VENTURE LIGHTING BF0013 LED Strip Fixture User Manual

June 5, 2024
VENTURE LIGHTING

VENTURE LIGHTING BF0013 LED Strip Fixture

VENTURE LIGHTING BF0013 LED Strip Fixture-fig1

Before You Begin

Read These Instructions Completely and Carefully

Surface Mount Installation Instructions

  • STEP 1: Disconnect power from the existing luminaire and follow proper lockout/tag out procedures before beginning installation or maintenance.

  • STEP 2: Remove the existing luminaire. Dispose of the lamp(s) and ballast(s) per local requirements.
    STEP 3: Secure the provided brackets onto the ceiling/wall with included hardware (2pcs Brackets, 2pcs Anchors, 2pcsMounting Screws). Brackets should be spaced 41-3/4” apart on center.

  • STEP 4: Screw the outlet covers to the back of the fixture housing with included screws (4pcs). (A)  Steps 5, 6 and 8 are Optional
    STEP 5: Remove the lens by gently squeezing the sides of the lens and lifting. (B)
    STEP 6: Lift the plate that holds the LED module to access the fixture wiring compartment. (B)

  • STEP 7: Connect the wiring per the Wiring Diagram to the main power. (C)
    NOTE: The polarity of the dimming connections is important to ensure the performance as desired.
    NOTE: If not using the dimming functionality, DO NOT connect the Driver Dim(+) (purple) to the Driver Dim(-) (pink). The fixture will not operate as desired.
    NOTE: If not using the dimming functionality, insulate Dim(+) (purple) and Dim(-) (pink) wires separately. Bare wires should not be exposed.

  • STEP 8: Replace the LED module plate and lens. (D)
    STEP 9: Then, clip the mounting brackets into the slots on the side of the fixture. (E)
    STEP 10: Power can now be restored to the fixture.

Suspended Mount Installation Instructions

  • STEP 1: Disconnect power from the existing luminaire and follow proper lockout/tag out procedures before beginning installation or maintenance.

  • STEP 2: Remove the existing luminaire. Dispose of the lamp(s) and ballast(s) per local requirements.

  • STEP 3: Clip the brackets into the slots on the side of the fixture. (E) Insert the V-hook into the bracket. (F)

  • STEP 4: Suspend the fixture from chain or cable (not supplied).  Steps 5, 6 and 8 are Optional

  • STEP 5: Remove the lens by gently squeezing the sides of the lens and lifting. (B)

  • STEP 6: Lift the plate that holds the LED module to access the fixture wiring compartment. (B)

  • STEP 7: Connect the wiring per the Wiring Diagram to the main power. (C)
    NOTE: The polarity of the dimming connections is important to ensure the performance as desired.
    NOTE: If not using the dimming functionality, DO NOT connect the Driver Dim+ (purple) to the Driver Dim- (pink). The fixture will not operate as desired. Insulate Dim(+) (purple) and Dim(-) (pink) wires separately.

  • STEP 8: Replace the LED module plate and lens.

  • STEP 9: Power can now be restored to the fixture.VENTURE LIGHTING BF0013 LED Strip Fixture-fig2

Wire Guard Installation

  • STEP 1: Unpack wire guard and hardware kit. See hardware list below.
  • STEP 2: Slide wire guard over fixture.
  • STEP 3: Attach plastic clips near each corner of the wire guard (4 total). Flat side of clips should face the fixture. Ensure clips are placed so screws will not puncture any internal components or wiring.
  • STEP 4: The wire guard should sit on the fixture so there is a gap between wire guard and fixture lens.
  • STEP 5: Screw in self-tapping screws through plastic clips to secure wire guard to fixture.

Hardware Kit Components

  • 1pc Wire guard
  • 4pcs Plastic clips
  • 4pcs Self-tapping screws

WARNING
Risk of fire and electric shock

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards, read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Commercial installation, service and maintenance of luminaire should be performed by a qualified licensed electrician.
  • For the installation: If you are unsure about the installation or maintenance of the luminaires, consult a qualified licensed electrician and check your local electrical code.
  • To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects.
  • Do not make or alter any open holes in an enclosure or wiring or electrical components during kit installation.

WARNING

  • Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.
  • Turn off the power when you perform any maintenance.
  • Verify that supply voltage is correct by comparing it with the luminaire label information.
  • All wiring connections should be capped with UL approved wire connectors.

CAUTION

  • Avoid direct eye exposure to the light source while it is on.
  • Account for small parts and destroy packing material, as these may be hazardous to children.
  • Risk of burn. Disconnect power and allow fixture to cool before changing bulb or handling fixture.

ABOUT COMPANY

SCAN THE QR CODE FOR MORE INFORMATION

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VENTURE LIGHTING User Manuals

Related Manuals