SEALEY IWMH2003RC Wall Mounting Infrared Quartz Heater Instructions
- June 5, 2024
- SEALEY
Table of Contents
IWMH2003RC Wall Mounting Infrared Quartz Heater
Instructions
INSTRUCTIONS FOR:
INFRARED QUARTZ HEATER WALL MOUNTING WITh REMOTE CONTROL MODEl: IWMh2003RC
Thank you for purchasing a Sealey product. Manufactured to a high standard
this product will if used according to these instructions and properly
maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ ThESE INSTRUCTIONS CAREFULLY. NOTE ThE SAFE
OPERATIONAL REqUIREMENTS, WARNINGS, AND CAUTIONS. USE ThIS PRODUCT CORRECTLY
AND WITh CARE FOR ThE PURPOSE FOR WhICh IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE ThE WARRANTY.
SAFETY INSTRUCTIONS
1.1 ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read,
understand and comply with the following: You must check all electrical
products, before use, to ensure that they are safe. You must inspect power
cables, plugs, sockets and any other connectors for wear or damage. You must
ensure that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should
be incorporated in the main distribution board. We also recommend that a
Residual Current Device (RCD) is used. It is particularly important to use an
RCD with portable products that are plugged into a supply that is not
protected by an RCCB. If in any doubt consult a qualified electrician. You may
obtain a Residual Current Device by contacting your Sealey dealer. You must
also read and understand the following instructions concerning electrical
safety.
1.1.1 The Electricity at Work Act 1989 requires that all portable electrical
appliances if used on business premises, are tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2 The Health & Safety at Work Act 1974 makes owners of electrical
appliances responsible for the safe condition of those appliances and the
safety of the appliance operators. If in any doubt about electrical safety,
contact a qualified electrician.
1.1.3 Ensure that the insulation on all cables and on the appliance is safe
before connecting it to the power supply. See 1.1.1 and 1.1.2 and use a
Portable Appliance Tester.
1.1.4 Ensure that cables are always protected against short circuits and
overload.
1.1.5 Regularly inspect power supply cables and plugs for wear or damage and
check all connections to ensure that none are loose.
1.1.6 Important: Ensure that the voltage marked on the appliance matches the
power supply to be used and that the plug is fitted with the correct fuse –
see fuse rating at right.
1.1.7 DO NOT pull or carry the appliance by the power cable.
1.1.8 DO NOT pull the plug from the socket by the cable.
1.1.9 DO NOT use worn or damaged cables, plugs or connectors. Immediately have
any faulty item repaired or replaced by a qualified electrician. When a BS
1363/A UK 3-pin plug is damaged, cut the cable just above the plug and dispose
of the plug safely. Fit a new plug according to the following instructions
(the UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal E’. b) Connect the BROWN live wire to the live terminal
L’.
c) Connect the BLUE neutral wire to the neutral terminal `N’.
d) After wiring, check that there are no bare wires, that all wires have been
correctly connected, that the cable outer insulation extends beyond the cable
restraint, and that the restraint is tight. Double insulated products, which
are always marked with this symbol, are fitted with live (brown) and neutral
(blue) wires only. To rewire, connect the wires as indicated above – DO NOT
connect either wire to the earth terminal.
1.1.10 Products that require more than 13 amps are supplied without a plug. In
this case, you must contact a qualified electrician to ensure that a suitably
rated supply is available. We recommend that you discuss the installation of
an industrial round pin plug and socket with your electrician.
1.1.11 Use of an extension cord is not recommended. If an extension reel must
be used it should be fully unwound before connection. A reel with an RCD
fitted is preferred since any appliance plugged into it will be protected. The
cable core section is important and should be at least 2.5mm².
1.2 GENERAL SAFETY INSTRUCTIONS
IWMH2003RC Issue No: 1 – 20/05/08
Familiarise yourself with the applications and limitations of the
heater.
Ensure the heater is in good order and condition before use. If in any
doubt do not use the unit and contact an electrician or your Sealey dealer.
Only use recommended attachments and parts.
Using unauthorized parts may be dangerous and will invalidate your
warranty.
Check that element guards are in place, undamaged, and firmly attached.
Keep tools and other items away from the heater when it is in use.
Keep the work area clean and clear of unnecessary items.
Keep children and unauthorized persons away from the heater, as it gets
very hot.
** Disconnect from mains and allow to cool before moving or attempting any
cleaning or maintenance.
X DO NOT get the heater wet or use in damp or wet locations or areas
where there is condensation.
X DO NOT locate the heater below the power outlet.
X DO NOT move the heater whilst in operation or even when still warm.
X DO NOT touch the heater elements, even when cold.
X DO NOT dismantle the heater for any reason. The heater must be checked
by qualified personnel only.
X DO NOT use this product to perform a task for which it has not been
designed.
WARNING! If a fuse blows, ensure it is replaced with an identical fuse
type and rating.
** When not in use, store the heater carefully in a safe, dry, childproof
location.
WARNING! Never touch the element glass directly with your fingers. Use a
soft cloth, otherwise, the tube may get damaged.
WARNING! Ensure the heater is at least 90cm from any object.
INTRODUCTION & SPECIFICATION
A totally dry heat, no condensation, no gas, no fumes and no smell. Reaches
maximum heat output within seconds of being turned on. Highly polished
aluminum reflector for maximum heat efficiency. Adjusts horizontally through
25° while mounted. Three settings, controlled by push on/off switch or remote
control, allowing the unit to be on full, half or low power. Ideal for
industrial or domestic applications. Suitable for indoor and outdoor use, if
weather protected.
Power:……………………. 2000W
Input supply:………………………. 230V 50Hz 13A
Dimensions (W x H x D)…………………….. 485 x 250 x 170mm
MOUNTING INSTALLATION
3.1 WALL MOUNTING (fig.1).
(IMPORTANT! The following points should be noted): The heater should always
have a minimum clearance of 450mm from a ceiling and at least 90cm from any
object. Ensure that the mounting surface is capable of supporting the weight
of the heater.
3.2 Remove the metal bracket from the heater by removing the single screw from
the underside of the bracket and sliding the bracket down.
3.3 Use the bracket as a template, fix the metal bracket to the wall by means
of the four holes and appropriate fixings.
3.4 Slide the heater back onto the bracket and secure using the single screw.
3.5 Adjust the angle of the heater to direct heat where required.
OPERATION
Note: The infrared lamp is fragile and therefore it is important that it
is not subjected to any unnecessary shocks or vibration and is not moved when
it is on or still warm. Only move once completely cooled down.
WARNING! Ensure you read, understand and apply the safety instructions in
Section 1 before using the heater.
4.1 Ensure the heater is at least 90cm from any object. The heater can be
tilted from 0° to 25°, set it to the required angle before switching the
heater on.
4.2 Plug in the heater and switch it on using either the control on the base
of the heater or by using the remote.
4.3 The heater will start on the low setting, each press of the on/power
button will cycle the heater onto the medium setting, high setting, and then
back to the low setting.
4.4 When the heater is no longer required, switch off, using the off button on
the unit or the off button on the remote, and unplug the unit.
4.5 Make sure the heater plug is disconnected from the main supply before any
cleaning is attempted. Also, allow the heater to cool
completely. DO NOT use water or other liquids, or harsh abrasive cleaners to
clean the heater. DO NOT touch the glass elements with fingers as this may
damage the tube(s). 4.6 Clean the exterior with a soft damp cloth with some
mild detergent.
4.7 To replace any of the lamps, contact your authorized Sealey dealer.
4.8 To change the remote batteries, press down and push back the battery cover
(fig.2), remove old batteries and replace with two new AAA batteries.
WARNING! DO NOT mix old and new batteries and dispose of old batteries in
accordance with local authority regulations.
DECLARATION OF CONFORMITY
Declaration of Conformity We, the sole importer into the UK, declare that
the products listed below are in conformity with the following standards and
directives.
IND. HIGH-VELOCITY PEDESTAL FAN Models HVF16 & HVF18.V3
INFRARED QUARTZ HEATER
Model: IWMH2003
73/23/EEC Low Voltage Directive
89/336/EEC EMC Directive
93/68/EEC Marking Directive
2002/95/EC RoHS Directive
2002/96/EC WEEE Directive
The construction files for these products are held by the Manufacturer and may
be inspected, by a national authority, upon request to Jack Sealey Ltd.
Signed by Mark Sweetman
20th November 2006
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
NOTE: It is our policy to continually improve products and as such, we
reserve the right to alter data, specifications, and component parts without
prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will
be required for any claim.
INFORMATION: For a copy of our catalog and latest promotions call us on
01284 757525 and leave your full name, address and postcode.
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
01284 757500
01284 703534
www.sealey.co.uk
email sales@sealey.co.uk
HVF16 & HVF18.V3 – 1 – 20/11/06
Get In Touch
**Call: 0845 6880112
Email: info@adremit.co.uk
Our Address**
Prevent, Adremit Limited, Unit 5a, Commercial Yard
Settle, North Yorkshire, BD24 9RH
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>