of Ø150mm. The chimney must be equipped with an
easily accessible cleaning hatch. All joints and connections must be tight and
the chimney must be able to provide a draught of at least 1.2 mm water gauge
(12Pa).
It is possible to connect the wood-burning stove to chimneys that are also
used for other purposes. However, the concrete conditions must be assessed by
the fitter and/or chimney sweep.
If the stove is to be mounted with back/rear exit the following is done:
The round, welded or screwed cover plate at the back of the stove is removed.
Then the cut-out piece on the base-plate is removed (the thin division plate).
Be careful not to drop the piece between the back plate and the stove! This is
best done with a screwdriver / chisel or pliers. Finally the screwed smoke
cover is removed and then the exhaust branch can be mounted. Remember to fix
the smoke cover at the top of the stove before use. Demands for the floor: The
foundation must be able to bear the stove and possibly the chimney’s weight.
INSTALLATION INSTRUCTIONS IN SMOKE CONTROL AREAS
Installation in a smoke control area requires the additional assembling / installation of the “Damper control unit” which must be installed by the installer. See drawing and picture on page 19.
LIGHTING INSTRUCTION
The first time The first time the stove is lit is must be done gently as all the materials need to get use to the heat. The Senotherm varnish that the stove is painted with will harden the first couple of times the stove is heated, and it may cause some odour nuisances. So make sure that you have proper ventilation. Do not touch the painted surface, when the stove is hot. The painting has to harden up first.
Use of the stove
Below is the procedure used for testing/approval of the stove. It is this
procedure that will lead to the best combustion for the given chimney.
Firewood amount and damper setting can be adjusted to the individual need for
heating and the draught in the concrete chimney. On your new TT22 the work
with controlling the air input has been simplified so there is only one
knob/damper (below the door). Between the left position and the middle
position you have the normal area where you control the air input.
No air input = left position and
Maximum air input = middle position.
As help for lighting the control knob/damper can be pushed down a little and
pushed completely to the right. This start help adds some air from below and
ensures faster lighting. After a few minutes the control knob/damper is
returned to the normal position (between the left and middle position).
Lighting and continuous firing at EN-testing
- The damper/start-up device can be opened (the knob is pushed down and to the right) for a few minutes at lighting. Put about 12-15 kindling sticks (dia. 2-5 cm) in the bottom of the stove, laid in a criss-cross pattern as a log house. Put 2 firelighters in the middle and light them.
- Leave the door ajar so there is an opening of about 1 cm. Leave the stove like that for about 8-10 minutes before you close the door completely. Stay by the stove as long as the door is ajar.
- When the fire has burned to embers (there are no more flames) open the door gently so the ash is not whirled out through the door. Gently spread out the embers with a poker so they are even.
- Put 2-4 pieces of firewood in the stove, about 2,0 to 2,5 kg total. The pieces are put in the bottom of the stove and parallel to the front of the stove with equal distance to the stove’s sides and with mutual distance of about 1 cm. The front piece is best lit if it has a split side that is turned to the door and one in the embers. Close the door completely immediately. Make sure you don’t overfill the chamber, max.15 cm from the bottom plate of the combustion chamber.
- The knob/damper is opened so it is about 2/3 open (between the left and middle position) and after about 2 minutes the damper is set to about 1/3 open. How much the damper should be open depends on the individual chimney’s draught, but the flames should now stabilise to a calm fire.
- When the wood has burned to embers (after about 45-60) you start again from point 3.
MAINTENANCE always use original parts
Maintenance and cleaning of the stove should only be performed when the stove is cold. The daily maintenance is limited, but once a year the stove should get thorough maintenance. The combustion chamber should be cleaned for ashes and soot and the door hinges and the closing mechanism should be lubricated with copper grease.
The surface is maintained by brushing it with a soft, long-haired brush or by using the vacuum cleaner with a brush. The stove can also be dusted with a duster. Always remember: only when the stove is cold.
Jointings can look okay, but they collapse under the heat and thereby lose the ability to keep the stove sealed. Jointings should be changed as needed as it is important to good combustion and a clean window that the stove is sealed.
The insulation plates in the combustion chamber that are broken or worn can easily be changed as they are loosely fixed. The material used is called Vermiculite and is a porous, but very suitable insulation material. It has no effect on the stove’s efficiency that the insulation cracks. However, it should be changed when the wear surpasses half of the original thickness.
Painting the stove with Senotherm-spray can cover spots or small
scratches from kettles and such. Larger damages needs to be ground with fine
steel wool, vacuumed and then sprayed. The can has to be shaken vigorously and
then sprayed on at a distance of 15-20 cm. It is very important that the stove
is not in use and completely cold before you use the spray due to the fire
hazard. In order to keep the stove’s varnished surfaces looking nice for years
to come you should try to avoid touching the varnished surfaces when the stove
is hot. Make sure to have sufficient ventilation when using spray paint.
Glass normally does not need any maintenance apart from cleaning. This is
most easily done by using TermaTech’s glass cleaner. Remember only to use
glass cleaner when the stove is cold. Glass is made of ceramic glass, be sure
of environmentally disposal.
Original part s which need to be changed due to wear can be found at your dealer. Because of fit etc. only original parts from TermaTech should be used. Right to claim compensation for defective product is under current law. When stating deviations the use of the product must be suspended immediately and the dealer must be contacted. Chimney/Flues Must be swept on regular occasions, as per manufacturers recommendations.
5 YEAR WARRANTY* / RIGHT TO INVOKE LACK OF CONFORMITY
If defects/faults are ascertained, use of the wood burner must be stopped immediately and the dealer contacted.
*5 Year warranty
Provided that there has been normal operation of the wood burner, TermaTech
offers a 5 year warranty on material and manufacturing faults on the load-
bearing frame, exclusive of the combustion chamber.
Combustion chamber:
The following parts are not covered by the warranty: The combustion chamber,
Cast iron parts (bottom, door and grate), Insulation material (vermiculite
plates), Smoke deflector plates, Glass, gaskets as well as the closing
mechanism/handle.
Exterior parts:
The following parts are not covered by the warranty: Varnished
plates/surfaces, stone facings, glazed tiles, concrete and glass as well as
the closing mechanism/ handle The warranty does not cover faults which are due
to: · the user/mounting guide not being followed
- the mounting being carried out incorrectly
- overheating/deterioration of the materials, caused by the use of, for example, the incorrect type of fuel, petroleum coke or too much fuel
- the product has been connected to a chimney with poor drawing qualities, for example, chimneys that are too short or are leaking
- the product being positioned or has been positioned/kept in unheated or damp surroundings
- the product being in bad repair or not maintained in accordance with the instructions
- normal wear and tear of wearing parts/expendable items as well as the varnish
- similar circumstances which are not due to material or manufacturing faults
The lesser defects below, which cannot underlie any claim, can occur in the product:
- naturally occurring variations in the colour nuances and marbling on the soapstone, sandstone and other stone cladding.
- sounds which occur during burning are normal, this occurs when metal expands/retracts.
If a fault occurs during delivery to the customer, or if such a fault arises during the warranty period which is covered by this warranty, TermaTech A/S agrees to send a suitable replacement part free of charge to rectify the fault. Any additional obligation of TermaTech A/S to remedy the fault, for example, in the form of installation of the replacement part, does not exist. In addition the purchaser has, apart from the right to a replacement part, no right to either direct or indirect damages.
Repairs of faults or replacement of parts on the product do not extend the product or replacement part’s warranty period. Neither does a new warranty period begin for the product or replaced part.
Apart from the above warranty rules, the consumer also has those rights which are evident from the obligatory consumer legislation Any fault or defect must be examined by the vendor who has sold the product. In this case the purchaser must be able to prove that the product has been purchased via the vendor and when it was purchased, for example, in the form of an invoice/receipt. The purchaser must specify the model and production number, which is stated on the product. If the purchaser wishes to refer to a fault, the vendor must be informed within a reasonable time, i.e. 14 days after the defect has been ascertained.
HINTS
Lighting after long break If the stove has not been used for a long time the chimney should be checked for possible blockage before lighting. Furthermore it is a good idea to remove any dust from the wood-burning stove as it might smell after a long break.
Chimney fire
In case of chimney fire the doors, drawers and damper of the wood-burning
stove must be closed immediately in order to shut of the supply of oxygen. The
relevant authorities must be notified if necessary. The stove must not be used
until the chimney has been inspected. Kindling is the designation for finely
split wood/sticks that are about 20-30cm long and have a diameter of 2-5cm.
Wood like birch, beech, oak, ash, elm, pine wood and wood from fruit trees is all suitable for splitting into firewood.
Waste products like pressure-treated wood, chipboard, coloured brochure or glossy paper must not be used in a wood-burning stove. They develop hydrochloric acid or heavy metals which cause a lot of damage to the stove and the environment.
Firewood should have a diameter of 7-9 cm and be no more than about 50 cm long, otherwise it will get too close to the side of the stove (at the CE- testing firewood at a length of 28 cm was used). The most important thing for good combustion is that the wood is dry (15-20% moisture). If the firewood is too wet it is difficult to get it to burn, the chimney draught is nonexistent, there is a lot of smoke and the exploitation is lower as the water has to evaporate first. Furthermore there may be damage to the stove and the chimney in the shape of shining soot and tarry deposits. At worst it can cause a chimney fire. If the firewood is too dry it will burn too quickly. Often the gasses in the wood are released faster than they can burn and some go unburned through the chimney. This also gives lower exploitation and harms the environment. So it is a balance that is quite easy to find with a little practise. See also below under Storage.
Bio-briquettes can be used, but they develop a lot of ash and dust. Put
in max. 2-3 kg per hour. PLEASE NOTE – Bio-Briquettes can NOT be used within a
Smoke Control Areas.
Energy coke must not be used as it contains a lot of sulphur which wears
on a stove, the chimney and the environment. The life of stove and chimney
will be significantly reduced by using this firing type and the right to claim
compensation for the product is void.
Storage of the firewood is best under a roof, however with good
ventilation, e.g. in a carport or under a shed roof. Place the wood on a
wooden pallet or the like so it is free from the ground. Fresh wood that has
been sawed and split must be stored for about 1-2 years this way until the
moisture in the wood is down to 15-20%.
The ashes can be put in the rubbish bin for garbage collection. The ashes
should always have cooled for 1-2 days before it is put in the rubbish bin, as
there might still be embers that can light garbage or a garbage bag.
Regulation and smoke damper
If one is fixed in the chimney it should not close of more than 80% of the
internal diameter of the chimney.
MALFUNCTIONS
If problems should occur with the use of the stove the cause can possibly be found below. If not, then you are always welcome to contact your dealer.
The stove is difficult to control it burns too fast
If the stove is new, then check that the directions have been followed. If the
stove is more than 1 year old or if it has been used heavily, then the
jointings may need to be changed. If the jointings sit for too long the heat
makes them lose their ability to keep the stove sealed. If there is heavy
draught in the chimney it may be necessary to fit a damper in it.
The stove has poor draught after installation
Check that the mounting instructions have been followed. It is especially the
conditions surrounding the chimney that may cause problems. Are diameter and
length okay, is it sealed, are smoke pipe and junctions sealed? Is the
cleaning hatch sealed? You may need to contact a chimney sweep to remedy the
problem as the chimney may be blocked.
Smoke and soot smell
This can be caused by down-draught in the chimney and most often happens in
specific wind directions. The chimney may be too short for the ridge or trees
may have grown and are creating turbulence. Remember not to open the door
while there are flames.
The stove is difficult to light and may die out
There may be a number of causes. The most typical are:
- The damper is not sufficiently open.
- The firewood is too wet.
- The draught in the chimney is too small or maybe it is blocked or leaking.
- The ember layer was too small/incinerated and did not give enough heat to light the logs.
Possibly give some start-up air to the fire by opening the damper (pushed down and to the right) to get the stove going again. Then the damper has to be closed again (back to position between left and the middle).
Depending on the problem it may be necessary to contact the dealer, installer or a chimney sweep.
The glass soots up
The wood is too moist.
Lack of draught in the chimney.
Check that the damper is not closed.
Door is closed too early at lighting (point 3 section 2).
TECHNICAL SPECIFICATIONS
| TT22| TT22R| TT22H| TT22RP
---|---|---|---|---
Nominal heat output:| 7,5 kW| 7,5 kW| 7,5 kW| 7,5 kW
Height:| 929mm| 958mm| 1093mm| 1006mm
Width:| 708mm| 756mm| 756mm| /56mm
Depth:| 482mm| 482mm| 482mm| 469mm
Weight ca.:| 168kg| 169kg| 195kg| 205kg
| TT22S| TT22HS| TT22HST| TT22RPS
---|---|---|---|---
Nominal heat output:| 7,5 kW| 7,5 kW| 7,5 kW| 7,5 kW
Height:| 949mm| 1093mm| 1162mm| 1006mm
Width:| 708mm| 756mm| 756mm| /56mm
Depth:| 482mm| 482mm| 482mm| 469mm
Weight ca.:| 203kg| 252kg| 322kg| 273kg
Average values for testing of TT22 models:
Exhaust gas temperature | 259 °C |
---|---|
Exhaust gas mass flow | 6,2 g/s |
Efficiency | 82% |
Nominal Heat output | 7,5 kW |
Flue draught | 12 Pa |
SUPPLEMENTARY INSTRUCKTIONS UK
READ THE INSTRUCTION BOOKLET AND THESE SUPPLEMENTARY INSTRUCTIONS CAREFULLY
BEFORE INSTALLATION
These instructions together with those in the instruction booklet cover the
basic principles to ensure the satisfactory installation of the stove,
although detail may need slight modification to suit particular local site
conditions. In all cases the installation must comply with current Building
Regulations, Local Authority Byelaws and other specifications or regulations
as they affect the installation of the stove. It should be noted that the
Building Regulations requirements may be met by adopting the relevant
recommendations given in British Standards BS 8303, BS EN 15287-1:2007 as an
alternative means to achieve an equivalent level of performance to that
obtained following the guidance given in Approved Document J.
Please note that it is a legal requirement under England and Wales Building Regulations that the installation of the stove is either carried out under Local Authority Building Control approval or is installed by a Competent Person registered with a Government approved Competent Persons Scheme. HETAS Ltd operate such a Scheme and a listing of their Registered Competent Persons can be found on their website at www.hetas.co.uk.
CO Alarms:
Building regulations require that when ever a new or replacement fixed solid
fuel or wood/biomass appliance is installed in a dwelling a carbon monoxide
alarm must be fitted in the same room as the appliance. Further guidance on
the installation of the carbon monoxide alarm is available in BS EN 50292:2002
and from the alarm manufacturer’s instructions. Provision of an alarm must not
be considered a substitute for either installing the appliance correctly or
ensuring regular servicing and maintenance of the appliance and chimney
system.
The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act local authorities may declare the whole or part of the
district of the authority to be a smoke control area. It is an offence to emit
smoke from a chimney of a building, from a furnace or from any fixed boiler if
located in a designated smoke control area. It is also an offence to acquire
an “unauthorised fuel” for use within a smoke control area unless it is used
in an “exempt” appliance (“exempted” from the controls which generally apply
in the smoke control area).
In England appliances are exempted by publication on a list by the Secretary
of State in accordance with changes made to sections 20 and 21 of the Clean
Air Act 1993 by section 15 of the Deregulation Act 2015. In Scotland
appliances are exempted by publication on a list by Scottish Ministers under
section 50 of the Regulatory Reform (Scotland) Act 2014. Similarly, In
Northern Ireland appliances are exempted by publication on a list by the
Department of Agriculture, Environment and Rural Affairs under Section 16 of
the Environmental Better regulation Act (Northern Ireland) 2016. In Wales
appliances are exempted by regulations made by Welsh Ministers.
The TermaTech TT22, TT22R, TT22H, TT22S, TT22HS, TT22HST and TT22RP have
beenrecommended as suitable for use in smoke control areas when burning wood
logs and when fitted with a smoke control kit (damper control unit) to fix the
primary air control at 250mm2 and secondary air control at 440mm2 in their
minimum position (to prevent closure of the primary and secondary air controls
beyond the 25% open position).
Further information on the requirements of the Clean Air Act can be found
here: https://www.gov.uk/smoke-control-area-rules
HEALTH AND SAFETY PRECAUTIONS
Special care must be taken when installing the stove such that the
requirements of the Health and Safety at Work Act are met.
Handling
Adequate facilities must be available for loading, unloading and site
handling.
Fire Cement
Some types of fire cement are caustic and should not be allowed to come into
contact with the skin. In case of contact wash immediately with plenty of
water.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any
asbestos in the course of installation then please seek specialist guidance
and use appropriate protective equipment.
Metal Parts
When installing or servicing this stove care should be taken to avoid the
possibility of personal injury.
STOVE PERFORMANCE
Please refer to the table in the main instruction manual for details of the
stoves’ performances PREPARATORY WORK AND SAFETY CHECKS
IMPORTANT WARNING
This stove must not be installed into a chimney that serves any other heating
appliance.
There must not be an extractor fan fitted in the same room as the stove as
this can cause the stove to emit fumes into the room.
Chimney
In order for the stove to perform satisfactorily the chimney height must be
sufficient to ensure an adequate draught of approximately 15 Pa so as to clear
the products of combustion and prevent smoke problems into the room.
NOTE: A chimney height of not less than 4.5 metres measured vertically
from the outlet of the stove to the top of the chimney should be satisfactory.
Alternatively the calculation procedure given in EN 13384-1 may be used as the
basis for deciding whether a particular chimney design will provide sufficient
draught. The outlet from the chimney should be above the roof of the building
in accordance with the provisions of Building Regulations Approved Document J.
If installation is into an existing chimney then it must be sound and have no
cracks or other faults which might allow fumes into the house. Older
properties, especially, may have chimney faults or the cross section may be
too large i.e. more than 230 mm x 230 mm. Remedial action should be taken, if
required, seeking expert advice, if necessary. If it is found necessary to
line the chimney then a flue liner suitable for solid fuel must be used in
accordance with Building Regulations Approved Document J.
Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of the stove. If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire. If there is no existing chimney then any new system must be to the designation described above and in accordance with Building Regulations Approved Document J.
A single wall metal fluepipe is suitable for connecting the stove to the
chimney but is not suitable for use as the complete chimney. The chimney and
connecting fluepipe must have a minimum diameter of 150 mm and its dimension
should be not less than the size of the outlet socket of the stove.
Any bend in the chimney or connecting fluepipe should not exceed 45°. 90°
bends should not be used.
Combustible material should not be located where the heat dissipating through
the walls of fireplaces or flues could ignite it. Therefore when installing
the stove in the presence of combustible materials due account must be taken
of the guidance on the separation of combustible material given in Building
Regulations Approved Document J and also in these stove instructions.
If it is found that there is excessive draught in the chimney then a draught
stabiliser should be fitted. Fitting of a draught stabiliser will affect the
requirement for the permanent air supply into the room in which the stove is
fitted in accordance with Approved Document J (see also combustion air
supply).
Adequate provision e.g. easily accessible soot door or doors must be provided
for sweeping the chimney and connecting fluepipe where it is not intended for
the chimney to be swept through the appliance.
Hearth
The hearth should be able to accommodate the weight of the stove and its
chimney if the chimney is not independently supported. The weight of the stove
is indicated in the brochure.
The stove should preferably be installed on a non-combustible hearth of a size
and construction that is in accordance with the provisions of the current
Building Regulations Approved Document J.
The clearance distances to combustible material beneath, surrounding or upon
the hearth and walls adjacent to the hearth should comply with the guidance on
the separation of combustible material given in Building Regulations Approved
Document J and also in these stove instructions.
If the stove is to be installed on a combustible floor surface, it must be covered with a non-combustible material at least 12mm thick, in accordance with Building Regulations Approved Document J, to a distance of 30 cm in front of the stove and 15 cm to each side measuring from the door of the combustion chamber.
Combustion air supply
In order for the stove to perform efficiently and safely there must be an
adequate air supply into the room in which the stove is installed to provide
combustion air. The provision of air supply to the stove must be in accordance
with current Building Regulations Approved Document J. An opening window is
not appropriate for this purpose.
Connection to chimney
Stoves may have a choice of either a rear or top flue gas connector that
allows connection to either a masonry chimney or a prefabricated factory made
insulated metal chimney in accordance with their instructions. In some cases
it may be necessary to fit an adaptor to increase the diameter of the flue to
the minimum required 150 mm section of the chimney or liner.
Commissioning and handover
Ensure all parts are fitted in accordance with the instructions.
On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out, before lighting the stove. Once the stove is under fire check all seals for soundness and check that the flue is functioning correctly and that all products of combustion are vented safely to atmosphere via the chimney terminal.
On completion of the installation and commissioning ensure that the operating instructions for the stove are left with the customer. Ensure to advise the customer on the correct use of the appliance and warn them to use only the recommended fuel for the stove.
Advise the user what to do should smoke or fumes be emitted from the stove. The customer should be warned to use a fireguard to BS 8423:2002 (Replaces BS 6539) in the presence of children, aged and/or infirm persons.
READ THE INSTRUCTION BOOK AND THESE INSTRUCTIONS CAREFULLY BEFORE USING THE STOVE
WARNING NOTE
Properly installed, operated and maintained this stove will not emit fumes
into the dwelling. Occasional fumes from de ashing and re fuelling may occur.
However, persistent fume emission is potentially dangerous and must not be
tolerated. If fume emission does persist, then the following immediate action
should be taken:
(a) Open doors and windows to ventilate the room and then leave the premises.
(b) Let the fire go out.
(c) Check for flue or chimney blockage and clean if required
(d) Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected. If necessary seek expert advice.
The most common cause of fume emission is flueway or chimney blockage. For your own safety these must be kept clean at all times.
IMPORTANT NOTES
General
Before lighting the stove check with the installer that the installation work
and commissioning checks described above have been carried out correctly and
that the chimney has been swept clean, is sound and free from any
obstructions. As part of the stoves’ commissioning and handover the installer
should have shown you how to operate the stove correctly.
CO Alarm
Your installer should have fitted a CO alarm in the same room as the
appliance. If the alarm sounds unexpectedly, follow the instructions given
under “Warning Note” above.
Use of fireguard
When using the stove in situations where children, aged and/or infirm
persons are present a fireguard must be used to prevent accidental contact
with the stove. The fireguard should be manufactured in accordance with BS
8423:2002 (Replaces BS 6539).
Chimney cleaning The chimney should be swept at least twice a year. It is important that the flue connection and chimney are swept prior to lighting up after a prolonged shutdown period.
If the stove is fitted in place of an open fire then the chimney will require sweeping after a month of continuous operation. This is a precaution to ensure that any “softer” deposits left from the open fire usage have not been loosened by the higher flue temperatures generated by the closed stove.
In situations where it is not possible to sweep through the stove the installer will have provided alternative means, such as a soot door. After sweeping the chimney the stove flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush.
Periods of Prolonged Non-Use
If the stove is to be left unused for a prolonged period of time then it
should be given a thorough clean to remove ash and unburned fuel residues. To
enable a good flow of air through the appliance to reduce condensation and
subsequent damage, leave the air controls fully open.
Extractor fan
There must not be an extractor fan fitted in the same room as the stove as
this can cause the stove to emit smoke and fumes into the room.
Aerosol sprays
Do not use an aerosol spray on or near the stove when it is alight.
Use of operating tools
Always use the operating tools provided when handling parts likely to be hot
when the stove is in use.
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel
charge, excessive smoke emission can occur. Refuelling must be carried out
onto a sufficient quantity of glowing embers and ash that the new fuel charge
will ignite. If the fire bed is too low or cool, suitable kindling must be
used to re-light fires
Fuel overloading The maximum amount of fuel specified in this manual
should not be exceeded, overloading can cause excess smoke.
Use with door left open
Operation with the door open can cause excess smoke. The appliance must not be
operated with the appliance door left open except as directed in the
instructions.
Dampers left open
Operation with the air controls or dampers open can cause excess smoke. The
appliance must not be operated with air controls or dampers left open except
as directed in the instructions.
Chimney Fires
If the chimney is thoroughly and regularly swept, chimney fires should not
occur. However, if a chimney fire does occur turn off the stove immediately
and isolate the mains electricity supply (if applicable), and tightly close
the doors of the stove. This should cause the chimney fire to go out. If the
chimney fire does not go out when the above action is taken then the fire
brigade should be called immediately. Do not relight the stove until the
chimney and flueways have been cleaned and examined by a professional.
Permanent air vent
The stove requires a permanent and adequate air supply in order for it to
operate safely and efficiently. In accordance with current Building
Regulations the installer may have fitted a permanent air supply vent into the
room in which the stove is installed to provide combustion air. This air vent
should not under any circumstances be shut off or sealed.
USER OPERATING INSTRUCTIONS
Please read the important notices given above before referring to the main
instruction book for detailed operating instructions.
Recommended fuels Stoves may be designed to burn dry seasoned wood logs and/or
solid mineral fuel as indicated in the main stove manuals.
HETAS Ltd Approval
HETAS approval may be limited to specific fuel types as detailed in the main
instruction manuals. Approval does not cover the use of other fuels either
alone or mixed with the recommended fuel, nor does it cover instructions for
the use of other fuels.
Damper control unit for smoke control areas
Declaration of Performance
TT22-CPR-2013-Version 6
Product:
Product type/application: Room heater burning solid fuel without hot water
supply
Type:
TT22: S01-640/641, TT22S: S01-642/643, TT22H: S01-644/645, TT22HS:
S01-646/647, TT22R: S01-648/649 TT22HST: S01-650/651 TT22RP: S01-654, TT22RPS:
S01-656 TT22HS: Black S01-658, TT22HS-BS S01-660
Fuel: Wood
Productions no. Please see nameplate on the back of the oven
Manufacturer:
TermaTech A/S Gunnar Clausens Vej 36 8260 Viby J Denmark
E-mail: info@termatech.com
Web: www.termatech.com
Tel.: +45 8742 0035
Certification and requirements:
AVCP system: System 3
European standard: CE/DS/EN 13240:2001 + A2:2004
Certification: Teknologisk Institut, notified body no. 1235, has performed
determination of the product type and declared performance on the basis of
type testing and issued test report no. TI 300-ELAB-1778-EN + 300-ELAB-1778
-EN-Rev-1
Declared performance:
Essential characteristics| Performance| Harmonised technical
specification
---|---|---
Reaction to fire| Al| CE/DS/EN A2:2004
Distance to combustible materials| Rear: min. min. 150 / 50 mm
Sides: min. 450 mm
To the corner 450: min. 150 mm
Other safety distances — please see User and mounting manual
Emission of combustion products| CO = 0,07 %
NOx = 101 mg/Nm3 OGC = 95 mgC/Nm3 PM = 14 mg/Nm3
Electrical safety| NPD
Maximum operating pressure| NPD
Risk of burning fuel falling out| Passed
Surface temperature| Passed
Clean ability| Passed
Mechanical strength| Passed
Emission of hazardous materials| Passed
Flue gas temperature| 259° Celsius
Output| 7,5 KW
Energy efficiency| 82%
The undersigned is responsible for the manufacturing and conformity with the declared performance.
Viby 7.3.2013
Søren Toft
Installation instructions TT22HST Mounting the soapstone panels UK
DE Seite 1: UK Page 2: FR Page 3: DK Side 4:
Read these instructions carefully before installing your new wood-burning
stove. Also read the provided installation and user instructions for the TT22
stove series.
Note: The size of the stones may vary slightly, making it necessary to
adjust the various parts. The stones are a natural material, so there will be
differences in colours and patterning.
-
Start by positioning the stove in the desired location in the home. If it has been decided to use a shaped floor plate, remember to mount the provided adjustable feet under the stove (stored in the ash drawer or fuel compartment).
-
Unpack the stones. The photo above shows the stone parts included (take care, as edges and corners can easily be damaged).
-
The two front stones are identical, so it does not matter which stone goes at the bottom or top.
-
For mounting, use a 4mm and a 6mm Allen key. A little socket spanner and a 10mm top.
-
Bottom stone: Fit the angle irons provided inside the fuel compartment. Mount and adjust the angles so the stones are in place and are flush with the edges of the stove.
-
Top front stone: The stone has three threaded holes for the provided bolts and washers.
-
Place the frontstone against the metal plate with the threaded holes in line with the prepared holes, and fix it in place with socket spanner and the 10mm top. Mount after that the bracket in the top. See the white arrow.
-
Heat retention stones: Position the 4 heat retention stones as shown here.
-
Side stones : To mount these, you will need 6mm Allen key. To fix the stones, use the provided fittings with metal pin and the 8mm Allen screws and washers. You will be able to adjust the stones outwards. Make sure they are equal distances from the sides of the stove.
-
Top stone : The top stone should be loosely placed on the top, with the prepared holes matching the mounted threaded studs with fitted nuts.
www.termatech.com
TermaTech AS • DK-8260 Viby J. • Tlf: +45 8742 0035
www.termatech.com
TermaTech AS • DK-8260 Viby J. • Tlf: +45 8742 0035
99-230 version 03.2022
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>