steinel HG 2520 E Professional Heat Guns Instruction Manual
- June 5, 2024
- STEINEL
Table of Contents
Information
HG 2520 E
Instruction Manual
Translation of the original operating instructions
Please familiarise yourself with these operating instructions before using
this product because of prolonged reliability and the trouble-free operation
will only be ensured if it is handled properly.
We hope your new hot air tool will give you lasting satisfaction.
Safety warnings
Read and observe this information before using the tool. Failure to observe
the operating instructions may result in the tool becoming a source of danger.
When using electric power tools, observe the following basic safety
precautions to avoid electric shock as well as the risk of injury and fire.
Used carelessly, the tool can start an unintentional fire or injure persons.
Check the tool for any damage (mains connection lead, housing, etc.) before
putting it into operation, and do not use the tool if it is damaged.
Do not leave the tool switched on unattended.
Children should be supervised to make sure they do not play with the tool.
First time of use
A small quantity of smoke may occur when the tool is used for the first time.
This smoke is caused by binding agents released from the heater’s insulating
film during the first time of use.
To let the smoke escape quickly, the tool should be set down on its standing
surface. The area you are working in should be well ventilated when using the
tool for the first time.
Any smoke coming out of the tool is not harmful!
Take the ambient conditions into account.
Do not expose electric power tools to rain. Do not use electrical power tools
when they are damp or in a damp or wet environment. Exercise care when using
the tool in the proximity of flammable materials. Do not direct the tool at
one and the same place for a prolonged period. Do not use it in the presence
of an explosive atmosphere. Escaping heat may be conducted to flammable
materials that are hidden from direct sight.
Protect yourself from electric shock.
Avoid coming in contact with grounded objects, such as pipes, radiators,
cookers, or refrigerators.
Do not leave the tool unattended while in operation.
Store your tools in a safe place.
After use, set the tool down on its standing surface and let it cool be
fore putting it away.
When not in use, tools must be stored in a dry, locked room out of children’s
reach.
This tool may be used by children aged 8 or above and by persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge
if they are supervised or have been given instructions on how to use the tool
safely and understand the hazards involved.
Do not allow children to play with the tool.
Children are not allowed to clean or carry out maintenance work on the tool
without supervision.
Do not overload your tools.
Your work results and safety will be enhanced if you operate the tool wit hin
the specified output range.
Do not carry the tool by the power cord. Do not unplug the tool by pul ling
on the power cord. Protect the power cord from heat, oil, and sharp edges.
Always ensure that the blow-out tube (including in combination with mounted
nozzle) is never completely covered or sealed.
Damage to the heating element or motor may otherwise result.
Beware of toxic gases and fire hazards.
Toxic gases may occur when work ing on plastics, paints, varnishes, or
similar materials.
Beware of fire and ignition hazards.
For your own safety, only use ac accessories and attachments that are
specified in the operating instructions or recommended or specified by the
tool manufacturer.
Using attachments or accessories other than those recommended in the operating
instructions or cata Logue may result in personal injury.
Repairs must only be carried out by a qualified electrician.
This electric power tool complies with the relevant safety regulations.
Repairs should only be performed by a qualified electrician. Otherwise, the
user may run the risk of accidents.
Residual heat indicator
The residual heat indicator serves as a visual warning to prevent inju dry
from direct contact with the hot nozzle outlet. The residual heat indicator
also works when the tool is un plugged. The indicator starts working after
the tool has been in use for 90 seconds and keeps flashing until the
temperature at the nozzle outlet has fallen below 60 °C at room temperature.
The residual heat indicator does not show if the tool has been in operation
for less than 90 seconds.
Responsibility always rests with the user as care must be taken at all times
when handling hot air tools.
Keep these safety precautions with the tool.
For your safety
The tool is protected from overheating:
The thermal cut-out completely shuts down the tool if it is overloaded.
Tool description – Operation
Please note The distance from the object you are working on depends on the
material and intended method of working.
Always try out the airflow and temperature on a test piece first. Using the
attachable accessory nozzles (see accessories page on the cover) the flow of
hot air can be controlled with maximum precision.
Take care when changing hot nozzles! When using the hot air tool in the self-
resting position, make sure it is standing on a stable, non-slip, and clean
surface.
Switch-on procedures generate short-term voltage drops. In unfavourable grid
conditions, adverse effects can occur on other devices. With grid impedances
of less than 0.35 ohms, no disturbances are expected.
-
Operation
The tool is switched on and off at the ON/OFF switch 12 on the back of the grip handle. The joystick 10 is used for controlling temperature and airflow or fan speed. -
Setting the temperature
Temperature can be infinitely varied over a range of 50-700 °C at the joystick on the control panel with an LCD display. The actual temperature is measured at the hot air outlet nozzle and indicated on the display. The joystick 10 is used as an input button with a plus/minus function. Briefly pressing the “+/–” joystick increases or reduces the temperature setting in 10 °C steps. Keeping the joystick pressed speeds up the temperature-setting process. Once the temperature has been set, the tool takes a few seconds to reach temperature (depending on speed/airflow). The temperature setting selected is shown on the display for 3 seconds. The display then shows the current actual temperature. The “°C/°F” symbol continues to flash until the selected temperature is reached. If you want to alter the setting, simply press the joystick again to increase or reduce the temperature. After switching off, the hot air tool stays in the last setting. -
Setting airflow rate
To change the airflow rate, first press the button for airflow mode 8; the fan symbol flashes. Now use the joystick to set the air flow rate. The airflow rate setting mode automatically closes if the airflow rate setting is not changed within 5 s. Pressing the airflow button again after setting the airflow rate immediately closes the airflow rate setting mode. The airflow rate can be varied from a minimum of 150 l/min to a maximum of 500 l/min. -
Programming mode [P]
Four programmes are factory-set for the most common types of work. Press button “P” for programming mode. Number 1 is displayed for programme 1. Continuing to press the programme selection button will take you to programmes 2-4. Pressing the button again will return the tool to normal operation.
Preset programmes Programme| Temperature °C| Air l/min
---|---|---
1| 250| approx. 350
2| 350| approx. 400
3| 450| approx. 500
4| 550| approx. 400 -
Memory function [S]
The values selected for the four programmes can be changed and memorised at any time. To do this, first press the programme selection button “P” 9 until the display shows the programme you wish to change. Set the temperature and airflow rate you require. The memory symbol on the LCD flashes to indicate that the user programme selected has been changed. To record this setting in the user pro gramme selected press and hold down the programme selector button. The memory symbol continues to flash for approx. 2 s. The settings entered have been saved once the memory symbol stays on all the time. To return to normal operation, press the programme selection button until the programme symbol disappears from the display.
Temperature measurement on the workpiece
Use the STEINEL HG Scan PRO temperature scanner (Prod. No.: 007690) for measuring the temperature at the workpiece.
Heating element
The HG 2520 E hot air tool can be switched off directly after use. There is no need to let the tool cool down after the work process. This does not affect the heating element’s life.
Repair
Changing the power cord 13
****If the power cord is damaged, it can easily be changed without opening the casing.
- Important! Disconnect the tool from the power supply.
- Undo screw d and pull off cover cap a.
- Release cable grip b.
- Undo mains terminals c.
- Pull out cable e.
- Insert new cable and secure in reverse order (1. Firmly screw down mains terminals etc.).
Changing the heating element
The plugin heating element in the HG 2520 E can be changed in a matter of
seconds.
- Important! Disconnect the tool from the power supply.
- Undo guard sleeve screws ( Fig. 1 ).
- Remove guard sleeve ( Fig. 1 ).
- Undo 4 screws at the end of the hot air outlet nozzle ( Fig. 2 ).
- Detach the heating element and replace it with a new one ( Fig. 2/3 ).
- Firmly screw the heating element into place ( Fig. 3 ).
- Firmly screw guard sleeve back on ( Fig. 4 ).
LOC function
To avoid altering the chosen settings unintentionally, the HG 2520 E comes
with a Lockable Override Control Function (LOC). To find out how to set the
LOC function, please contact our Service Department on +44/1733/366700.
Tool features
1. Stainless steel outlet nozzle
2. Removable guard sleeve
3. Removable cap for mounting HG Scan PRO temperature scanner
4. Hanger
5. Residual heat indicator
6. LCD display
7. Soft coating for non-slip standing| 8. Button for airflow rate mode
9. Programme selector button and memory button
10. Joystick (for setting temperature and airflow rate)
11. Air inlet
12. ON/OFF switch
13. Replaceable mains power cord
14. Heavy-duty rubber-insulated power cord Soft grip handle for comfortable
operation
---|---
Technical Specifications
Voltage | 220-230 V, 50/60 Hz |
---|---|
Output | 2300 W max. |
Temperature | 50-700 °C, continuously variable |
Airflow rate | 150-500 l/min, continuously variable |
Air pressure | 4000 Pa |
Delivery nozzle Ø | 30mm, using Professional nozzles |
Brushless motor life | 10,000 hrs. |
Residual heat indicator | Yes |
Power cord | H07 RN-F 2X1 3.0M |
Protection class (without earth terminal) | II |
Thermal cutout | Yes |
Emission sound pressure level | ≤ 70dB (A) |
Total vibration value | ≤ 2.5 m/s²/ K = 0.08 m/s² |
Weight without power cord | 0.84 kg |
Subject to technical modifications
Applications
Here are some of the applications you can use STEINEL hot air tools for. This selection is by no means exhaustive – no doubt you can immediately think of other examples.
- Applying films in advertising and vehicle wrapping.
- Welding tarpaulins and films.
- Welding PVC floor coverings and linoleum.
- Working rigid thermoplastic materials in plastics and tank construction.
- Shaping thermoplastics.
- Drying wet surfaces.
- Activating and removing glues and hotmelt adhesives.
- Drying and heating processes of all kinds.
- Smoothing leather.
Guide for selecting the right type of welding rod for welding plastics
Material| Applications| Characteristic signs
Rigid PVC| Pipes, fittings, tiles, structural sections, technical mouldings
300 °C welding temperature| Chars when held in a flame, pungent odour;
crashing sound
Rigid PE
(HDPE) Polyethene| Tubs, baskets, canisters, insulating material, piping 300
°C welding temperature| Light yellow flame, drips continue to burn, smells of
a candle being extinguished; crashing sound
PP
Polypropylene| High-temperature drainpipes, seat buckets, packagings,
automotive parts 250 °C welding temperature| Bright flame with a blue core,
drips continue to burn, pungent odour; crashing sound
ABS| Automotive parts, equipment enclosures cases 350 °C welding temperature|
Black, fluffy smoke, sweet odour; crashing sound
Accessories
(see Fig. on page 2.)
1 | Round nozzle, 5 mm | Prod. No. 092214 |
---|---|---|
2 | Round nozzle, 10 mm | Prod. No. 092313 |
3 | Round nozzle, 5 mm, extended | Prod. No. 009076 |
4 | Flat angled nozzle, 20 x 2 mm | |
Flat angled nozzle, 20 x 2 mm, straight | Prod. No. 092115 |
Prod. No. 013240
5| Flat angled nozzle, 40 x 2 mm| Prod. No. 092016
6| Flat angled nozzle, 30 x 2 mm| Prod. No. 011925
7| Flat angled nozzle, 40 x 2 mm, perforated| Prod. No. 009083
8| Flat nozzle, 60 x 2 mm, for bitumen| Prod. No. 009090
9| Pressure roller, 50 mm| Prod. No. 093211
10| Pressure roller, 35 mm| Prod. No. 006785
11| Tarpaulin shears| Prod. No. 010423
12| Kehlfix| Prod. No. 011833
13| Weld slide| Prod. No. 093013
14| Welding nozzle| Prod. No. 075316
15| Fast welding nozzle, 3 mm| Prod. No. 010263
16| Fast welding nozzle, 4 mm| Prod. No. 010270
17| Fast welding nozzle, 5 mm| Prod. No. 010287
18| Fast welding nozzle, 3 mm, with narrow air slot| Prod. No. 009106
19| Fast welding nozzle, 4 mm, with narrow air slot| Prod. No. 011765
20| Fast welding nozzle, 5 mm, with narrow air slot| Prod. No. 011840
21| Jointing plane| Prod. No. 093112
22| Quarter-moon knife| Prod. No. 092917
23| Soldering reflector nozzle| Prod. No. 011871
24| Reflector nozzle, 20 mm| Prod. No. 011857
25| Reflector nozzle, 35 mm| Prod. No. 011864
26| Sieve reflector nozzle, 30 x 20 mm| Prod. No. 010416
27| Sieve reflector nozzle, 50 x 35 mm| Prod. No. 010409
28| Shell reflector nozzle| Prod. No. 011888
29| HG Scan PRO| Prod. No. 007690
Declaration of Conformity
(refer to page 160)
Manufacturer’s warranty
This STEINEL product has been manufactured with the utmost care, tested for
proper operation and safety and then subjected to random sample inspection.
STEINEL guarantees that it is in perfect condition and in proper working
order.
The product is guaranteed for 12 months or 10,000 hours of operation
commencing on the date of sale to the consumer. We will remedy defects caused
by material flaws or manufacturing faults. The warranty will be met by repair
or replacement of defective parts at our own discretion. This guarantee does
not cover damage to wearing parts, damage or defects caused by improper
treatment or maintenance nor does it cover breakage as a result of the product
being dropped. Further consequential damage to other objects shall be
excluded.
Claims under warranty shall only be accepted if the product is sent fully
assembled and well packed complete with sales receipt or invoice (date of
purchase and dealer’s stamp) to the appropriate Service Centre or handed into
the dealer within the first 6 months.
1 YEAR
MANUFACTURER’S
WARRANTY
EC Declaration of Conformity
A. Designation of Product
Product: Hot air gun HG 2520 E
Type designation: 3516
Mark of origin: STEINEL
Declaration of Conformity with European Community Directives
The designated product complies with the following directives and relevant
standards in the current version:
B.1. Machinery Directive 2006/42/EC including amendments
DIN EN ISO 3744:2011-02, DIN EN 60745-1:2010-01, DIN EN ISO 11203:2010-01
DIN EN ISO 4871:2009-11, DIN EN 12096:1997-09,
DIN EN 60335-1 (VOE 0700-1):2012-10; EN 60335-1:2012
DIN EN 60335-1 Ber.1 (VDE 0700-1 Ber.1):2014-04; EN 60335-1:2012/AC.2014; EN
60335-1:2012/A11:2014
DIN EN 60335-2-45 (VDE 0700-45):2012-08; EN 60335-2-45:2002+A 1 +A2:2012
DIN EN 62233 (VOE 0700-366):2008-11; EN 62233:2008
DIN EN 62233 Ber.1 (VOE 0700-366 Ber.1 ):2009-04; EN 62233 Ber.1:2008
B.2 Electromagnetic Compatibility Directive 2014/30/EU including
amendments
DIN EN 55014-1 (VDE 0875-14-1):2012-05; EN 55014-1 :2006 + A1 :2009 + A2:2011
DIN EN 61000-3-2 (VDE 0838-2):2010-03; EN 61000-3-2:2006 + A1:2009 + A2:2009
DIN EN 61000-3-11 (VDE 0838-11):2001-04; EN 61000-3-11:2000
DIN EN 55014-2 (VDE 0875-14-2):2009-06; EN 55014-2:1997 + A1:2001 + A2:2008
Requirements of category II
B.3 RoHS – Directive 2011/65/EU including amendments
B.4 WEEE – Directive 2012/19/EU including amendments
C. Retention of documents and Archive:
STEINEL GmbH, Abteilung: Zulassungen. The documents are held available for
ten years after the last marketing STEINEL GmbH, approval department.
C.1 Authorized person for the technical documentation
Klaus Wenners, Steiner GmbH, Dieselstrasse 80-84
D. Issuer and address
STEINEL GmbH, Dieselstrasse 80 – 84, 33442 Herzebrock-Clarholz/ Germany
STEINEL Vertrieb GmbH
Dieselstraße 80-84
33442 Herzebrock-Clarholz
Tel: +49/5245/448-188
www.steinel.de
Contact
www.steinel.de/contact
110059283 06/2019_A Subject to technical modification without notice.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>