puravent PMSF09 Split-type Room Air Conditioner Owner’s Manual
- June 5, 2024
- puravent
Table of Contents
- puravent PMSF09 Split-type Room Air Conditioner
- Read This Manual
- Safety Precautions
- Prior to Operation
- Usage
- Cleaning and maintenance
- Service
- Operating temperature
- PARTS DESCRIPTION
- ADJUSTING AIR FLOW DIRECTION
- HOW THE AIR CONDITIONER WORKS
- MAINTENANCE
- Maintenance
- OPERATION TIPS
- Troubleshooting tips
- SERVICE WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
puravent PMSF09 Split-type Room Air Conditioner
Read This Manual
Inside you will find many helpful hints on how to use and maintain your
air conditioner. Just a little preventative care on your part can save you a
great deal of time and money over the life of your air conditioner.
You’ll find many answers to common problems in the chart of troubleshooting
tips. If you review the chart of Troubleshooting Tips first, you may not need
to call for service.
CAUTION
- Contact an authorized service technician for repair or maintenance of this unit. Contact the installer for installation of this unit.
- The air conditioner is not intended for use by young children or invalids without supervision.
- Young children should be supervised to ensure that they do not play with the air conditioner.
- If the power cord is to be replaced, replacement work must be performed by authorized personnel only.
- Installation work must be performed in accordance with the national wiring standards and by authorized personnel only.
Safety Precautions
To prevent injury to the user or other people and property damage, the
following instructions must be followed.
Ignoring the operating instructions may cause harm or damage.
The seriousness is classified by the following indications.
WARNING: This symbol indicates the possibility of death or serious
injury.
CAUTION This symbol indicates the possibility of injury or damage to
property.
Meanings of symbols used in this manual are as shown below.
- Never do this.
- Always do this.
WARNING
- Connect with the power properly.
- Do not modify power cord length or share the outlet with other appliances Always ensure effective earthing.
- Disconnect the power if strange sounds, smell, or smoke comes from it.
- Keep firearms away.
- Ventilate room before operating air conditioner if there is a gas leakage from another appliance.
- Otherwise, it may cause electric shock or fire due to excess heat generation.
- It may cause electric shock or fire due to heat generation.
- No earthing may cause electric shock.
- It may cause fire and electric shock.
- It may cause fire.
- It may cause explosion, fire and, burns.
- It may cause electric shock or fire due to heat generation.
- It may cause electric shock.
- It may cause failure of machine or electric shock.
- It may cause fire and electric shock.
- It may cause fire and electric shock.
- It may cause electric shock or fire.
- This could damage your health.
- No installation may cause fire and electric shock.
- It may cause electric shock.
- It may cause an explosion or fire.
- It may cause failure and electric shock.
- Do not operate or stop the unit by inserting or pulling out the power plug.
- Do not operate with wet hands or in damp environment.
- Do not allow water to run into electric parts.
- Do not use the socket if it is loose or damaged.
- Do not use the power cord close to heating appliances.
- Do not damage or use an unspecified power cord.
- Do not direct airflow at room occupants only.
- Always install circuit breaker and a dedicated power circuit.
- Do not open the unit during operation.
- Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
CAUTION
- When the air filter is to be removed, do not touch the metal parts of the unit.
- It may cause an injury.
- Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury.
- Operation with windows opened may cause wetting of indoor and soaking of household furniture.
- When the unit is to be cleaned, switch off, and turn off the circuit breaker.
- Stop operation and close the window in storm or hurricane.
- Use caution when unpacking and installing. Sharp edges could cause injury.
- Do not clean the air conditioner with water.
- Water may enter the unit and degrade the insulation. It may cause an electric shock.
- This could injure the pet or plant.
- Failure to do so may cause electric shock and damage.
- Do not put a pet or house plant where it will be exposed to direct air flow.
- Hold the plug by the head of the power plug when taking it out.
- Ventilate the room well when used together with a stove, etc.
- An oxygen shortage may occur.
- Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects.
- It may cause deterioration of quality, etc.
- It may cause failure of product or fire.
- Do not use for special purposes.
- Turn off the main power switch when not using the unit for a long time.
- If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician.
- It may cause failure of appliance or accident.
- Appearance may be deteriorated due to change of product color or scratching of its surface.
- Do not place obstacles around air-inlets or inside of air-outlet.
- Do not use strong detergent such as wax or thinner. Use a soft cloth for cleaning.
- If bracket is damaged, there is concern of damage due to the unit falling.
- There is danger of fire or electric shock.
- Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure.
- Do not place heavy object on the power cord and take care so that the cord is not compressed.
- Operation without filters may cause failure.
- It contains contaminants and could make you sick.
- Always insert the filters securely.
- Clean filter once every two weeks.
Prior to Operation
- Contact an installation specialist for installation.
- Make sure the unit is grounded efficiently.
- Do not use a damaged or non-standard power cord.
- Do not share the same outlet with other appliances.
- Do not use an extension cord.
- Do not start/stop operation by shutting off the power supply.
Usage
-
Exposure to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for
extended periods of time. -
Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or other heating devices.
-
Do not use this air conditioner for non-specified special purposes (e.g. Preserving precision devices, food, pets, plants, and art objects). Usage in such a manner could harm such property.
Cleaning and maintenance
- Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
- Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
- When cleaning the unit, first make sure that the power and circuit breaker are turned off.
Service
For repair and maintenance, contact your authorized service dealer.
Operating temperature
Mode
Temperature| Cooling operation| Heating operation| Drying operation
---|---|---|---
Room temperature| 17 C ~| 32 C| 17 C ~| 30 C| 17 C ~| 32 C
Outdoor temperature|
18 C ~
|
43 C
| -7 C ~| 24 C| 18 C ~| 43 C
CAUTION:
- If air conditioner is used outside of the above conditions, certain safety protection features may come into operation and cause the unit to function abnormally.
- Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
- Optimum performance will be achieved within these operating temperature.
PARTS DESCRIPTION
Indoor unit
-
Front panel
-
Air inlet
-
Air filter
-
Air outlet
-
Horizontal air flow grille
-
Vertical air flow louver
-
Display panel
-
Remote controller signal receiver
-
Remote controller
-
Manual control button
Outdoor unit -
Connecting pipe, drain hose
-
Air inlet (side and rear)
-
Air outlet
The operation indicator lights flash rapidly (five times per second.) when safety protection features come into operation.
Note:
The pictures in this manual are for explanation purposes only and may not
correspond to the actual appearance of the air conditioner purchased.
Function indicators on indoor unit display panel
-
AUTO indicator.
This indicator illuminates when the air conditioner is in AUTO operation. -
DEFROST indicator (For Cooling & Heating models only)
This indicator illuminates when the air conditioner starts defrosting automatically or when the warm air control feature is activated in heating operation. -
TEMPERATURE indicator
Displays the temperature settings when the air conditioner is operational. -
OPERATION indicator
This indicator flashes after power is on and illuminates when the unit is in operation. -
TIMER indicator
This indicator illuminates when TIMER is set ON/OFF.
MANUAL OPERATION
Manual operation can be used temporarily in case you can not find the remote controller or its batteries are exhausted.
- Open and lift the front panel up to an angle until it remains fixed with a clicking sound.
- One press of the manual control button will lead to the forced AUTO operation.
- Close the panel firmly to its original position.
CAUTION:
- Once you push the manual button, the operation mode is shifted in an order as: AUTO, COOL, OFF.
- Push the button twice, the unit will operate in forced COOLING mode. This is used for testing purposes only .
- Third press will stop the operation and turn off the air conditioner operation.
- To restore the remote controller operation, use the remote controller directly.
OPTIMAL OPERATION
To achieve optimal performance, please note the following:
-
Adjust the air flow direction correctly so that it is not directed at people.
-
Adjust the temperature to achieve the best comfort level. Do not adjust the unit to excessive temperature levels.
-
Close doors and windows on COOL or HEAT modes, or performance may be reduced. Use TIMER ON button on the remote controller to select a time you want to start your
air conditioner. -
Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the air conditioner may stop running.
-
Clean the air filter periodically, otherwise cooling or heating performance may be reduced.
-
Do not operate unit with horizontal louvre in the closed position.
ADJUSTING AIR FLOW DIRECTION
- Adjust the air flow direction correctly otherwise, it might cause discomfort or cause uneven room temperatures.
- Adjust the horizontal louver using the remote controller.
- Adjust the vertical louver manually.
Adjusting the Vertical Air Flow Direction (up – down)
The air conditioner automatically adjusts the vertical air flow direction in
accordance with the operating mode.
To set the vertical air flow direction
Perform this function while the unit is in operation. Keep pressing the AIR
DIRECTION button on the remote controller to move the louver to the desired
position.
- Adjust the vertical air flow direction to the desired position.
- In subsequent operations, the vertical air flow is automatically set in the direction to which you adjusted the louver by pressing the AIR DIRECTION button.
To set the horizontal air flow direction (left – right)
Adjust the vertical louver manually using the lever on the left or right side
of the vertical louver arm (Depending on model). Take care not to catch
fingers on the fan, horizontal louver or to damage vertical louvers. When the
air conditioner is in operation and the horizontal louver is in
a specific position, move the lever at left (or right, depending on model) end
of the air outlet to the desired position.
To automatically swing the air flow direction (up – down)
Perform this function while the air conditioner is in operation.
- Press the SWING button on the remote controller.
- To stop the function, press the SWING button again. Press AIR DIRECTION button to lock louver in desired position.
CAUTION
- The AIR DIRECTION and SWING buttons will be disabled when the air conditioner is not in operation (including when the TIMER ON is set).
- Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dry mode. Otherwise, condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings.
- Do not move the horizontal louver manually. Always use the AIR DIRECTION or SWING button. If you move this louver manually, it may malfunction during operation. If the louver malfunctions, stop the air conditioner once and restart it.
- When the air conditioner is started immediately after it was stopped, the horizontal louver might not move for approximately 10 seconds.
- Open angle of the horizontal louver should not be set too small, as COOLING or HEATING performance may be impaired due to too restricted air flow area.
- Do not operate unit with horizontal louver in closed position.
- When the air conditioner is connected to power (initial power), the horizontal louver may generate a sound for 10 seconds, this is a normal operation.
HOW THE AIR CONDITIONER WORKS
AUTOMATIC OPERATION
- When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on what temperature you have selected and the room temperature.
- The air conditioner will control room temperature automatically around the temperature point set by you.
- If the AUTO mode is uncomfortable, you can select desired conditions manually.
SLEEP OPERATION
When you push SLEEP button during cooling, heating or AUTO operation , the air
conditioner will automatically increase (cooling) or decrease (heating) 1 per
hour. The set temperature will be steady 2 hours later
The fan speed will be automatically controlled.
DRYING OPERATION
- The dry mode will automatically select the drying operation based on the difference between the set temperature and the actual room temperature.
- The temperature is regulated while dehumidifying by repeating turning on and off of the cooling operation or fan only. The fan speed is LOW.
MAINTENANCE
WARNING: It is necessary to stop the air conditioner and dis-connect the power supply before cleaning.
Cleaning the indoor unit and remote controller
CAUTIONS:
- Use a dry cloth to wipe the indoor unit and remote controller.
- A cloth dampened with cold water may be used on the indoor unit if it is very dirty.
- The front panel of the indoor unit can be removed and cleaned with water. Then wipe it with a dry cloth. Do not use a chemically treated cloth or duster to clean the unit.
- Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause the plastic surface to crack or deform.
Cleaning the air filter
A clogged air filter reduces the cooling efficiency of this unit. Please clean
the filter once every 2 weeks.
-
Lift the indoor unit panel up to an angle until it stops with a clicking sound.
-
Take hold of the handle of the air filter and lift it up slightly to take it out from the filter holder, then pull it downwards.
-
Remove the AIR FILTER from the indoor unit.
-
Remove the Electrostatic Filter from its support frame as shown in the Figure on the left (Not applicable to the units without electrostatic filter).
- Do not touch this Electrostatic Filter within 10 minutes after opening the inlet grille, it may cause an electric shock.
- Clean the Electrostatic Filter with mild detergent or water and dry in the sunlight for two hours.
- Before re-install the Electrostatic Filter, check whether the corona line or support frame is damaged or not.
-
Install the air freshening filter back into position.
-
Insert the upper portion of air filter back into the unit taking care that the left and right edges line up correctly and place filter into position.
Maintenance
Checks before operation If you plan to idle the unit for a long time, perform the following:
- Operate the fan for about half a day to dry the inside of the unit.
- Stop the air conditioner and disconnect power. Remove the batteries from the remote controller.
- The outdoor unit requires periodic maintenance and cleaning. Do not attempt to do this yourself.
Contact your dealer or servicer.
Checks before operation
- Check that the wiring is not broken off or disconnected.
- Check that the air filter is installed.
- Check if the air outlet or inlet is blocked after the air conditioner has not been used for a long time.
CAUTIONS:
- Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
- Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
- When cleaning the unit, first make sure that the power and circuit breaker are turned off.
OPERATION TIPS
The following events may occur during normal operation.
-
Protection of the air conditioner Compressor protection
- The compressor cannot restart for 3 minutes after it stops.
- The unit is designed no t to blow cold air in HE AT mode, when the indoor heat exchanger is in one of the following three Situations and the set temperature has not been reached.
- When heating has just starting.
- Defrosting.
- Low temperature heating.
- The indoor or outdoor fan stop running when defrosting (Cooling and heating models only). Defrosting (Cooling and heating models only)
- Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low and humidity is high resulting in lower heating efficiency of the air conditioner.
- During this condition air conditioner will stop heating operation and start defrosting automatically. The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the amount of frost buildup on the outdoor unit.
-
A white mist coming out from the indoor unit
- white mist may generate due to a large temperature difference between air inlet and air outlet on COOL mode in an indoor environment that has a high relative humidity.
- white mist maybe due to moisture generated from the defrosting process when the ai r conditioner restarts in HEAT mode operation after defrosting.
-
Low noise of the air conditioner
- You may hear a low hissing sound when the compressor is running or has just stopped running. This sound is the refrigerant fl owing or comin g to a stop.
- You can also hear a low “squeak” sound when the compressor is running or has just stopped running. This is caused by heat expansion and cold contraction of the plastic parts in the unit when the temperature is changing.
- A noise may be heard due to louver restoring to its original position when power is first turned on.
-
Dust is blown out from the indoor unit.
This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit. -
A peculiar smell comes out from the indoor unit.
This is caused by the indoor unit giving off smells permeated from building material, from furniture, or smoke. -
The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and heating models only) mode.
When indoor temperature reaches the temperature setting on air conditioner, the compressor will stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating models only) to the set point. -
Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to
the maximum air outlet position and select HIGH fan speed. -
Heating mode (For cooling and heating models only)
The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation. When the outdoor temperature falls, heat drawn in by the air conditioner decreases accordingly. At the same time, heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature. If a comfortable temperature can’t be achieved by the air conditioner, we suggest you use a supplementary heating device. -
Auto-restart function
Power failure during operation will stop the unit completely.
For the unit without Auto-restart feature, when the power restores, the OPERATION indicator on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the remote controller. For the unit with Auto-restart feature, when the power restores, the unit restarts automatically with all the previous settings preserved by the memory function. -
Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. Disconnect the unit with power and then re-connect the unit with power again. Push the ON/OFF button on the remote controller to restart operation.
Troubleshooting tips
Malfunctions and Solutions
Stop the air conditioner immediately if one of the following faults occur. Disconnect the power and contact the nearest customer service center.
Trouble
- OPERATION indicator or other indicators flash rapidly(5 times every second) and this flash cannot be fixed by disconnecting the power, and then connect it again.
- Fuse blows frequently or circuit breaker trips frequently.
- Other objects or water penetrate the air conditioner.
- The remote controller won’t work or works abnormally.
- Other abnormal situations.
Malfunctions| Cause| What should be done?|
---|---|---|---
Unit does not start| Power cut| Wait for power to be restored.|
Unit may have become unplugged.| Check that plug is securely in wall
receptacle.|
Fuse may have blown.| Replace the fuse.|
Battery in Remote controller may have been exhausted.| ****
Replace the battery.
|
The time you have set with timer is incorrect.| ****
Wait or cancel timer setting.
|
Unit not cooling| Inappropriate temperature| Set temperature correctly. For|
or heating| setting.| detailed method please refer to|
(Cooling/ heating| | “Using remote control” section.|
models only)| | |
Air filter is blocked.| Clean the air filter.|
room very well|
Doors or Windows are open.| Close the doors or windows.|
while air flowing|
| |
out from the air| Air inlet or outlet of indoor or| Clear obstructions away
first, then|
conditioner| outdoor unit has been blocked.| restart the unit.|
| Compressor 3 minutes protection has been activated.| Wait.|
If the trouble has not been corrected, please contact a local dealer or the
nearest customer service center. Be sure to inform them of the detailed
malfunctions and unit model.|
Notes:
- Do not attempt to repair the unit yourself.
- Always consult an authorized service provider.
SERVICE WARRANTY
Do not operate the unit with a damaged cord or plug, after the unit
malfunctions, has been dropped or damaged.
For your convenience, record the complete model number and product name
(located on the Product Identification Plate), the date you purchased the
product, and attach your purchase receipt as proof of purchase.
To ensure your product is covered by warranty, the complete faulty product
together with your purchase receipt should be returned to your retailer.
ONE (1) YEAR LIMITED WARRANTY
Save This Warranty Information
EHS (International) Ltd. Guarantees this product free from defects in materials and workmanship for a period of one (1) year.
Should this unit be operated under conditions other than those recommended, at voltages other than the voltage indicated on the unit, or any attempts made to service or modify the unit, will render this WARRANTY VOID. The product you buy may sometimes differ slightly from illustration. This warranty is in addition to, and does not affect, your statutory rights.
Should you have a problem with this product, please call our Help Desk on: (0870) 742 5021.
This product has been manufactured to comply with EEC Directives 73/23/EEC and
89/336/EEC
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your Local Authority or
retailer for recycling advice.
Get In Touch
Call: 0845 6880112 Email: info@adremit.co.uk
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard, Settle, North Yorkshire,
BD24 9RH
Read User Manual Online (PDF format)