TECH 700 DA
User manual
Intended use
The STABILA TECH 700 DA is an electronic angle finder with a digital display
for quickly and easily measuring angles. Together with the vials, the angle
finder can also be used as a spirit level.
If you still have questions after reading
through the operating instructions, you
can obtain advice by telephone:
+49 63 46 3 09 0
1.800.869.7460 U.S. and Canada
Equipment and functions:
- Electronics module with digital display for accurately setting and measuring angles
- Vertical vial for vertical leveling
- Horizontal vial for horizontal leveling
Components of the unit
- 2 measuring surfaces
- Vials – vertical and horizontal
- Arm with 2 marking and cutting edges
- LOCK system – to fix the set angle
- Keyboard
- Display
- Battery compartment lid
Insert batteries / Battery replacement
Unscrew the battery compartment lid on the front, and insert new batteries
according to the symbol in the battery compartment.
Suitable rechargeable batteries can also be used.
LCD:
low battery charge – insert a new battery
Dispose of used batteries at suitable collection points – not with household
waste. Do not leave in the unit! Remove the batteries if you do not intend to
use the unit for some time!
Commissioning
After switching on, the version number S x.xx of the measuring program is briefly displayed. The unit is switched off by briefly pressing the “ON/OFF” button. The “OFF” confirmation appears for 1 second.
Automatic switch-off time
If not used for long periods, the electronic angle finder automatically switches off after 2 hours.
Angle finder
The angle finder displays the angle currently set between the arm and body. Angle measurements can be taken between 0° and 270°.
Spirit level
The angle finder with 2 measuring surfaces is also a fully functional spirit level for horizontal and vertical measurements to level construction elements. High-quality STABILA technology makes the vials suitable for measurements:
- in the normal position
- in the reverse position
Bevel gauge
The LOCK system can be used to fix the arm at the set angle.
Reference function
The REF button can be used to select any set angle as a 0° reference. The
angle details now displayed relate to this reference angle.
The next time the arm is rotated, only the newly set angle is displayed. The
display flashes in this setting. The REF symbol indicates this function
setting.
The original reference angle value is displayed for 2 seconds by briefly
pressing the REF button. The reference angle is deleted by:
- pressing and holding (≥ 3 sec) the REF button
- switching off
- the automatic switch-off function
Positive and negative angles when adjusting the arm:
an angle greater than a reference: positive angle less than a reference:
negative
Only the negative sign is displayed
Lighting
Repeatedly pressing the “Lighting” button switches the display lighting on, to half luminance or off.
HOLD function
The current measurement can be saved by pressing the HOLD button. The
measurement is displayed continuously. In this setting, the display flashes,
and the HOLD symbol is displayed. This function can be used in combination
with the reference function.
The saved measurement is deleted by again pressing the HOLD button or
switching the unit off.
Angle halving
The current measurement is halved by pressing the “Angle halving” button. The
measurement is displayed continuously. In this setting, the display flashes,
and the “Angle living” symbol is displayed.
The value is deleted by again pressing the “Angle halving” button or switching
the unit off.
Calibration of zero position
Technical Data
Accuracy of electronics module:|
---|---
Angle measurement:|
± 0.1°
| Accuracy of spirit Level:
in normal
position:
| o.5 mm / m = 0.029°
in reverse position:| 0.75 mm / m = 0.043°
Measuring range:| o° – 270°
Batteries :| 2 x 1.5 V alkaline, size Mignon, AA, LR6
Operating life :| 150 hours
Operating temperature range:| -io °C to +50 °C / 14°F to 122°F
Storage temperature range:| -20 °C to +65 °C / -4°F to 149°F
Protection class:| IP 54
Subject to technical modifications.
Europe/ Middle and South America
Australia/ Asia/ Africa
STABILA Messgeräte
Gustav Ullrich GmbH
P.O. Box 13 40 / D-76851 Annweiler
Landauer Str. 45 / D-76855 Annweiler
+ 49 63 46 309 – 0
info@de.stabila.com
USA/Canada
STABILA Inc.
332 Industrial Drive
South Elgin , IL 60177
800-869-7460
custservice@Stabila.com
www.stabila.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>