Dear Customer, Thank you for purchasing the ZEB-MLS750 UPS. Please read the user manual carefully before usage & save it for future reference.

Important Safety Instructions

  • The voltages inside UPS may be hazardous. Do not attempt to disassemble the unit. The unit contains no user-serviceable parts. Only factory service personnel may perform repairs.

  • Internal battery voltage is 12Vdc. sealed, lead-acid, 6 cells battery.

  • Connection to any other type of socket other than a two-pole, three-wire grounded socket may result in shock hazards as well as violating local electrical codes.

  • In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS. Do not allow liquids or any external objects to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.

  • This unit is designed for installation in a controlled environment (temperature controlled, indoor area free of conductive contaminants). Avoid installing the UPS in locations where there is static or flowing water or excessive humidity.

  • Do not plug the UPS input into its own output.

  • Do not attach a power strip or surge Suppressor to the UPS.

  • Do not connect non-computer-related items, such as medical equipment, _life-support equipment, microwave ovens, or vacuum cleaners to UPS.

  • To reduce the risk of overheating the UPS, do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat-emitting appliances such as air heaters or furnaces.

  • Unplug the UPS prior to cleaning and do not use liquid or spray detergent.

  • Do not dispose the batteries into fire as they may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.

  • A battery can present a risk of electrical shock and a high short circuit current. The following precautions should be observed when working on batteries:
    a) Remove watches, rings, or other metal objects from the hands.
    b) Use tools with insulated handles.
    c) Wear rubber gloves and boots.
    d) Do not lay tools or metal parts on top of batteries.

  • Disconnect the charging source prior to connecting or disconnecting battery terminals.

  • Servicing of battery should be performed or supervised by technical and authorized personnel only.

  • When replacing the battery, replace it with the same type of sealed lead-acid battery. The maximum ambient temperature rating is 40°C.

UPS Installation Procedure

  • Your new UPS may be used immediately; however, recharging the battery for at least 8 hours (no load) is recommended to ensure that the battery’s maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the on and off position.
  • With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device (Zip drive, Jazz drive, Tape drive, etc.) into the battery power supplied outlets. DO NOT plug laser printer, copier, space heater, vacuum, paper shredder, or another large electrical device into the battery power supplied outlets. The power demands of these devices will overload and possibly damage the unit.
  • Plug the UPS into a 2 pole, 3 wire grounded socket (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not. service equipment with large electrical demands (e.g. air conditioner, refrigerator. copier, etc. Avoid using extension cords.
  • Press the power switch to turn the unit ON. The power on_ the indicator light will illuminate and the unit will “beep”.
  • If an overload is detected, an audible alarm will sound and the unit will emit a beep once every 0.5 seconds. To correct this turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds and then turn the UPS on.
  • To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times.
  • To store your UPS for an extended period, cover it and store it with the battery fully charged. Recharge the battery every three months to ensure battery life.

Product Description

ZEBRONICS ZEB-MLS750 Uninterruptible Power Supply -
fig

Front Panel

  1. Power Switch

  2. LED Indicator
    AC Mode: Green LED Glow
    Battery Mode_: Green LED Blinks
    Back Panel:

  3. AC input

  4. Output Sockets

Power On/Off (AC mode)
To turn on the UPS unit, press the power switch lightly. To turn off the UPS unit, press the power switch again Power On/Off (Battery mode)
To start the UPS when AC utility power is not available, simply press the power switch.

LED Indication and Alarm

Features

  • India’s first micro load UPS. Specially made for security and _ surveillance applications.
  • ZEB Micro Load Sense — system, Microprocessor based output load sensing feature, to sense micro power consumption devices.
  • Advanced 3 Tier battery management system, prolongs battery life by more than 30%.
  • Backup up to 3h* for Micro power consumption devices
  • Line interactive UPS
  • Auto restart while AC is recovering
  • Automatic Voltage Regulation (AVR)
  • Wide Input Range
  • Microprocessor Based
  • Generator Compatible

*(Under testing conditions with 1 DVR without HDD and 2 cameras without IR enabled)

Specification

Capacity (VA/W) 600VA/360W
Input Nominal voltage 220-240 VAC
Voltage range 140-290 VAC
Frequency 50 Hz
Plug type 3 Pin plug
Output Voltage range 230VAC±10% (AC mode)
Voltage range 230VAC±10% (Batt. mode)
Frequency range 50Hz±10/0 (Batt. mode)
Transfer time Typical 4-8ms
Waveform Simulated Sine Wave
No. of output sockets 3
Protections Overload, Short Circuit, Over Discharge &

Over Charge
Battery| Battery type| 12V 7Ah x 1 no
Charging current| 1A
Recharge time| 4-6 h to charge 90%
(after complete discharge)
Indicators| No. of LEDs| 1 LED
AC mode| Green lighting
Battery mode| Green flashing
Alarm| Battery mode| No beep till reach low voltage level
Low battery| Beeping every Second
Overload| Beeping every 0.5 seconds
Fault| Continuous beeping
Physical details| Dimension| 101 x 279 x 143 mm (W x D x H)
Net. weight| 4.2 kg
Package dimension| 328 x 144 x 220 mm (W x D x H)
Environmental factors| Operational temperature| 0-40°C
Noise level| < 40dB

Troubleshooting

Problem Possible Cause Solution

No LED Indicator on
the front panel| Battery weak| Charge battery up to 8 hours
Battery defect| Replace with the same of battery
The power switch is not pressed| Press the power switch again
Alarm buzzer beeps
continuously when AC supply is normal| Overload of the UPS| Verify that the load matches the UPS
capability specified
in the specs
When power fails, backup time is shortened| Overload of the UPS| Remove some non-critical load
The battery voltage is too low| Charge battery 8 hours or more
Battery defect due to high-temperature operation environment, or improper operation to battery| Replace with the same type of battery
Green LED is flashing| The power cord is loose| Reconnect the power cord properly

If any abnormal situations occur that are not listed above, please call the service person immediately.