Gude RFP 18-0 Rain Water Tank Pump Instruction Manual
- June 5, 2024
- Gude
Table of Contents
- Gude RFP 18-0 Rain Water Tank Pump
- DELIVERED ITEMS
- Connection
- Starting-up the device
- Operation
- engine protection
- Cleaning/Maintenance
- Technical Data
- Specified Conditions of Use
- Symbols
- Safety Instructions
- Battery
- Requirements for operating staff
- Maintenance
- Guarantee
- Service
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Gude RFP 18-0 Rain Water Tank Pump
DELIVERED ITEMS
Connection
Starting-up the device
Operation
engine protection
Cleaning/Maintenance
Technical Data
Rainwater tank pump | RFP 18-0 |
---|---|
Art. No | 58567 |
Voltage | 18 V |
Safety class | III |
Degree of protection | IP X8 |
Max. delivered quantity | 2000 l/h |
Max. head of delivery | 7 m |
Max. suction | 0,5 mm |
Max. Water temperature | 35 °C |
Connection | male 3/4 “ |
Cable length | 3 m |
Recommended battery types
| 58541
58542
58543
58544
Recommended charger| 58547
58548
Weight| 3,4 kg
Dimensions L x W x H| 200 x 170 x 260
Read and understand the operating instructions before using the appliance. Familiarise with the control elements and how to use the appliance properly. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties. The operator is responsible for accidents or risks to third parties. In case of any doubts about connection and operati-on refer please to our customer center.
Specified Conditions of Use
The pump is solely used for drainage and for pumping into and out of
containers in the house, garden, farm and agriculture and only for water.
Respecting technical data and safety precautions.
Do not use this product in any other way as stated for normal use. Not
observing general regulations in force and instructions from this manual does
not make the manufacturer liable for damages.
Do not use the pump at outside temperatures over 40 °C or under 0 °C.
- The pump is not suited for long-run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is curtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
- Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
- Do not use the pump for drinking water.
- The pump must not be used to pump wastewater.
- The pump must not be connected to the existing water-supply network as a pressure-boosting device.
- Never use the pump as a pool circulation pump.
Symbols
- WARNING/CAUTION!
- WARNING – Read the operating instructions to reduce the risk of injury.
- Remove the battery pack before starting any work on the appliance.
- Wear goggles.
- Staying in the transportation medium prohibited
- Warning against dangerous voltage
- Class III tool.
- Voltage
- Any damaged or disposed of electric or electronic devices must be delivered to appropriate collection centers.
- CE marking
Battery
- Protect the battery against heat and fire.
- Protect the battery against water and moisture.
- Protect the battery against temperatures above 40°C.
- Class II tool.
- Do not throw the batteries in household waste.
Deliver the batteries to a collection center of old batteries where they will be recycled in an environmentally friendly way.
Safety Instructions
- Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid!
- This appliance is not intended for use by persons (including children) with limited physical, sensory, or mental capabilities or insufficient experience and/or knowledge unless they are supervised by a person who is responsible for their safety or has been instructed by them in the safe use of the appliance.
- Children should be supervised in order to ensure that they do not play with the tool. Always keep children and unauthorized persons out of reach of the appliance.
- Remove battery before submerging.
- Remove battery after decommissioning, when remedying faults, and before maintenance.
- If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).
- The temperature of the drained liquid must not exceed +35 °C.
- The pump must not in any case run without fillings.
- Never operate the pump when it is left unsupervised in order to prevent damage caused by any possible malfunctions. In principle, you must always remove the battery when the pump is not in use.
- If the pump is used in ponds, wells, etc., and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed.
- The user is responsible to third parties if the pump (dum-ping stations, etc.) is used.
- Protect the feeder cable from excessive temperatures, oil, and sharp edges.
- To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself.
Battery
Risk of fire! Risk of explosion!
Never use damaged, defective, or deformed accumulators. Never open or damage the accumulator or let it fall on the ground. Never charge the battery in an environment with acids and easily flammable materials. Protect the battery against heat and fire. Battery to be used at ambient temperatures between 10°C and +40°C only. Never put the battery on heaters and do not expose it to strong sunlight for a long time. After being subject to heavy load, let the battery cool down first. Short circuit – do not bridge the accumulator contacts with metal parts. The accumulator must be packaged (plastic bag, box) or accumulator contacts must be sealed up for accumulator disposal, transport, or storage.
The Güde charger is to be used only to charge the battery. There can be a
malfunction or fire if different chargers are used.
Vapors may leak out in case of unauthorized use or when using a damaged
accumulator. Bring fresh air and seek medical advice if experiencing
difficulties. Vapors may irritate the respiratory system.
Working Instructions
Accumulators are supplied partially charged and must therefore be fully
charged before being used for the first time.
- Charge the accumulator when the appliance is running slowly or stops.
- A li-ion battery may be charged at any time without any shortening of its life. Charging process interruption will not damage the accumulator.
- A li-ion battery is protected by the Electronic Cell Protection against deep discharge.
- A significantly shorter operating time of a charged battery means the battery life is over and the battery must be replaced.
Dispose of the batteries in an environmentally friendly manner
Li-ion batteries are subject to the special disposal obligation. Have any
defective batteries been disposed of by a specialized shop? The battery must
be taken out before the appliance is scrapped. Damaged batteries may harm the
environment and your health if toxic vapors or liquids leak out of such
batteries. Therefore, never send a defective battery by post, etc. Please
contact your local recycling center. Dispose of the batteries when discharged.
We recommend applying adhesive tape on the poles to protect them against short
circuits. Never open the battery.
Requirements for operating staff
The operating staff must carefully read the Operating Instructions before using the appliance.
Qualification:
Apart from the detailed instructions by a professional, no special
qualification is necessary for appliance use.
Minimum age:
Persons over 16 years of age can only work on the appliance. An exception
includes youngsters trained in order to reach knowledge under the supervision
of the trainer during occupational education.
Training:
Using the appliance only requires corresponding training by a professional or
the Operating Instructions. No special training is necessary.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified
medical attendance as quickly as possible. Protect the injured person from
further harm and calm them down. If you seek help, state the following pieces
of information: 1. Accident site, 2. Accident type, 3. A number of injured
persons, 4. Injury type(s)
Maintenance
Remove the battery pack before starting any work on the appliance.
Before using the appliance, perform a visual inspection at all times to make
sure the power cord and the plug, in particular, are not damaged on the
charger. The appliance must not be used if damaged or safety equipment is
defective. Replace any worn-out and damaged parts. If the supply cord of this
power tool is damaged, it cannot be replaced, and the power tool shall be
scrapped. Repairs and works specified in these Instructions may only be
performed by qualified authorized staff. Use only original accessories and
original spare parts. Only a regularly maintained and treated appliance can
serve as a satisfactory aid. Insufficient maintenance and care can lead to
unforeseen accidents and injuries. To ensure the long service life of the pump
seal we recommend rinsing the pump with clean water at regular intervals.
Caution! Depending on the design, water that is left standing for a longer
period of time may cause corrosion in the pump housing! (Brown coloration) For
winter storage, ensure that there is no water in the device. Otherwise, frost
exposure may cause irreparable damage to the device. The pump must be stored
in a completely empty and frost-proof state. You can reduce the chance of the
mechanical seal sticking by flushing out the pump with suitable oil (e.g.
vegetable oil).
If necessary, a list of spare parts can be found at
www.guede.com.
Guarantee
The warranty period of 12 months applies to commercial use and 24 months applies to private use and commences on the day of purchase of the device. The guarantee solely covers inadequacies caused by material defects or manufacturing defects. An original payment voucher with the date of the sale needs to be submitted for any claim in the guarantee period. The guarantee does not cover any unauthorized use such as appliance overloading, use of violence, or damage as a result of any unauthorized interference or caused by foreign items. Failing to follow the operating and assembly instructions and common wear are also not included in the guarantee.
GÜDE cannot be held responsible for damages incurred as a consequence of unqualified installation or unskilled handling of the pump. The device has to be checked on a regular basis to ensure perfect functioning. Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the below-mentioned cases: Unprofessional repairs executed by unauthorized service centers;
- Use in conflict with the designed purpose, or failure to observe the use as designed;
- Pump overload with a continuous run;
- Damage as a result of icing or any other fault caused by climatic influences;
Identical regulations apply for accessory parts. To prevent damage (such as flooded rooms, etc.) as a result of faulty pump operation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).
Important information for the customer
Please be sure to know that returning the product in or after the warranty
period must be made in the original packaging.
Service
Do you have any technical questions? Any claim? Do you need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able to help you. In order to identify your device in case of claim we need the serial No., product No. and year of production. All this data can be found on the type label.
- Tel: +49 (0) 79 04 / 700-360
- Fax: +49 (0) 79 04 / 700-51999
- E-Mail: support@ts.guede.com.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>