beurer IL 35 Infrared Lamp Instruction Manual

June 5, 2024
Beurer

IL 35

Infrared lamp
Instruction for use

About the infrared lamp

Dear valued customer,
Thank you for choosing one of our products. Our name stands for high-quality, thoroughly tested products for applications in the areas of heat, weight, blood pressure, body temperature, pulse, gentle therapy, massage, and air.
With kind regards
Your Beurer team

Application

This infrared lamp is only intended for radiating the human body.
Infrared radiation causes warmth to be transported to the human body. The blood supply in the radiated skin is increased and the metabolic turnover in the field of temperature is enhanced. The mode of action of the infrared light encourages the body to heal; healing processes are thus assisted in a specific area. Infrared light can be used as a parallel treatment for diseases of the ear, nose, and throat and to assist in facial and beauty care, especially in the case of impure skin. However, first, ask your family doctor whether the application in the individual case is advisable from a medical standpoint.

Included in delivery: Infrared lamp
Protective eyewear
These operating instructions

Note: Warranty restriction
The infrared bulb included – as with all light sources – is not subject to the warranty.

Signs and symbols

The following symbols appear in these instructions or on the device.

**| Observe the instructions
Read the instructions before starting work and/or operating devices or machines| **
| Protect from moisture
---|---|---|---
**| Protection class II device
The device is double-protected
and thus corresponds to the protection class 2| **
| Product information
Note on important information
**| Caution: hot surface| **| Manufacturer
**| Warning
Warning instruction indicating risk of injury or damage to health| **
| Disposal in accordance with the Waste
Electrical and Electronic Equipment EC
Directive – WEEE
**| Important
Safety note indicating possible
damage to the device/accessory| | Distance between infrared heat lamp and irradiated body part
---|---|---|---
| Serial number| | Separate the packaging elements and
dispose of them in accordance with local regulations.
**
| CE labelling
This product satisfies the requirements of the applicable
European and national directives.| | Marking to identify the packaging material.
A = Material code,
B = Material number:
1-7 = Plastics, 20-22 =
Paper and cardboard
| Permissible operating temperature, humidity, and ambient pressure| | Permissible storage and transport temperature, humidity, and ambient
pressure

Notes

Please read these instructions for use carefully and keep them for later use, be sure to make them accessible to other users and observe the information they contain.

Safety notes
Warning

  • This infrared lamp is only intended for radiating the human body.

  • Always use the protective eyewear supplied during usage.

  • Before use, ensure that all packaging materials are removed and that there is no visible damage to the
    unit or accessories. When in doubt, do not use the unit and contact your dealer or the customer service address provided.

  • Always ensure that the appliance is on a secure and even surface.

  • The lamp housing and the infrared lamp become very hot during operation. There is a risk of burning if these are touched. Always let the lamp cool down first before touching it.

  • Inflammable objects must be kept at a distance of at least 1.0 m from the infrared lamp. Do not hang the appliance on the wall or from the ceiling.

  • Connect the unit only to the mains voltage listed on the type plate.

  • Do not dip the unit into water and do not use it in wet rooms.

  • This device is not intended for use by persons (including children) with restricted physical, sensory, or mental capabilities and/or by persons lacking the required understanding of the equipment and how it is used unless they are supervised by a person who is responsible for their safety or they are given instructions on how to use the device.

  • Do not use it on babies and small children.

  • Children should be supervised to ensure that they do not use the device as a toy.

  • This device is not intended for use on changing units, cots, or similar.

  • Cleaning and user maintenance must not be performed by children unless supervised.

  • Do not use it on persons sensitive to heat. The sensitivity to heat can be reduced or increased in the following cases:
    ― diabetic patients
    ― persons with sleepiness, dementia, or difficulties concentrating
    ― persons with illness-related skin changes or persons with scarred skin areas in the application area
    ― persons with allergies
    ― children and older persons
    ― after consuming medications or alcohol.

  • Do not operate the device if you are wearing an implant, particularly if it is located in the area of the body to be treated. If you have any doubts, consult your doctor.

  • If you are pregnant, do not operate the device near your abdomen, in order to prevent this area from overheating. If you have any doubts, consult our doctor.

  • In case of acutely inflammatory processes, radiation should only be carried out after consulting a doctor.

  • Always limit the period of use and check the reaction of the skin.

  • Medications, cosmetics, or food can lead to an over-sensitive or allergic reaction of the skin under certain conditions. Radiation must be ended immediately in this case.

  • An appropriate distance between the infrared lamp and the desired treatment area must be maintained during treatment so that no skin irritation, such as tingling, itching, burning, or too high heat sensitivity occurs. Stop the treatment if this occurs. Alternatively, increase the radiation distance and/or reduce the radiation duration.

  • This device is not intended for radiation from above.

  • The minimum distances described in these instructions for use must be adhered to.

  • Never fall asleep during radiation!

  • Prolonged use can cause burns to the skin.

  • Do not touch the infrared lamp or unscrew it when it is connected to the mains.

  • Children do not understand the risks associated with electrical appliances. Make sure the appliance is not used by children without appropriate supervision.

  • The appliance may be used only under supervision.

  • Keep children away from packaging materials (risk of suffocation).

  • Do not cover up or pack away the unit while it is warm.

  • Always remove the mains plug and let the unit cool off before you touch it.

  • Do not touch the unit with wet hands while it is plugged in; do not allow any water to be sprayed onto the unit. The unit must be operated only when it is completely dry.

  • Protect the unit from strong impacts.

  • Do not pull the mains plug from the socket by the cord.

  • In the event of a defect or malfunction, switch the device off immediately and disconnect it from the power supply.

  • If the power cord of the device is damaged, it must be replaced by the manufacturer or an authorized customer service technician in order to avoid hazards.

  • Disconnection from the mains supply is only guaranteed if the mains plug has been removed from the socket.

  • There is a risk of strangulation for babies and children who become trapped in the mains cable.

General notes
Important

  • The product is not suitable for lighting rooms in private homes.
  • This unit is not intended for commercial or clinical use, but only for individual, private household use!
  • If you have health concerns of any kind, contact your general practitioner!
  • Before you use the unit for the first time, remove all packaging materials.
  • Lighting is excluded from the warranty.

Repairs
Important

  • Do not open the device. Please do not attempt to repair the unit yourself. This could result in serious injuries. Failure to observe this regulation shall void the warranty.
  • If you need to have the unit repaired, contact customer service or an authorized dealer.

Unit description

  1. Light source
  2. Lamp shade
  3. Base
  4. On/Off button + timer button
  5. LED timer indication
  6. First LED = readiness indicator/standby

Initial use

Setup
Remove the unit from the packaging. Remove all packaging material before using the appliance. Before use, check whether the infrared lamp is properly screwed in. Place the device on flat surfaces. The appliance has an adjustable lampshade. Set the angle of the fluorescent screen in accordance with your individual requirements.
Mains connection
Connect the unit only to the mains voltage listed on the type plate.

Note :

  • Ensure that there is a socket near the place where the lamp will stand.
  • Lay the mains cable in such a way that no one can trip over it.

Replacing the fuse (UK plug only)
If the fuse needs replacing, please observe the following:

  • Remove the mains plug.
  • Lift out the fuse holder from the inside of the main plug using a flat screwdriver.
  • Pull out the fuse from the fuse holder and replace it with a new fuse type: 3A (breaking capacity 6 kA at 240 V) in accordance with BS-1362 / SS167.
  • Press the fuse holder containing the new fuse into the plug slot.
  • Plug the mains plug into the socket and test to see if it works.

Operation

1| Switching on the lamp
► To connect to the mains, fully insert the plug into the socket. Once inserted, the „5 min” LED will flash. This is the readiness indicator (standby). Press the On/Off button (4) once to switch on the lamp.
---|---
2| Enjoying the light
The recommended duration of treatment is maximum of 15 minutes and should be limited to a maximum of two treatments a day. We recommend selecting a shorter radiation period to start with. However, the skin of some people may show an over-sensitive (e.g. with extreme redness, blistering, itching, heavy sweating) or allergic reaction to heat radiation, even when the lamp is used correctly. If symptoms are not relieved after 6 to 8 applications, stop using the device and consult your doctor.
3| LED display/timer
The IL 35 infrared lamp indicates your current treatment The treatment time can be set at the following 3 levels. To scroll through the timer, hold down the On/Off button The levels are as follows:| time with the aid of 3 LEDs.
(4) until the required timer level lights up.
time has elapsed. To switch off the lamp the,5 min” LED is flashing, the other LEDs
Treatment time| Number of lit LEDs
5 minutes| 1
10 minutes| 2
15 minutes| 3
The lamp switches off automatically once the set treatment manually, repeatedly press the On/Off button (4) until only are off and the lamp goes out.
4| Important instructions
The distance between the infrared lamp and the radiated part of the body should not be less than the following: at least 32 in (80 cm).
Always use the protective eyewear supplied during usage. The protective eyewear corresponds to the requirements of EN 171:2002 and serves to protect the eyes.
CAUTION: Never look directly into the infrared light without protective eyewear. Basically,
examine the radiated section of the body regularly. Discontinue radiation immediately if any signs of an over-sensitive or allergic reaction appear and consult a physician.
5| Switching off the lamp
CAUTION!
The lamp is hot after being used. Let the lamp cool off first long enough before you put it away and/
or pack it up!
Please note that the mains cable must not be wound around the infrared lamp either for storage or
when in use.
Disconnect the mains plug from the socket to fully switch off the device.
---|---

Changing the infrared lamp

The device must be switched off and allowed to cool and the mains plug pulled out before cleaning and changing the infrared heat lamp.

Please note that only infrared lamps of the original type may be used as replacements.

Replacement infrared lamp (type): Specifications: Item number.
Infrared PAR 38 (150 W) 230V – 50 Hz 617.

Warning

  • Do not touch the infrared lamp or unscrew it when it is connected to the mains.
  • Unplug the device, to avoid the risk of electrocution.
  • In the interest of environmental protection, do not dispose of the device in household waste.

Cleaning and care of the unit

The unit should be cleaned occasionally.

Important
To avoid odors caused by fluff and dust, we recommend regularly cleaning the device as follows:

  • The device must be switched off and allowed to cool and the mains plug pulled out before cleaning and changing the infrared heat lamp.
  • Ensure that no water penetrates inside the unit!
  • Do not wash the unit in a washing machine! Clean using a damp cloth, to which you can apply a little detergent if necessary.
  • Do not use abrasive detergents and never immerse the unit in water. Do not touch the unit with wet hands while it is plugged in; do not allow any water to be sprayed onto the unit.
  • The unit must be operated only when it is completely dry.

Disposal

**** For environmental reasons, do not dispose of the device in the household waste at the end of its useful life. Dispose of the unit at a suitable local collection or recycling point. Dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the local authorities responsible for waste disposal.

Technical specifications

Mains connection 220-230 V- / 50-60 Hz
Power consumption 150 W
Max. radiation intensity 550 W/m2at distance of 80 cm
Dimensions (W x H x D) 145 x 220 x 175 mm
Weight approx. 800 g
Operating conditions Temperature: +5°C to +35°C; Relative humidity: 15%-93%

Ambient pressure: 700 hPa to 1060 hPa
Storage and transport| Temperature: -25°C to +70°C; Relative humidity: s93% Ambient pressure: 700 hPa to 1060 hPa
Expected operating life of the device| 7 years

The serial number is located on the device or in the battery compartment.
Subject to technical modifications. This device meets the requirements of the European Medical Devices Directive 93/42/EEC with amendments as well as the German Medical Devices Act.

Warranty/service

Further information on the guarantee and guarantee conditions can be found in the guarantee leaflet supplied.

Subject to errors and changes
**** Beurer GmbH • Söflinger Str. 218 • 89077 Ulm, Germany • www.beurer.com
www.beurer-healthguide.com www.beurer- gesundheitsratgeber.com

07.701.083_IL35_2022-05-03_02_IM1_BEU

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Beurer User Manuals

Related Manuals