Clarke OFR7 1.5 KW Oil Filled Radiator Instruction Manual
- June 5, 2024
- Clarke
Table of Contents
- OPERATION & MAINTENANCE INSTRUCTIONS
- INTRODUCTION
- ENVIRONMENTAL RECYCLING POLICY
- GUARANTEE
- GENERAL SAFETY RULES
- ELECTRICAL CONNECTIONS
- BEFORE USE
- OPERATION
- SETTING THE TEMPERATURE
- SAFETY OVERHEAT SHUT OFF
- SPECIFICATION
- MAINTENANCE
- STORAGE
- DECLARATION OF CONFORMITY – UKCA
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
OFR7 1.5 KW Oil Filled Radiator
**Instruction Manual
**
Only suitable for well-insulated areas and not designed to be the primary heat
source
1.5 KW OIL-FILLED RADIATOR
MODEL NO: OFR7/150
PART NO: 6934001
OPERATION & MAINTENANCE INSTRUCTIONS
ORIGINAL INSTRUCTIONS
DL0622 – ISS 6
INTRODUCTION
Thank you for purchasing this CLARKE 1.5 kW oil-filled radiator. Before
attempting to use this product, please read this manual thoroughly and follow
the instructions carefully. In doing so you will ensure the safety of yourself
and that of others around you, and you can look forward to your purchase
giving you long and satisfactory service.
IMPORTANT
Please read all of the safety and operating instructions carefully before
using this product. Please pay particular attention to all sections of these
instructions that display warning symbols and notices.
ENVIRONMENTAL RECYCLING POLICY
Through the purchase of this product, the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment, recycling & recovery and environmentally sound disposal of the WEEE. In effect, this means that this product must not be disposed of with general household waste. It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal facility.
GUARANTEE
This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase. Please keep your receipt which will be required as proof of purchase. This guarantee is invalid if the product is found to have been abused or tampered with in any way, or not used for the purpose for which it was intended. Faulty goods should be returned to their place of purchase, no product can be returned to us without prior permission. This guarantee does not affect your statutory rights.
THE FOLLOWING TABLE ADDRESSES THE INFORMATION REQUIREMENTS OF REG.2015/1188
Item | Symbol | Value | Unit |
---|---|---|---|
Heat output | |||
Measured seasonal space heating energy efficiency | n/a % | ||
Nominal heat output | Phnom | 2. | kW |
Minimum heat output (indicative) | P min | 0 | kW |
Maximum continuous heat output | P max | 2. | kW |
Auxiliary electricity consumption
At nominal heat output| elmax| n/a| kW
At minimum heat output| el min| n/a| kW
In standby mode| else| 0| kW
Type of heat input for electric storage local heaters only
Manual heat charge control with integrated thermostat| No
Manual heat charge control with room and/or outdoor temperature feedback| No
Electronic heat charge control with room and/or outdoor temperature feedback|
No
Fan assisted output| No
Type of heat output/room temperature control (select one)
Single stage heat output, no temperature control| No
Two or more manual stages, no temperature control| No
With mechanical thermostat temp control| Yes
With electronic temperature control| No
Electronic temperature control with day timer| No
Electronic temperature control with week timer| No
Other control options (multiple selections possible)|
Room temperature control with presence detection| No
Room temperature control with open window detection| No
Room temperature control with distance control option| No
Room temperature control with adaptive start control| No
Room temperature control with working time limitation| No
Room temperature control with black bulb sensor| No
GENERAL SAFETY RULES
- Read these instructions carefully in conjunction with the illustrations, before using the oil-filled radiator.
- Before connecting the oil-filled radiator, check that the voltage indicated on the rating plate corresponds to the mains voltage in your home/office.
- AVOID the use of an extension cable because it may lead to overheating.
- Only touch the oil-filled radiator with dry hands.
- DO NOT position the oil-filled radiator where it can be touched by children, especially the very young.
- DO NOT position the oil-filled radiator directly under a power socket.
- DO NOT use this oil-filled radiator outdoors.
- This oil-filled radiator is NOT intended for use in bathrooms, laundry areas and other similar indoor locations. NEVER locate oil filled radiator where it may fall into the bathtub or other water container.
- When using the oil-filled radiator, DO NOT place in the immediate surroundings of a shower or swimming pool.
- Position the oil-filled radiator in such a manner that the airflow toward the oil-filled radiator and away from it, is not obstructed.
- The oil-filled radiator must NOT be covered.
- Allow a safe area around the oil-filled radiator away from furniture or other objects; at least 50cm from the top and sides and front.
- DO NOT use this oil-filled radiator when it is lying on its side.
- If the oil-filled radiator is tipped over, unplug it and allow it to cool before standing it back up.
- DO NOT use the oil-filled radiator in rooms with explosive gas (e.g. petrol) or while using inflammable glue or solvent (e.g. when glueing or varnishing parquet floors, PVC etc)
- Extra caution is necessary when the oil-filled radiator is used near children or when it is left unattended.
- Keep the main cable at a safe distance from the main body of the oil-filled radiator.
- DO NOT hang anything in front of or above the oil-filled radiator.
- If overheating should occur, the built-in overheating safety device will switch off the oil-filled radiator.
- DO NOT use aerosols, flammable substances or materials sensitive to heat in the flow of hot air.
- Should the oil-filled radiator stop working, first check the fuse in the plug or fuse in the circuit breaker at the distribution board is operating, before contacting the manufacturer or its service agent or a similarly qualified person in order to avoid the hazard.
- If the supply cable or plug is damaged, it must be replaced by the manufacturer.
- Repairs that require opening of the radiator body (like oil leakage) are only to be made by the manufacturer or his service agent.
- The oil-filled radiator contains no user-serviceable parts.
- When scrapping the oil-filled radiator, follow the regulations concerning the disposal of oil.
ELECTRICAL CONNECTIONS
WARNING! Read these electrical safety instructions thoroughly before
connecting the product to the mains supply.
Before switching the product on, make sure that the voltage of your
electricity supply is the same as that indicated on the rating plate. This
product is designed to operate on 230VAC 50Hz. Connecting it to any other
power source may cause damage.
This product may be fitted with a non-rewireable plug. If it is necessary to
change the fuse in the plug, the fuse cover must be refitted. If the fuse
cover becomes lost or damaged, the plug must not be used until a suitable
replacement is obtained.
If the plug has to be changed because it is not suitable for your socket, or
due to damage, it should be cut off and a replacement fitted, following the
wiring instructions shown below. The old plug must be disposed of safely, as
insertion into the main socket could cause an electrical hazard.
WARNING! The wires in the power cable of this product are coloured in
accordance with the following code: Blue = Neutral Brown = Live Yellow and
Green = Earth
If the colours of the wires in the power cable of this product do not
correspond with the markings on the terminals of your plug, proceed as
follows.
- The wire which is coloured blue must be connected to the terminal which is marked N or coloured Black.
- The wire which is coloured brown must be connected to the terminal which is marked L or coloured Red.
- The wire which is coloured Yellow and Green must be connected to the terminal which is marked E or coloured Green.
****We strongly recommend that this machine is connected to the mains supply
via a Residual Current Device (RCD)
If in any doubt, consult a qualified electrician. DO NOT attempt any repairs
yourself.
BEFORE USE
CONNECTING THE FEET
-
Turn the oil-filled radiator upside down and insert the securing loop as shown.
-
Hook the securing loop to the wheel plate and feed the threaded end of the securing loop through the second hole as shown.
· The arms on the wheel plate should be pointing outwards. -
Fix the wheel plate in position with the wing nut supplied.
-
Fit the second wheel plate at the other end of the radiator again with the arms pointing outwards
-
Turn the oil-filled radiator the right way up and fit the wheels as shown securing them using the nuts supplied.
OPERATION
CAUTION: DO NOT OPERATE THE RADIATOR UNLESS IT IS PLACED IN AN UPRIGHT POSITION.
· Select an indoor location for the radiator away from electrical cables,
drapes and other furnishings.
· DO NOT place radiator directly beneath an electrical outlet or against the
paper board or low-density fibreboard.
-
Turn the thermostat to “0” before plugging in the radiator.
-
Plug the radiator into the main supply.
NOTE: The first time the radiator is used there may be an odour that will disappear after approximately 30 minutes of operation. -
Use the power switches to turn the radiator on.
SWITCH| SETTING
---|---
Left| Left
Right| Medium
Both| Maximum
SETTING THE TEMPERATURE
The operating temperature is selected by adjustment of the thermostat.
- The hottest setting will be when the thermostat is to “6” and the power switches are set to maximum, the coolest is when it is set to “0”.
SAFETY OVERHEAT SHUT OFF
Your oil-filled radiator is fitted with two safety devices.
The first is an anti-tilt switch which turns off the oil-filled radiator if it
falls over; simply stand the radiator up again to reset this switch.
The second is a safety overheat device which switches off the oil-filled
radiator in the event of overheating caused by any fault condition which
induces a rapid temperature rise.
In the event of the safety overheating device operating, the oil-filled
radiator will cease to function until the temperature falls below the cut-off
point. If this happens again have your oil-filled radiator serviced by an
approved service agent.
The safety device supplied must never be replaced by anyone other than an
approved service agent.
SPECIFICATION
Model Number | OFR7/150 |
---|---|
Operating Voltage and Frequency | 230 V @ 50 Hz |
Input Power | 1500 W |
Number of segments | 7 |
Class of Protection: | I |
IP Rating: | IP20 |
Dimensions (L x W x H) | 350 x 250 x 630 mm |
Weight | 9.2 Kg |
MAINTENANCE
CLEANING
The oil-filled radiator requires regular cleaning to ensure trouble-free
operation:
- DO NOT stand on or drop the heater and treat it carefully at all times.
- Always turn off and unplug the oil-filled radiator from the main supply and allow it to cool before cleaning.
- Use a damp cloth to wipe the exterior of the oil-filled radiator to remove dust and dirt.
- Ensure the oil-filled radiator is dry before plugging back into the main supply.
- DO NOT allow water to run into the interior of the oil-filled radiator as this could create a fire or electric shock hazard.
STORAGE
If the oil-filled radiator is not going to be used for long periods, for example during the summer, it should be stored in a dry place and preferably covered to prevent the accumulation of dust and dirt. Unplug the oil-filled radiator and store the mains lead in the storage recess provided. Ensure that the plug does not trail on the floor where it could be damaged.
DECLARATION OF CONFORMITY – UKCA
INTERNATIONAL
Chennai Street, Epping. Essex CM I6 4LG
DECLARATION OF CONFORMITY
This Is an important document and should be retained.
We hereby declare that this product(s) complies with the following statuary
requirement(s):
Electromagnetic Compatibility Regulations 2016
Electrical Equipment (Safety) Regulations 2016
The Restfictkm of Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012
The Eco-design for Energy Related Products and Energy Information (Amendment)
Regulations 2019
The following standards have been applied to the product(s):
EN 55014-1:2017. EN 55014-2:2015, EN 61000-3-2:2014, EN IEC 61000-3-2:2019. EN
61000-3-3:2013+A1:2019,
EN 60335.1:2012+A11:2014+A13:2017+A1:2019+A14:2019+A2:2019, EN
60335-2-30.2009•A11.2012,
EN 62233:2008, IEC 62321-3-1:2013, IEC 62321-6:2015, IEC
62321-4:2013+AMD1:2017CSV, IEC 62321-5:2013,
IEC 62321-7-1:2015, IEC 62321-7-2:2017, IEC 62321-8:2017, ISO 17075:2017, !EC
62301:2011, EN 50564:2011.
EN 60675:1995+A1:1998+A2.2008+A11:2019.
The technical documentation required to demonstrate that the product(s)
meet(s) the requirement(s) of the aforementioned legislation has been compiled
and is available for Inspection by the relevant enforcement authorities.
The UKCA mark was first applied In: 2022
Product Description: Oil Filled Electric Radiators
Model number(s): OFR7/160. OFR9190, OFR9/200, OFR13/250, 8R91200, BR131250
Serial I batch Number: N/A
Date of Issue: 07/06/2022.
Signed:
OCR7-I 50 UKCA Clint DOC 060722
Peer 1 of I
DECLARATION OF CONFORMITY – CE
INTERNATIONAL
Chennai Street, Epping. Essex CM I6 4LG
DECLARATION OF CONFORMITY
This Is an important document and should be retained.
We hereby declare that this product(s) complies with the following statuary
requirement(s):
Electromagnetic Compatibility Regulations 2016
Electrical Equipment (Safety) Regulations 2016
The Restfictkm of Use of Certain Hazardous Substances in Electrical and
Electronic Equipment Regulations 2012
The Eco-design for Energy Related Products and Energy Information (Amendment)
Regulations 2019
The following standards have been applied to the product(s):
EN 55014-1:2017. EN 55014-2:2015, EN 61000-3-2:2014, EN IEC 61000-3-2:2019. EN
61000-3-3:2013+A1:2019,
EN 60335.1:2012+A11:2014+A13:2017+A1:2019+A14:2019+A2:2019, EN
60335-2-30.2009•A11.2012,
EN 62233:2008, IEC 62321-3-1:2013, IEC 62321-6:2015, IEC
62321-4:2013+AMD1:2017CSV, IEC 62321-5:2013,
IEC 62321-7-1:2015, IEC 62321-7-2:2017, IEC 62321-8:2017, ISO 17075:2017, !EC
62301:2011, EN 50564:2011.
EN 60675:1995+A1:1998+A2.2008+A11:2019.
The technical documentation required to demonstrate that the product(s)
meet(s) the requirement(s) of the aforementioned legislation has been compiled
and is available for Inspection by the relevant enforcement authorities.
The CE mark was first applied In: 2007
Product Description: Oil Filled Electric Radiators
Model number(s): OFR7/160. OFR9190, OFR9/200, OFR13/250, 8R91200, BR131250
Serial I batch Number: N/A
Date of Issue: 07/06/2022.
Signed:
OCR7-I 50 UKCA Clint DOC 060722
A SELECTION FROM THE VAST RANGE OF
| QUALITY PRODUCTS
AIR COMPRESSORS
From DIV to industrial, Plus air tools, spray guns and accessories.
GENERATORS
Prime duty or emergency standby for business, home and leisure.
POWER WASHERS
Hot and cold, electric and engine driven – we have what you need
WELDERS
Mig, Arc, Tig and Spot. From DIV to auto/industrial.
METALWORKING
Drills, grinders and saws for DIV and professional use.
WOODWORKING
Saws, sanders, lathes, mortises and dust extraction.
HYDRAULICS
Cranes, body repair kits, and transmission jacks for all types of workshop
use.
WATER PUMP S
Submersible, electric and engine drove for DIY, agriculture and industry.
POWER TOOLS
Angle grinders, cordless drill sets, saws and sanders.
STARTERS/CHARGERS
All sizes for car and commercial use.
‘|
---|---|---
Parts Enquiries
Parts@clarkeinternational.com
Servicing & Technical Enquiries
Service@clarkeinternational.com
SALES: UK 01992 565333 or Export 00 44 (0)1992 565335
(larle NTERNATONAL eras«ca sos. es.o cs as
www.clarkeinternational.com
Parts & Service: 020 8988 7400
E-mail: Parts@clarkeinternational.com
Service@clarkeinternational.com
Read User Manual Online (PDF format)