SEALEY EH2000 Industrial Fan Heaters Instructions
- June 5, 2024
- SEALEY
Table of Contents
InstructIons for:
INDUSTRIAL FAN HEATERS
Model No: EH2000 & EH3300
Thank you for purchasing a Sealey Fan Heater. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble-free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE
OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS.
USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS
INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
SAFETY INSTRUCTIONS
ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read,
understand and comply with the following:
You must check all electrical products, before use, to ensure that they are
safe. You must inspect power cables, plugs, sockets, and any other connectors
for wear or damage. You must ensure that the risk of electric shock is
minimized by the installation of appropriate safety devices. A residual
current circuit breaker (ECB) should be incorporated into the main
distribution board. We also recommend that a residual current Device (rcD) is
used. It is particularly important to use an rcD with portable products that
are plugged into a supply that is not protected by an ECB. If in any doubt
consult a qualified electrician. You may obtain a residual current Device by
contacting your Sealey dealer.
You must also read and understand the following instructions concerning
electrical safety.
1.1.1. the Electricity at Work Act 1989 requires that all portable electrical
appliances if used on business premises, are tested by a qualified
electrician, using a Portable Appliance tester (PAt), at least once a year.
1.1.2. the Health & Safety at Work Act 1974 makes owners of electrical
appliances responsible for the safe condition of those appliances
and the safety of the appliance operators. If in any doubt about electrical
safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe
before connecting it to the power supply. see 1.1.1. and 1.1.2. and use a
Portable Appliance tester.
1.1.4. Ensure that cables are always protected against short circuits and
overload.
1.1.5. regularly inspect power supply cables and plugs for wear or damage and
check all connections to ensure that none is loose.
1.1.6. Important: Ensure that the voltage marked on the appliance matches the
power supply to be used and that the plug is fitted with the correct fuse –
see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Immediately
have any faulty item repaired or replaced by a qualified electrician. When a
Bs 1363/A uK 3 pin plug is damaged, cut the cable just above the plug and
dispose of the plug safely.
fit a new plug according to the following instructions (uK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been
correctly connected, that the cable outer insulation extends beyond the cable
restraint, and that the restraint is tight.
Double insulated products, which are always marked with this symbol, are
fitted with live (brown) and neutral (blue) wires only. to rewire, connect the
wires as indicated above.
DO NOT connect either wire to the earth terminal.
1.1.10. Products that require more than 13 amps are supplied without a plug.
In this case, you must contact a qualified electrician to ensure that a
suitably rated supply is available. We recommend that you discuss the
installation of an industrial round pin plug and socket with your electrician.
1.1.11. If an extension reel is used it should be as short as possible and
fully unwound before connection. A reel with an rcD fitted is preferred since
any appliance plugged into it will be protected. the cable core section is
important and should be at least 1.5mm, but to be absolutely sure that the
capacity of the reel is suitable for this product and for others that may be
used in the other output sockets, we recommend the use of 2.5mm ² section
cable.
GENERAL SAFETY
- WARNING! Disconnect the heater from the mains power, before servicing or performing any maintenance. servicing or maintenance must only be carried out by an authorized service agent.
- check that the heater is in sound condition and in good working order. Take immediate action to repair or replace damaged parts.
- use recommended parts only. Unapproved parts may be dangerous and will invalidate the warranty.
- Keep the heater a minimum of 0.5m (back and sides) and 1.8m (front) from any walls and objects.
- WARNING! DO NOT use the heater near flammable material, liquids, solids, gases or compressed gas cylinders and the like.
- DO NOT obstruct the air inlet and outlet sections of the heater.
- DO NOT cover the heater.
- DO NOT operate the heater when you are tired or under the influence of alcohol, drugs or intoxicating medication.
- DO NOT touch the heater casing or grill when first switched off as these are hot and will take time to cool.
- DO NOT use the heater for anything other than its intended purpose. It is designed for providing heat in enclosed areas, no smaller than 4m , such as workshops and other industrial areas. It is not suitable for drying clothes or laundry.
- DO NOT place the heater close to a bath, wash basin, shower, swimming pool or any other water-filled area or wet surface.
- DO NOT get the heater wet or use in areas of high condensation.
- DO NOT place the heater up against any surface such as a wall, door or furniture, etc. \
- DO NOT place the heater immediately below any electrical outlet. DO NOT allow the power lead to touch the radiator surface.
- DO NOT attempt to repair a damaged heater, contact an authorized service agent.
- DO NOT stand on the heater.
- DO NOT connect the fan heater to a timer device or other equipment that can automatically switch the heater on or off.
- only use the heater in an upright position.
- Ensure that the heater is correctly turned off when not in use and stored in a safe, dry area, out of reach of children.
SPECIFICATIONS
Electric fan heaters for industrial applications. selectable heat settings
with thermostat control. Totally dry heat with no condensation, no gas, no
fumes, so no smell. Ideal for workshops, garages etc.
Model ………………………………EH2000 ……………………………. EH3300
Voltage/frequency:…………………. 230V ~50Hz ………………………….230V ~50Hz
Power rating:………………………….2000W ……………………………..3300W
settings: . . . . . . . . . . . . . . . . . . . . . 650W – 1300W – 2000W
……………40W(fan only) – 1650W – 3300W
Dimensions: ………………… 197 x 210 x 313mm …………………….250 x 250 x 398mm
Weight: ……………………………….4.2kg ……………………………… 5.6kg
fuse:………………………………….13A ………………………………..30A
Note: EH3300 requires a 30A fuse. Contact a qualified electrician to ensure
that a suitably rated supply is available.
We recommend that you discuss the installation of an industrial round pin plug
and socket with your electrician.
IMPORTANT! this unit is designed to raise the ambient temperature of an entire room, the temperature of the air coming out of the front of the heater will be warmer than the general temperature of the room, but there may not be a significant increase due to the large volume of air passing over the element. for the same reason, the element is hot during operation but does not visibly glow. the room temperature depends on room size, insulation, and the ambient temperature, which will increase as the room gets warmer.
OPERATION
3.1 Position heater in an upright position on a firm surface and at a safe
distance from any obstructions, flammable substances etc, see fig 1.
3.2 connect the heater to a suitable mains supply. (for EH3300, see note in
specifications above).
3.3 set the thermostat dial to the maximum setting (fully clockwise).
3.4 the fan heater will switch on when the power setting selector is set to
one of the three power settings (fig 2, fig 3).
NOTE: It will take up to three minutes for the heater to reach optimum
temperature.
3.5 once the room reaches the required temperature, turn the thermostat dial
slowly counter-clockwise until you hear the thermostat click, this will
maintain the room temperature at this setting. the fan will continue to
operate until the power switch is turned to the off position.
3.6 for fan-only operation on model EH2000 select the first power setting but
set the thermostat to a minimum.
MAINTENANCE
WARNING! Before attempting any maintenance ensure the unit is unplugged from
the mains power supply and that it is cool.
4.1. clean the heater with a soft dry cloth. DO NOT use abrasives or solvents.
4.2. Periodically check the heater grille to ensure it is not blocked.
no other maintenance is necessary. If you experience a problem with your
heater or if the power lead or plug is damaged contact your local authorized
service agent for repair. DO NOT dismantle or tamper with the heater as this
may be dangerous and will invalidate your warranty.
NOTE: It will take up to three minutes for the heater elements to reach
optimum temperature. This is normal and not a fault.
DECLARATION OF CONFORMITY
Declaration of Conformity
INDUSTRIAL FAN HEATER
Models: EH2000 & EH3300
2006/95/Ec Low Voltage Directive
2004/108/Ec EMC Directive
93/68/EEC CE Marking Directive
We, the sole importer into the UK, declare that the products listed below are
in conformity with the following standards and directives
the construction file for these products are held by the Manufacturer and may
be inspected, by a national authority, upon request to Jack Sealey Ltd.
2008 signed by Mark Sweetman 4th February
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products
NOTE: It is our policy to continually improve products and as such, we
reserve the right to alter data, specifications, and component parts without
prior notice.
IMPORTANT: no liability is accepted for incorrect use of the product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will
be required for any claim.
INFORMATION: for a copy of our latest catalog and promotions call us on
01284 757525 and leave your full name and address, including postcode.
Sole UK Distributor
Sealey Group,
Bury st. Edmunds, Suffolk.
01284 757500
01284 703534
**** www.sealey.co.uk
sales@sealey.co.uk
EH2000, EH3300 – 3 – 050208 Get In Touch
Call: 0845 6880112
Email:
info@adremit.co.uk
Our Address
Prevent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>