INTRODUCTION
1.1.Presentation of the product
The Controller is used to select the operating mode (CLOCK mode or COUNTER
mode) of the associated digital clocks.
In the CLOCK mode, the digital clock displays the local time and in the
COUNTER mode, the clock can be used as a STOPWATCH (counting up) or as a TIMER
(counting down).
The controller can be fitted with wired Start/Stop and Reset remote buttons
(maximum cable length = 20m).
The controller features a relay that is activated at the end of the count (up
or down) that can be used to control a buzzer or a warning light.
Green LEDs are used to identify the operating mode.
There are 2 versions of the controller:
– the wall mounting version | – the flush mounting version |
---|
|
The controller is compatible with both the current and previous models of Style clocks.
1.2. Synoptic
INSTALLATION
Leproduit must be installed only by qualified and authorized personnel.
2.1. Wall mounting
- Drill 4 holes Ø5 mm according to the following dimensions and insert the wall plugs.
- Flip-open both side flaps to have access to the holes A.
- Use 4 screws Ø3.5 mm to mount the controller on the wall.
- Close the controller.
The controller is shipped with the 5-meter cable already installed.
NOTE: In case of use of the Remote Start/Stop and Reset buttons or of a buzzer/indicator light, open the controller in order to have access to the connectors illustrated below. To open the cover, unlock both sides at the same time.
Recommendations
2.2. Flush mounting
The controller is shipped with the 5-meter cable already installed.
- Make a cut-out in the wall or partition according to the following pattern:
- Insert the 2 wall plugs Ø5
- Thread the cable through the cut-out and fix the controller to the wall with 2 screws Ø3.5. Use silicon to guarantee to waterproof.
NOTE: In case of use of the Remote Start/Stop and Reset buttons or of a buzzer/indicator light, remove the back cover to have access to the connectors illustrated below. To do so remove both screws A.
2.3 Electrical connections
Control of a Style clock
Connect the cable from the controller to the connector on the clock card,
taking care to match the color of the wires is shown below:
Control of multiple Style clocks
Up to 10 clocks can be connected to the controller. All 10 clocks will display
the exact same thing.
OPERATION
3.1. Keys identification
– DOWN key: select the TIMER mode (countdown).
– CLOCK key: selection the HOUR mode (local time display).
– UP key: select the STOPWATCH mode (counting up).
Next to each of these 3 keys are LEDs that turn green to let the user know
which mode is active.
Mode setting keys.
These keys are only active in timing mode (counting or countdown):
– HOUR – MIN and SEC keys: setting of the hours, minutes, and seconds in
counting modes (counting up or counting down).
– RESET key: active only in counting (up or down) mode and when this mode is
stopped. It reset the counter to 0 in stopwatch mode and to the starting value
in timer mode.
– SPLIT key: makes it possible to display the elapsed time during 5 seconds.
This key is active only in the counting modes.
– START/STOP key: starts and stops the counting process.
3.2. HOUR mode / COUNTER mode
In HOUR mode, the Style clock displays the current local time. In this mode,
the status of the counter (running or stopped) is kept.
The CLOCK key allows the user to switch between COUNTER mode and HOUR mode and
vice-versa.
- In HOUR mode only the CLOCK green LED is lit.
- In STOPWATCH mode only the green UP LED (or DOWN in the TIMER mode) is lit.
- In normal operation, only one LED can be lit at one time.
NOTE: When the counter is active, the return to the counter mode after going from counter mode to hour mode will always be to the initial model: UP>CLOCK>UP or DOWN>CLOCK>DOWN
3.3. STOPWATCH mode
The counter runs from 0 to the programmed value (default max value: 23 : 00
00)
- Pressing START/STOP during SPILT = Display the stopped value.
- The SPLIT and RESET keys are disabled when the counter is running.
- The counter keeps on running even when the mode is switched to HOUR.
3.4. TIMER mode
The counter counts down from the programmed value (default value 23: 00 00) to
0.
- Pressing START/STOP during SPILT = Display the stopped value.
- The SPLIT and RESET keys are disabled when the counter is running.
- The counter keeps on running even when the mode is switched to HOUR.
3.5. End of Count-up / Countdown
The counter stops when:
– the MAX value is reached in STOPWATCH mode,
– 0 is reached in TIMER mode.
At the end of the count, the relay is activated
3.6. Toggling between Stopwatch mode and Timer mode
One can switch between counting modes at any time by pressing the DOWN and UP
keys regardless if the counter is running or stopped.
3.7. Relay modes
There are 3 possible operating modes of the relay:
Mode 1: manual
At the end of the count (up or down) the relay is activated and stays
activated.
Only by pressing the START/STOP can the relay be deactivated.
To start a new count press RESET and START/STOP.
Mode 2: timed
At the end of the count (up or down) the relay is activated for a programmable
duration from 0 to 59s (the default value is set to 5s).
Only by pressing the START/STOP can the relay be manually deactivated if the
5s delay is not over.
To start a new count press RESET and then START/STOP.
Mode 3: automatic timed
At the end of the count (up or down) the relay is activated for a programmable
duration from 0 to 59s (the default value is set to 5s).
At the end of the 5s delay, the counter is reset automatically.
To start a new count press START/STOP. (The RESET of the counter is done
automatically).
3.8. Parameter setting of the relay
To access the menu technician press Reset first then Start/Stop and hold both
keys pressed for 7 seconds.
3.9. Setting the max value of the counter
To set the MAX value of the counter (hour, minute, and second) the counter
must be stopped and reset.
In STOPWATCH mode (UP), the counter must display “00: 00 00”
In the TIMER mode (DOWN) the counter must display the max value “23: 00 00”
(default value)
3.10. Saving the parameters
Each parameter is stored in internal memory, therefore the following data is
kept in case of power failure:
- MAX value,
- Relay mode,
- Value of the relay delay.
3.11. Backup of the counter value
In case of momentary power failure, the counter keeps on running for about 3
minutes. When the power is restored within these 3 minutes the counting
continues without having lost a second.
If during the power failure the counter has reached the end of counting when
the power is restored, the counter will be stopped and the relay will be
activated according to the parameter setting.
TECHNICAL CHARACTERISTICS
4.1. Dimensions
Wall version
4.2. Technical characteristics
Operating temperature ………… -5°C to +55°C
Protection………………………… Wall version: IP55/IK03
Flush version: IP65/IK03
Power supply…………………… 15 VDC supplied by the clock
Max consumption ……………… 30 mA
Weight…………………………………. Wall version: 133 g
Flush version: 190 g
Construction…………………………… Wall version: Polycarbonate casing
Polyester keypad
Flush version: Stainless steel front panel
Aluminum back cover
Polyester keypad
The product complies with the following directives:
– EMC 2014/30/EU
– LVD 2014/35/EU
The flush mounting version product complies with the cleaning requirements in
hospitals.