ROROSHETTA SENSE ROYAL Instruction Manual

June 5, 2024
ROROSHETTA

ROROSHETTA SENSE ROYAL

Installation instruction

TYPES OF VENTILATION

The product is manufactured for different types of ventilation.
Before installation, check which type of ventilation the product is intended for

Duct out + Recirculation (DR)
Balanced ventilation + Common Exhaust (BC)
External engine + Central ventilation (EC)

ROROSHETTA SENSE ROYAL - fig18

SAFETY

Read, understand and follow the instructions to avoid personal injury and product damage.
Warning levels

Danger indicates that an accident will occur if the instructions are not followed. The accident leads to serious personal injury or possibly death.
Warning indicates that an accident may occur if the instructions are not followed. The accident can lead to serious personal injury or possibly death.
Caution indicates that an accident may occur if the instructions are not followed. The accident can lead to personal injury

Installation and maintenance

Electrical connection to 230 VAC with protective earth.
Cut the power to the product by the circuit breaker before installation and maintenance.
The product is supplied with a cable and an earthed plug to be connected to an earthed wall socket. The wall socket must be installed by an authorized electrician.
To minimize the risk of accidents, permanent installation, replacement of cable racks or another type of connection must be carried out by an authorized electrician.
LED lights should be replaced with the original spare parts.
Please contact Customer service, see section Service and warranty

Warning! The distance between stove and product must be 50–80 cm for an electrical stove and 70–80 cm for a gas hob.
If a higher mounting height is recommended by the gas hob manufacturer, this must be taken into account.
Note! If the product shall be supplemented with a Power Control Unit (PCU) see separate section

Caution!
Class 3R laser is used as a component for the air quality sensor system. Service of the sensor unit should be done by Class 3R laser authorized personnel. Please contact Customer service, see section Service and warranty. In case of damage exposing the visible red laser beam, avoid direct eye exposure to the beam and do not inspect it with optical instruments

Caution!
Different wall and ceiling materials require different types of fasteners. If necessary, supplement with plugs and replace screws with those intended for the material.
Diversion of the exhaust air shall be carried out in accordance with regulations issued by the relevant authority

CONTENT IN DELIVERY

ROROSHETTA SENSE ROYAL - fig

Duct out + Recirculation (DR)

ACCESSORIES

ROROSHETTA SENSE ROYAL - fig1

PRIOR TO INSTALLATION

Note. If the product shall be supplemented with a Power Control Unit (PCU) see separate section

ROROSHETTA SENSE ROYAL - fig2

INSTALLATION

ROROSHETTA SENSE ROYAL - fig3ROROSHETTA SENSE
ROYAL - fig4

POWER AND IO UNIT

CONNECTION DIAGRAM

ROROSHETTA SENSE ROYAL - fig5

Warning! The Power and IO Unit (PIO) contains dangerous voltages. Connections should be made only by a qualified electrician. All power input and output cables should be disconnected from the mains voltage before opening the PIO Unit.
Only the auxiliary optoisolated outputs [8] covered by a separate lid may be opened and connected by the user.
The PIO Unit of the Røros Sense C system allows additional external wired connections for many purposes.  Most common are the PWM and 0…10 V control signals for standard EC fans and ventilation units

PIO UNIT SPECIFICATION

| .Power Supply and IO Unit (PIO)

---|---
| Model names| Sense CR PIO PRO (PIO-R1)
| Power supply| Total cooker hood input power: 230 V, 50 Hz, 0.5…30 W depending on operating mode
[2]| Power output to external motor| 230 V, max 5 A.
This output is not switched, only passed through from the cooker hood input to the external motor output.
[3]| Control output to motor 1(internal)| 10 V PWM, not isolated. Motor input is PELV safe.
[4,
5]| Control output to motor 2
(external)| Two optional terminals (same control value is sent to both):
1)     10 V PWM, not isolated. Must be connected to another PELV safe system.
2)     0…10 V Analog, not isolated. Must be connected to another PELV safe system.
| Power output for LED lamps (2x)| Two output channels with 3,3 V positive control signals
[7]| Auxiliary relay outputs (3x)| Max. 230 Vac, 5 A (resistive)
[8]| Auxiliary optoisolated outputs (3x)| Max. 24 VDC, 5 mA
| Operational temperature| 0…50 °C (long-term) 0…70 °C (short-term)

Balanced ventilation + Common Exaust (BC)/
External engine + Central ventilation (EC

PRIOR TO INSTALLATION

Note. If the product shall be supplemented with a Power Control Unit (PCU) see separate section

REPLACEMENT OF SEALED DAMPER HATCH WITH DAMPER HATCH (BASIC VENTILATION)
Note Only applicable where basic ventilation takes place via the cooker hood.
Caution! The cooker hood is fitted with a sealed damper hatch.
If the cooker hood shall be used in a kitchen that does not have separate basic flow ventilation the cooker hood must be equipped with a damper hatch (basic ventilation).
Replace the damper hatch prior to installing the cooker hood, see separate instructions

ROROSHETTA SENSE ROYAL - fig6

INSTALLATION

ROROSHETTA SENSE ROYAL - fig7 ROROSHETTA SENSE
ROYAL - fig8

POWER AND IO UNIT

ROROSHETTA SENSE ROYAL - fig16

Connection Diagram PIO Unit Specifications

ELECTRICAL INSTALLATION

EC FAN

ROROSHETTA SENSE ROYAL - fig17

Connection Diagram

AC FAN

ROROSHETTA SENSE ROYAL - fig28

Connection Diagram

ROROSHETTA SENSE ROYAL - AC FAN

ADJUSTING DAMPER

Warning! Damper adjustments should be made only by a qualified professional

FORCED VENTILATION

ROROSHETTA SENSE ROYAL - fig29

2.2 Measure the Pm pressure to check that the value of the m desired forced ventilation is obtained, see section Forced ventilation, Adjustment diagram

BASIC VENTILATION

ROROSHETTA SENSE ROYAL - fig 30

2.2 Measure the Pm pressure to check that the wished basic ventilation value is obtained, see section Basic ventilation, Adjustment diagram.

FORCED VENTILATION

SIZING DIAGRAM
Real pipeline pressure
ROROSHETTA SENSE ROYAL - fig32

ADJUSTMENT DIAGRAM
Pressure in measuring point

ROROSHETTA SENSE ROYAL - fig31

(Lpw = Relative A-weighted sound power level 1pW)

BASIC VENTILATION

SIZING DIAGRAM

Real pipeline pressure

ROROSHETTA SENSE ROYAL - fig33

ADJUSTMENT DIAGRAM
Pressure in measuring point

ROROSHETTA SENSE ROYAL - fig34 (Lpw = Relative A-weighted sound power level 1pW)

SAFETY AND RECOMMENDED TOOLS

ROROSHETTA SENSE ROYAL - fig35

SAFETY
Read, understand and follow the instructions to avoid personal injury and product damage.
Warning levels
Danger indicates that an accident will occur if the instructions are not followed. The accident leads to serious personal injury or possibly death.
Warning indicates that an accident may occur if the instructions are not followed. The accident can lead to serious personal injury or possibly death.
Caution indicates that an accident may occur if the instructions are not followed. The accident can lead to personal injury.

Installation and maintenance

Electrical connection to 230 VAC with protective earth.
Cut the power to the product by the circuit breaker before installation and maintenance.
The product is supplied with cable and an earthed plug to be connected to an earthed wall socket. The wall socket must be installed by an authorized electrician.
To minimize the risk of accidents, permanent installation, replacement of cable racks or another type of connection must be carried out by an authorized electrician.
LED lights should be replaced with the original spare parts.
Please contact Customer service, see section Service and warranty.

Warning! The distance between stove and product must be 50–80 cm for an electrical stove and 70–80 cm for a gas hob.
If a higher mounting height is recommended by the gas hob manufacturer, this must be taken into account.
Note! If the product shall be supplemented with a Power Control Unit (PCU) see separate section.

Caution!
Class 3R laser is used as a component for the air quality sensor system. Service of the sensor unit should be done by Class 3R laser authorized personnel. Please contact Customer service, see section Service and warranty. In case of damage exposing the visible red laser beam, avoid direct eye exposure to the beam and do not inspect it with optical instruments.

Caution!
Different wall and ceiling materials require different types of fasteners. If necessary, supplement with plugs and replace screws with those intended for the material.
Diversion of the exhaust air shall be carried out in accordance with regulations issued by the relevant authority.

CONTENT IN DELIVERY

ROROSHETTA SENSE ROYAL - fig9

Intended for: Ø160 mm / Ø125 mm

Duct out + Recirculation (DR)

ACCESSORIES

ROROSHETTA SENSE ROYAL - fig20

Duct out + Recirculation (DR)

PRIOR TO INSTALLATION

Note. If the product shall be supplemented with a Power Control Unit (PCU) see separate section.

ROROSHETTA SENSE ROYAL - fig11

INSTALLATION

ROROSHETTA SENSE ROYAL - fig12

POWER AND IO UNIT

ROROSHETTA SENSE ROYAL - fig26

Connection Diagram PIO Unit Specifications

Balanced ventilation + Common Exhaust (BC)/
External engine + Central ventilation (EC)

PRIOR TO INSTALLATION

Note. If the product shall be supplemented with a Power Control Unit (PCU) see separate section.

REPLACEMENT OF SEALED DAMPER HATCH WITH DAMPER HATCH (BASIC VENTILATION)
Note Only applicable where basic ventilation takes place via the cooker hood.
Caution! The cooker hood is fitted with a sealed damper hatch.
If the cooker hood shall be used in a kitchen that does not have separate basic flow ventilation the cooker hood must be equipped with a damper hatch (basic ventilation). Replace the damper hatch prior to installing the cooker hood, see separate instructions.

ROROSHETTA SENSE ROYAL - fig14

INSTALLATION

ROROSHETTA SENSE ROYAL - fig15

POWER AND IO UNIT

ROROSHETTA SENSE ROYAL - fig13

Connection Diagram PIO Unit Specifications

ELECTRICAL INSTALLATION

ROROSHETTA SENSE ROYAL - fig27

EC fan
AC fan

ADJUSTING DAMPER

Forced ventilation Basic ventilation

FORCED VENTILATION

Sizing diagram Adjustment diagram

BASIC VENTILATION

Sizing diagram Adjustment diagram

SAFETY AND RECOMMENDED TOOLS

ROROSHETTA SENSE ROYAL - fig36

SAFETY
Read, understand and follow the instructions to avoid personal injury and product damage.
Warning levels
Danger indicates that an accident will occur if the instructions are not followed. The accident leads to serious personal injury or possibly death.
Warning indicates that an accident may occur if the instructions are not followed. The accident can lead to serious personal injury or possibly death.
Caution indicates that an accident may occur if the instructions are not followed. The accident can lead to personal injury.
Installation and maintenance
Electrical connection to 230 VAC with protective earth.
Cut the power to the product by the circuit breaker before installation and maintenance.
The product is supplied with a cable and an earthed plug to be connected to an earthed wall socket. The wall socket must be installed by an authorized electrician.
To minimize the risk of accidents, permanent installation, replacement of cable racks or another type of connection must be carried out by an authorized electrician.
LED lights should be replaced with the original spare parts.
Please contact Customer service, see section Service and warranty.
Warning! The distance between stove and product must be 50–80 cm for an electrical stove and 70–80 cm for a gas hob.
If a higher mounting height is recommended by the gas hob manufacturer, this must be taken into account.
Note! If the product shall be supplemented with a Power Control Unit (PCU) see separate section.
Caution!
Class 3R laser is used as a component for the air quality sensor system. Service of the sensor unit should be done by Class 3R laser authorized personnel. Please contact Customer service, see section Service and warranty. In case of damage exposing the visible red laser beam, avoid direct eye exposure to the beam and do not inspect it with optical instruments.
Caution!
Different wall and ceiling materials require different types of fasteners. If necessary, supplement with plugs and replace screws with those intended for the material. Diversion of the exhaust air shall be carried out in accordance with regulations issued by the relevant authority.

CONTENT IN DELIVERY

ROROSHETTA SENSE ROYAL - fig19

Duct out + Recirculation (DR)

ACCESSORIES

ROROSHETTA SENSE ROYAL - fig10

Duct out + Recirculation (DR)

PRIOR TO INSTALLATION

Note. If the product shall be supplemented with a Power Control Unit (PCU) see separate section.

ROROSHETTA SENSE ROYAL - fig21

INSTALLATION

ROROSHETTA SENSE ROYAL - fig22ROROSHETTA SENSE
ROYAL - fig23ROROSHETTA SENSE ROYAL - fig24ROROSHETTA
SENSE ROYAL - fig25

POWER AND IO UNIT

ROROSHETTA SENSE ROYAL - fig13

Connection Diagram PIO Unit Specifications
Balanced ventilation + Common Exaust (BC)/External engine + Central ventilation (EC)
PRIOR TO INSTALLATION

Note. If the product shall be supplemented with a Power Control Unit (PCU) see separate section.

EN REPLACEMENT OF SEALED DAMPER HATCH WITH DAMPER HATCH (BASIC VENTILATION)
Note Only applicable where basic ventilation takes place via the cooker hood.
Caution! The cooker hood is fitted with a sealed damper hatch.
If the cooker hood shall be used in a kitchen that does not have separate basic flow ventilation the cooker hood must be equipped with a damper hatch (basic ventilation).
Replace the damper hatch prior to installing the cooker hood, see separate instructions.ROROSHETTA SENSE ROYAL - fig21

INSTALLATION

ROROSHETTA SENSE ROYAL - fig22ROROSHETTA SENSE
ROYAL - fig23ROROSHETTA SENSE ROYAL - fig24ROROSHETTA
SENSE ROYAL - fig25

POWER AND IO UNIT

ROROSHETTA SENSE ROYAL - fig13

Connection Diagram PIO Unit Specifications

ELECTRICAL INSTALLATION

ROROSHETTA SENSE ROYAL - fig27

EC fan
AC fan

ADJUSTING DAMPER

Forced ventilation Basic ventilation

FORCED VENTILATION

Sizing diagram Adjustment diagram

BASIC VENTILATION

Sizing diagram Adjustment diagram
Power Control Unit (PCU)

SAFETY

Warning! The cooker hood controls the stove and/or oven only if it is equipped and correctly coupled with the optional Power Control Unit (PCU).

PAIRING THE SENSOR UNIT WITH A POWER CONTROL UNIT (PCU)

PAIRING AND TESTING

Method A: Pairing with a PCU using the App

  1. Electrically install the Power Control Unit (PCU). See separate instructions.
  2. Open the RørosHetta app.
  3. Go to the Installation Guide section.
    This section may also launch automatically during a new device installation.
    The app guides you through the PCU pairing and testing process with questions regarding kitchen, stove, and oven types for optimizing the system performance.

Method B: Pairing with a PCU manually

  1. Electrically install the Power Control Unit (PCU). See separate instructions.

  2. Hold down the OK and plus buttons simultaneously for five seconds until you hear a signal and the OK indicator on The sensor panel illuminates purple.

  3. Put back the fuses or enable the circuit breaker for the cooker and oven or connect the PCU power cord to the wall socket.
    The PCU will now pair with the sensor unit, an alarm is issued with a sound (···) and light signal (the OK indicator on the sensor panel blinking green).

  4. Test the system. See separate section.

Testing the system manually

  1. Turn on one cooker plate on maximum power.
    Note With an induction cooker use a suitable dish.

  2. Hold down the OK button for five seconds.
    The system should cut off the cooker power.

  3. Test that none of the cooker plates and oven, if connected to the PCU, are operable.
    If ok, switch off the cooker and oven.

  4. Press the OK button on the sensor unit to return the cooker power.
    The OK indicator should blink green once.

TROUBLESHOOTING

SENSOR UNIT
Press the OK button to perform a function check.

  • When the OK button blinks green once, the cooker hood and sensor unit are working properly.
  • All other colors indicate an error according to the table below.
Fault Probable cause Action
Blinks yellow once Fault in the sensor unit. Contact Customer service.
Blinks yellow twice Fault in sensor unit components or software. Contact

Customer service.
Blinks yellow three times| Incorrect installation of the sensor unit.| Contact Customer service.
Product equipped with a Power Control Unit (PCU)
Fault| Probable cause| Action
Blinks blue once| Connection problems between the sensor unit and PCU.| Disconnect and then connect the fuse. If the indicator light is still on, contact Customer service.
Blinks blue twice| Fault in PCU.| Same as above.
Blinks blue three times| PCU is overheated.| Contact Customer service.
Problem| Remedy
---|---
Faulty installation position of the sensor unit| Sensor Unit has detected that it is not installed on a level surface, pointing directly at the stove.
If mounted under the cooker hood, check that the cooker hood’s bottom surface is perfectly level.
Also, check that the sensor distance from the stove is within the limitations in section Safety.
The appliance repeatedly gives false alarms| Test the system according to a separate section.
If the product is in working order, but gives repeatedly false alarms, re-run the
“Installation Wizard” in the RørosHetta App to make sure that all kitchen and cooker-related parameters are correct.

https://vimeo.com/544722789

|
---|---
https://apps.apple.com/fi/app/roroshetta/id1588858325| https://play.google.com/store/apps/details?id=fi.safera.safera

Røros Metall AS
Stamphusveien 11, NO-7374 Røros, Norway
Tel. +47 72 40 94 00 | post@roroshetta.no Provide feedback on instructions
www.roroshetta.no

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals