SEALEY CD2005TT.V2 2000w Convector Heater with Turbo Timer & Thermostat Instructions
- June 5, 2024
- SEALEY
Table of Contents
2000W CONVECTOR HEATER WITH TURBO,
TIMER & THERMOSTAT
MODEL NO: CD2005TT.V2
Instructions
Thank you for purchasing a Sealey product. Manufactured to a high standard,
this product will, if used according to these instructions, and properly
maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR
THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR
FUTURE USE.
Refer to the instruction manual| Do not cover| Indoor use only
SAFETY
1.1. ELECTRICAL SAFETY
WARNING! It is the user’s responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe
before use. Inspect power supply leads, plugs, and all electrical connections
for wear and damage. Sealey recommends that an RCD (Residual Current Device)
is used with all electrical products. You may obtain an RCD by contacting your
local Sealey stockist.
If the heater is used in the course of business duties, it must be maintained
in a safe condition and routinely PAT (Portable Appliance Test) tested.
1.1.1. ELECTRICAL SAFETY INFORMATION It is important that the following
information is read and understood.
Ensure that the insulation on all cables and on the appliance is safe before
connecting it to the power supply.
Regularly inspect power supply cables and plugs for wear or damage and check
all connections to ensure that they are secure.
IMPORTANT: Ensure that the voltage rating on the appliance suits the
power supply to be used and that the plug is fitted with the correct fuse –
see fuse rating in these instructions.
x DO NOT pull or carry the appliance by the power cable.
x DO NOT pull the plug from the socket by the cable.
x DO NOT use worn or damaged cables, plugs, or connectors. Ensure that any
faulty item is repaired or replaced immediately by a qualified electrician.
1.1.2. This product is fitted with a BS1363/A 13 Amp 3 pin plug.
√ If the cable or plug is damaged during use, switch the electricity supply
off and remove it from use.
√ Ensure that repairs are carried out by a qualified electrician.
√ Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt
contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
√ Ensure that the cable outer sheath extends inside the cable restraint and
that the restraint is tight.
√ Sealey recommends that repairs are carried out by a qualified electrician.
1.2. GENERAL SAFETY
WARNING! Disconnect the heater from the main power supply before carrying
out any servicing or maintenance.
√ Disconnect the heater from the power supply before handling or cleaning.
√ Maintain the heater in good order and clean condition for best and safest
performance.
√ Replace or repair damaged parts. Use genuine parts only. Unauthorized parts
may be dangerous and will invalidate the warranty.
√ Ensure there is adequate lighting and keep the immediate area in front of
the outlet grille clear.
√ Only use the heater standing on its feet in the upright position.
x DO NOT allow any untrained persons to use the heater. Ensure they are
familiar with the controls and hazards of the heater.
x DO NOT let power lead hang over an edge (i.e. table), touch a hot surface,
lie in heater hot air flow, or run under a carpet.
x DO NOT touch the outlet grille (top) of the heater during and immediately
after use as it will be hot.
x DO NOT place the heater near items that may be damaged by heat.
x DO NOT place the heater too close to yourself or any object, allow the air
to circulate freely.
x DO NOT use the heater for any purpose other than for which it is designed.
x DO NOT use the heater on very deep pile carpets.
x DO NOT use the heater outdoors. These heaters are designed for indoor use
only.
x DO NOT use the heater if the power cord, plug, or the heater is damaged, or
if the heater has become wet.
x DO NOT use in bathroom, shower room, or in any wet or damp environments or
where there is high condensation.
x DO NOT operate the heater when you are tired or under the influence of
alcohol, drugs, or intoxicating medication.
x DO NOT allow the heater to get wet as this may result in an electric shock
and personal injury.
x DO NOT insert or allow objects to enter any openings of the heater as this
may cause an electric shock, fire, or damage to the heater.
x DO NOT use the heater where there are flammable liquids, solids, or gases
such as petrol, solvents, aerosols, etc, or where heat-sensitive materials may
be stored.
x DO NOT place the heater immediately below any electrical outlet.
x DO NOT cover heater when in use and do not obstruct the air inlet and outlet
grille (i.e. clothing, curtain, furniture, bedding, etc).
√ Allow the unit to cool before storage. When not in use, disconnect from the
mains power supply and store in a safe, cool, dry, childproof area.
NOTE: Children of less than 3 years should be kept away unless
continuously supervised.
Children aged from 3 years and less than 8 years shall only switch on/off the
appliance provided that it has been placed or installed in its intended normal
operating position and they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children aged from 3 years and less than 8 years shall not plug in,
regulate and clean the appliance or perform user maintenance.
INTRODUCTION
The electric convector heater features a built-in turbo fan for accelerated heating. Three heat settings of 750/1250/2000W for gradual control of heating elements. Rotary controlled room thermostat maintains the ambient temperature at a preset level. Features a 24-hour timer allowing the user to program the time and duration the heater is operated. Slimline sturdy construction and a high-quality finish make this unit suitable for home, light industrial, and office environments. Supplied with a 3-pin plug.
SPECIFICATION
Model No: ………………………………………………..CD2005TT.V2
Power Settings: ……………………………………. 750/1250/2000W
Supply: …………………………………………………………………230V
Size (WxDxH):……………………………………595 x 200x 420mm
ASSEMBLY
4.1. MOUNTING THE FEET (fig.1.)
4.1.1. Turn the heater upside down and support it securely. Take one of the
feet and place it onto the underside of the heater in the position indicated
in (fig.1).
4.1.2. When the foot is positioned correctly 2 holes in the foot will line up
with the holes in the underside of the heater.
4.1.3. Fasten each foot down with the self-tapping screws provided.
OPERATION
5.1. OPERATING THE HEATER (See fig.2)
5.1.1. Place the heater in a suitable position in the area you require heat.
5.1.2. Allow a minimum of 500mm between the heater and adjacent objects such
as furniture etc.
5.1.3. Plug the heater into the main supply.
5.1.4. Turn the thermostat knob (fig.2.C) to a high setting.
5.2. SELECTING THE HEAT OUTPUT
5.2.1. Choose the required heat output by selecting the appropriate switch
which will light up when pressed.
Low setting
Medium setting
High setting| (750W)
(1250W)
(2000W)| Select switch ‘A’
Select switch ‘B’
Select both switches.
---|---|---
5.3. USING THE THERMOSTAT (fig.2.C)
5.3.1. Once the required room temperature has been achieved, turn the
thermostat down slowly in the direction of the Min. setting until the heat
output switch light (part of each switch) goes out. The heater will then keep
the surrounding air at the set temperature by switching on and off at
intervals. You may reset the thermostat at any time.
5.4. TURBO FAN FEATURE
5.4.1. To boost the output of air at any temperature setting select switch ‘D’
which has a fan symbol beside it. The fan can also be used to circulate cool
air only by switching off the two heat-setting switches.
5.5. TIMER FUNCTION
5.5.1. To activate the timer function, turn the outer ring (fig.2.E) to the
correct time. This will need to be repeated every time that the heater is
reconnected to the power supply.
5.5.2. The function selector switch (fig.2.F) has three positions:
Left…………Heater on permanently
Centre……..Heater timed.
Right………Heater off. – The heater will not operate at all with the switch set
in this position. 5.5.3. To select the time during which the heater is active,
move the timer pins (fig.2.G.) outwards for the period required. Each pin is
equal to 15 minutes.
5.5.4. To switch the unit off, turn the heat selecting switches off and unplug
from the mains.
5.5.5. Allow the unit to cool before handling or storage.
WARNING! DO NOT touch the top of the heater when in use as it becomes
hot.
5.6. SAFETY CUT-OUT FEATURE
5.6.1. The heater is fitted with a thermostatic safety cut out which will turn
the heater off automatically should the airflow become blocked or if
the heater has a technical malfunction.
5.6.2. Should this happen, switch the heater off and unplug it from the mains
power supply.
WARNING! In such a case the heater will be very hot.
DO NOT connect the heater to the power supply again until the reason the
safety cut-out activated has been identified.
5.6.3. Allow the heater to cool completely before handling and then check the
air inlet and outlet for obstructions before attempting to switch the unit
back on.
5.6.4. If the cause is not obvious return the heater to your local Sealey
stockist for servicing.
MAINTENANCE
6.1. Before attempting any maintenance ensure the unit is unplugged from the
mains power supply and that it is cool.
6.2. Clean the unit with a soft dry cloth. DO NOT use abrasives or solvents.
6.3. Periodically check the air inlet and outlet to ensure the airway is
clear.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories, and packaging should be sorted, taken to a recycling center, and
disposed of in a manner that is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the
EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications, and component parts without
prior notice.
Important: No Liability is accepted for incorrect use of this product.
Please note that other versions of this product are available. If you require
documentation for alternative versions, please email or call our technical
team at technical@sealey.co.uk or 01284
757505.
Warranty: Guarantee is 12 months from purchase date, proof of which is
required for any claim.
Information requirements for electric local space heaters
Model identifier(s): CD2005TT.V2
Item| Symbol| Value| Unit| Item| Unit
Heat output| Type of heat Input, for electric storage local space heaters only
(select one)
Nominal heat output| | 2.| kW| Manual heat charge control, with integrated
thermostat| Yes No 1
Minimum heat output (indicative)’ figure or NA| Pm,| 0| kW| Manual heat charge
control with room and/or outdoor temperature feedback
‘Enter| Yes No1
Maximum continuous heat output| P ,m„,| 2.| kW| Electronic heat charge Elece
contr with room
outdoor temperature feedback
and/or| Yes No1
| Fan-assisted heat output| Yes No ✓
Auxiliary electricity consumption| Type of heat output/room temperature
control (select one)
At nominal heat output| el| 0.003| kW| Single stage heat output and no room
temperature control| Yes No 1
At minimum heat output| | 0.000| kW| Two or more manual stages, no room
temperature control| Yes No1
In standby mode| use
se| 0.000| kW| With mechanic thermostat room temperature control| Yes 1 No
| With electronic room temperature control| Yes No
Electronic room temperature control plus day timer| Yes I No
Electronic room temperature control plus week timer| Yes No ✓
Other control options (multiple selections possible)
Room temperature control, with presence detection| Yes No 1
Room temperature control, with open window detection| Yes No ✓
With the distance control option| Yes No ✓
With adaptive start control| Yes No ✓
With working time limitation| Yes No ✓
With a black bulb sensor| Yes No ✓
Contact details: Sealey Group, Kempson Way, Suffolk Business Pa k, Bury St
Edmunds, Suffolk, 1P32 7AR. www.sealey.co.uk
vi ERP Table 2
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
01284 703534
sales@sealey.co.uk
www.sealey.co.uk
© Jack Sealey Limited
Original Language Version
CD2005TT.V2 Issue:3 (1) 08/03/22
Documents / Resources
|
SEALEY CD2005TT.V2 2000w Convector Heater with Turbo Timer &
Thermostat
[pdf] Instructions
CD2005TT.V2, 2000w Convector Heater with Turbo Timer Thermostat, 2000w
Convector Heater, CD2005TT.V2, Heater
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>