SEALEY HVD30 Industrial High Velocity Drum Fan Instructions
- June 5, 2024
- SEALEY
Table of Contents
HVD30 Industrial High-Velocity Drum Fan
INSTRUCTIONS FOR:
INDUSTRIAL HIGH VELOCITY
DRUM FAN 30 230V
MODEL: HVD30
HVD30 Industrial High-Velocity Drum Fan
Thank you for purchasing a Sealey product. Manufactured to a high standard
this product will, if used according to these instructions and properly
maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE
OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS. USE THIS PRODUCT CORRECTLY,
AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
SAFETY INSTRUCTIONS
1.1 ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read,
understand and comply with the following: You must check all electrical
products, before use, to ensure that they are safe. You must inspect power
cables, plugs, sockets and any other connectors for wear or damage. You must
ensure that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should
be incorporated in the main distribution board. We also recommend that a
Residual Current Device (RCD) is used. It is particularly important to use an
RCD with portable products that are plugged into a supply that is not
protected by an RCCB. If in any doubt consult a qualified electrician. You may
obtain a Residual Current Device by contacting your Sealey dealer. You must
also read and understand the following instructions concerning electrical
safety.
1.1.1 The Electricity at Work Act 1989 requires all portable electrical
appliances, if used on business premises, to be tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
WARNING! The switch on this fan has components fitted to protect it against a
possible voltage surge. When carrying out regular appliance checks, a voltage
no higher than 250V should be applied for the purposes of insulation testing.
1.1.2 The Health & Safety at Work Act 1974 makes owners of electrical
appliances responsible for the safe condition of those appliances and the
safety of the appliance operators. If in any doubt about electrical safety,
contact a qualified electrician. 1.1.3 Ensure that the insulation on all
cables and on the appliance is safe before connecting it to the power supply.
See 1.1.1. and 1.1.2. and use a Portable Appliance Tester.
1.1.4 Ensure that cables are always protected against short circuits and
overload.
1.1.5 Regularly inspect power supply cables and plugs for wear or damage and
check all connections to ensure that none are loose.
1.1.6 Important : Ensure that the voltage marked on the appliance matches
the power supply to be used and that the plug is fitted with the correct fuse
– see fuse rating at right. 1.1.7 DO NOT pull or carry the appliance by the
power cable.
1.1.8 DO NOT pull the plug from the socket by the cable.
1.1.9 DO NOT use worn or damaged cables, plugs, or connectors. Immediately
have any faulty item repaired or replaced by a qualified electrician. When an
ASTA/BS approved UK 3-pin plug is damaged, cut the cable just above the plug
and dispose of the plug safely. Fit a new plug according to the following
instructions (the UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal E.
b) Connect the BROWN live wire to the live terminal L.
c) Connect the BLUE neutral wire to the neutral terminal N.
d) After wiring, check that there are no bare wires, that all wires have been
correctly connected, that the cable outer insulation extends beyond the cable
restraint, and that the restraint is tight.
Double insulated products, which are always marked with this symbol, are
fitted with live (brown) and neutral (blue) wires only.
To rewire, connect the wires as indicated above – DO NOT connect either wire
to the earth terminal.
1.1.10 Products that require more than 13 amps are supplied without a plug. In
this case, you must contact a qualified electrician to ensure that a suitably
rated supply is available. We recommend that you discuss the installation of
an industrial round pin plug and socket with your electrician.
1.1.11 If an extension reel is used it should be fully unwound before
connection. A reel with an RCD fitted is preferred since any appliance plugged
into it will be protected. The cable core section is important and should be
at least 1.5mm², but to be absolutely sure that the capacity of the reel is
suitable for this product and for others that may be used in the other output
sockets, we recommend the use of 2.5mm² section cable. If the extension reel
is to be used outdoors, ensure it is marked for outdoor use.
1.2 GENERAL SAFETY
WARNING! If a fan falls into water or other liquid, immediately switch off
and disconnect from the mains power supply. Do not touch the fan until the
mains power supply has been disconnected.
X DO NOT stand the fan on its electrical power cable.
X DO NOT insert any objects through the fan guard.
X DO NOT cover the fan when in use.
X DO NOT immerse the fan in water or any other liquid.
X DO NOT allow children to operate the fan.
X DO NOT stand the fan where it may be knocked over or off a surface, or
where the lead may cause a person to trip.
X DO NOT use the fan outdoors.
X DO NOT use an extension cord unless it has been approved by an
electrical authority.
X DO NOT modify speed control or attempt to fit any additional external
speed control device to the fan.
X DO NOT operate the fan where there are harmful, explosive or flammable
gases, fumes or hazardous substances.
When not in use place the fan in its original box or cover the fan to
protect it from dust, and store in a safe, dry, childproof location.
Use recommended parts only, unauthorised parts may be dangerous, and will
invalidate your warranty.
Always disconnect the fan from the power supply when moving it from one
location to another and ensure the fan is standing on a level surface.
The fan airflow is powerful. Before using ensure there are no materials
or items that may be erroneously moved by the stream of air.
Keep the fan clean and maintained in good condition. For electrical
components or motor service contact an authorized service agent.
Disconnect the fan from the mains’ power when not in use, and before
servicing or performing any maintenance.
****Use the fan in dry areas only. Do not use in wet or areas with high
condensation such as showers, pools, etc.
INTRODUCTION AND SPECIFICATION
High-velocity industrial three-speed drum fan suitable for movement of huge
volumes of air. Robust unit with heavy-duty gauge steel casing, guard and
frame. The mobile unit allows control of airflow to exactly where it is
needed. Carefully balanced and fully guarded blades provide quiet and safe
operation. Fitted with BS-approved plug. Suitable for use in industrial,
commercial, agricultural, and automotive workshop and showroom applications.
Fan Diameter: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
760mm(30)
Speeds: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . 3
Speed Range: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
650-950rpm Max.
Power:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190-350W
Supply: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230V
50Hz
Current: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. 0.9-1.9A
OPERATION
WARNING! Ensure you read, understand and apply safety instructions before
using the fan.
3.1.FAN OPERATION
3.1.1The fan is easily transportable by means of the wheels provided. Lift by
the handle on the main body of the fan on the side opposite the wheels and
maneuver the fan into position. Ensure that there is nothing in front of the
fan that may be disturbed when the fan is switched on.
3.1.2 Check that the speed control box situated in the recess in the rear
grill of the fan is set to OFF. Uncoil the power lead from its stowage
position and plug it into the mains power supply. Ensure that the power lead
is not stretched or positioned in such a way as to cause a hazard. Switch the
power on.
3.1.3 Turn the fan on by rotating the control knob from OFF to 1. If a greater
airflow is required turn the knob to the 2 or 3 settings (fig 1).
3.1.4 When you have finished using the fan ensure you turn the speed control
switch to 0 (off) and disconnect the fan from mains power.
3.1.5 Recoil the lead onto the stowage hooks situated within the recess in the
rear grill.
SPARE PARTS
- HVD30.01……………… HANDLE
- HVD30.02 ………….FRONT GRILL
- HVD30.03 ………………SCREW FOR GRILL
- HVD30.04 ………………SWITCH BOX
- HVD30.05……………… MOTOR
- HVD30.06 ………………ELECTRIC MAINS CABLE
- HVD30.07 …………….WASHER FOR WHEEL
- HVD30.08………………. SCREW FOR WHEEL
- HVD30.09…………………………. WHEEL
- HVD30.10…………………… WASHER FOR FOOT
- HVD30.11 ………………..SCREW FOR FOOT
- HVD30.12…………………… FOOT
- HVD30.13………………. RUBBER FOOT
- HVD30.14 ………………WASHER FOR RUBBER FOOT
- HVD30.15 ……………………….SCREW FOR RUBBER FOOT
MAINTENANCE
WARNING! Ensure the fan is disconnected from the mains power supply
before attempting any of the following:
5.1 Use a soft, damp cloth to clean the body of the fan. DO NOT splash water
onto the fan and never allow water to drip onto the motor housing. DO NOT use
solvents, petroleum, paint thinner or other chemicals to clean the fan.
5.2 If it becomes necessary to clean the fan blades or inside the fan body,
remove the front grill by undoing the 12 screws. Wipe with a damp cloth only.
Replace the grill and re-fix using the screws.
5.3 Should the motor, speed control box or the power lead require service or
maintenance contact your local service agent. 5.4 When not in use place the
fan in its original box or cover the fan to protect from dust, and store in a
safe, dry, childproof location.
DECLARATION OF CONFORMITY
Declaration of Conformity We, the sole importer into the UK, declare that
the products listed below are in conformity with the following standards and
directives.
IND. HIGH-VELOCITY PEDESTAL FAN Models HVF16 & HVF18.V3
89/336/EEC EMC Directive
/23/EEC Low Voltage Directive
93/68/EEC CE Marking Directive
The construction files for these products are held by the Manufacturer and may
be inspected, by a national authority, upon request to Jack Sealey Ltd.
Signed by Mark Sweetman
20th November 2006
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
NOTE: It is our policy to continually improve products and as such, we
reserve the right to alter data, specifications, and component parts without
prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will
be required for any claim.
INFORMATION: For a copy of our catalog and latest promotions call us on
01284 757525 and leave your full name, address and postcode.
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
01284 757500
01284 703534
www.sealey.co.uk
email sales@sealey.co.uk
HVF16 & HVF18.V3 – 1 – 20/11/06
Get In Touch
**Call: 0845 6880112
Email: info@adremit.co.uk
Our Address**
Prevent, Adremit Limited, Unit 5a, Commercial Yard
Settle, North Yorkshire, BD24 9RH
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>