STABILA LD 320 laser distance measurer wasserwage Instructions

June 5, 2024
STABILA

STABILA LD 320 laser distance measurer wasserwage

ON/ OFF

Selection of operating mode= selection of measurement unit

  • Display setting 0.1 – 0.05° 0 [I)b. In IN/FT in partial displ~y mode
  • maximum accuracy of display= 1/8″

New measurement reference=zero point freely selectable as REF reference

Measured value memory = 0 holding of current value

Height of tool alert function

auto off Setting the switch off time ~Factory setting: ½Std= 7,5 Min , Optional + Ref: 2 Std

Automatic inversion of the display during the overhead measurement

Accuracy test

  •  Every time before starting work
  •  Alignment using the vial
  •  Recalibration if differences > 0.05°

Visual/ audible  alignment aid

Illumination

ON / OFF acoustic signal . Calibration

Replacing the batteries
Tip:

  • Remove the batteries if the unit
  • will not be used for a long period

Key Lock

The setting selected remains in memory after the unit is switched off

Care and maintenance

The unit should be cleaned with a soft cloth. Do not use solvents or thinners!Housing: hoseproofed sealings and dustprotected acc. to standard IP65

Guarantee terms and conditions

In addition to the statutory rights to which the purchaser is entitled and which are not limited by this guarantee, STABILA guarantees the instrument against defects and the absence of the warranted characteristics resulting from material or manufacturing defects for a period 24 months from the date of purchase. This guarantee is valid worldwide. STABILA has the right to decide at its own discretion whether the defects will be rectied by being repaired or whether the instrument will be replaced. STABILA accepts no further liability. Defects caused by improper handling (e.g. damage caused by the eects of powerful electric currents, operating the instrument with the incorrect voltage / type of current, use of unsuitable power sources) as well as modications to the instrument undertaken by the purchaser or third parties invalidate the guarantee. No liability is accepted for normal wear and tear and minor defects which do not detract from the function of the instrument. Please send your claims under the guarantee along with the completed guarantee certicate to the guarantor.

Operating instructions

We have endeavored to explain the unit’s handling and functioning in as clear and comprehensible manner as possible. If, however, you still have any unanswered questions, we should be pleased to provide advice over the telephone at any time on the following telephone number:In accordance with the WEEE regulations, STABILA provides a disposal programme for electronic products at the end of their service life. For more details, please contact:+49 / 6346 / 309-0

Technical Data

  • O+90°:0,5 mm/m = 0,029°
  • 1.890:0,5 mm/m = 0,029
  • Spirit level:2xAA, Mignon Alkaline, LR 6
  • In normal position:about 150 hours
  • Operating temperature range: -10 °C to +50°C (14 F to 122°F)
  • Storage temperature range: 20 °C to +65°C (-4°F to 149°F))
  • Overhead measurement:Subject to technical modifications.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

STABILA User Manuals

Related Manuals