cecotec Surface Precision 9600 Smart Health Bathroom Scale Instruction Manual
- June 3, 2024
- cecotec
Table of Contents
- cecotec Surface Precision 9600 Smart Health Bathroom Scale
- SAFETY INSTRUCTIONS
- Battery instructions.
- PARTS AND COMPONENTS
- BEFORE USE
- OPERATION
- MOBILE APP
- WARNING NOTIFICATIONS
- CLEANING AND MAINTENANCE
- TECHNICAL SPECIFICATIONS
- DISPOSAL OF OLD ELECTRICAL APPLIANCES
- TECHNICAL SUPPORT AND WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
cecotec Surface Precision 9600 Smart Health Bathroom Scale
SAFETY INSTRUCTIONS
Read these instructions thoroughly before using the appliance. Keep this
instruction manual for future reference or new users. This device is designed
for personal use only and is not suitable for commercial use. Keep the device
away from electromagnetic fields (mobile telephones, remote controls, etc.).
Measurement accuracy could be affected.
Keep the device and its packaging out of the reach of children and animals
when not supervised. Do not use the device if it shows visible signs of
damage. If the cord is damaged, it must be replaced by the official Technical
Support Service of Cecotec in order to avoid any type of danger. Keep the
device away from electromagnetic fields such as mobile telephones, remote
controls, etc. Measurement accuracy could be affected. Keep the device away
from heat sources. Do not use the device outdoors. Do not expose the device to
extreme temperatures, moisture, wet conditions or direct sunlight. Keep water
and other liquids away from the device. Wide temperature variations could
cause condensation. In this case, allow the device to go back to room
temperature before use. Do not drop the device or jump on its measuring
surface. Do not stand on the scale with wet feet and make sure the measuring
surface and the surface underneath is dry. Do not stand on the edge of the
scale. Do not use caustic or abrasive cleaning materials to clean the device,
this could damage the surface. This scale is intended to be used for
determining bodyweight, analysing water, body fat, muscle and bone mass
proportion in the body, body age, visceral fat, metabolism, physical
conditions and calculating Body Mass Index (BMI). BMI function is only
suitable for calculating the ideal weight of adults aged 18 and above. The
calculated results are simple reference values. Do not use these results as
the basis for any form of medical treatment or diet and contact a professional
for any doubt. Body analysis function is not suitable for:
People under the age of 10 or over the age of 70. People with a pacemaker or
any other medical implant with electronic components. People with fever,
oedema or osteoporosis symptoms. People undergoing dialysis treatment. People
who are taking cardio-vascular medication. Pregnant women. The device
withstands a maximum body weight of 180 kg.
Battery instructions.
Keep batteries away from children and animals, they could be deadly if
swallowed. In case of ingestion, seek medical assistance immediately. Should a
battery have leaked, do not allow your skin, eyes or mucous membranes to come
into contact with the battery acid. In case of contact with acid, rinse the
affected areas with abundant fresh water immediately and contact a doctor as
soon as possible. Make sure the battery contacts in the device are clean
before inserting batteries; if they are not, clean them. Use only the battery
type specified in the technical specifications. Always replace all the
batteries at the same time. Do not use different types of batteries or of
different capacities.
When replacing batteries, note the correct polarity (+/-). Take the batteries
out of the device when they are discharged or when the device is not going to
be used in a long time. Batteries must not be recharged or reactivated,
dismantled, thrown into fire, immersed in fluids or short-circuited. This
device requires 4 x 1.5-volt batteries, AAA type.
Warning:
If “Lo” appears on the display, batteries need to be replaced.
Replacing batteries:
Open battery compartment on the bottom part of the scale. Remove used
batteries. Introduce 4 x 1.5-volt batteries, AAA type. Pay attention to
polarity.
PARTS AND COMPONENTS
- Display
- Right foot contact area
- Left foot contact area
- High-precision sensor
- Battery cover
- Body measuring tape
BEFORE USE
Take the product out of the box. Check carefully if there is any damage, and
if there is, immediately notify the Technical Support Service of Cecotec.
Remove the protective strip from the battery compartment, located on the
bottom part of the device, in order to activate it. This protective strip is
placed for a more secure transportation.
Further information
Weight yourself without any clothing and barefoot. It is suggested to weigh
yourself at the same time and always under the same circumstances. Measured
values might be distorted if weight is measured immediately after doing sport
or if you have not eaten or drunk enough over the day. Measurement of body
fat, water content and muscle and bone mass is only possible with bare and dry
feet. The scale reacts to a minimum weight of 5 kg and rounds up weight to
whole 100 g. Measuring surface must be clean in order to work properly.
OPERATION
Normal mode
Place the device on a solid, dry and flat surface (avoid carpets). Uneven
floors will result in inaccurate measurement results. Tap your foot on the
scale in order to activate the display. Wait until display shows ‘0.0’
(kg/lb/st). Before standing on the scale, select unit of measure: kg, lb or
st. See the Measuring unit setting section. Stand on the scale, the device
will star calculating weight. Once the weight has been established, the number
on the display will flash. You can now get off the scale. The device will
automatically turn off after a few seconds.
Baby weight function
This function is designed to automatically obtain precise small weight
results. This function allows seeing, activating and checking the evolution of
weight from the App (see mobile APP).
- This option is also suitable for weighing pets and baggages.
MOBILE APP
Scan the QR code in order to download and install the last version of the app Surface Precision, or search for it in Google Play, App Store pr any other App store of third parties. Open the App and follow the instructions in it to link and start using the scale.
WARNING NOTIFICATIONS
The following warning notifications may appear on the display:
Display | Meaning |
---|---|
Lo | The batteries in the scale are too low. Insert new batteries (see the |
“Replacing the batteries” section).
Err| The weigh on the scale is over 180 kg, the scale does not withstand the
weight.
C| An error has occurred during measurement. Step off the scale and step on it
again to repeat the measuring process.
Possible errors
Error | Possible meaning |
---|---|
Non-plausible values for body fat and water content. | Body fat includes |
relatively little water. This means the body’s water content may be below the
guideline figures in people who have a high body fat content. In case of
endurance or performance athletes,
by contrast, the guideline figures may be exceeded due to the lower fat
contents and the high proportion of muscle.
Incorrect weight measurement.| The scale is positioned on an uneven surface
(e.g. a carpet). The measured values may be distorted if the surface
underneath is uneven.
No values for body fat and water content can be calculated. Feet must be
properly placed on the feet contact area, bare and dry.
CLEANING AND MAINTENANCE
Never immerse the device in water or other liquids. No liquid must be allowed to enter the device during cleaning. Do not use any caustic or abrasive cleaning agents to clean the device. These can damage the surface. Clean the device with a slightly dampened, soft cloth and, if necessary, a mild cleaning agent. When not in use, store the device in a dry, clean place which is protected from direct sunlight and is out of the reach of children.
TECHNICAL SPECIFICATIONS
- 04090 Surface Precision 9500 Smart Healthy
- 04091 Surface Precision 9600 Smart Healthy
- Maximum load: 180 kg
- Supply: 6 V (4xAAA batteries)
- Size:
- 9500: 310 x 310 x 20 mm
- 9600: 310 x 310 x 20 mm
- Measuring units: Kilo (kg) / Stone (st) / Libra (lb)
- Net weight:
- 9500: 2 kg
- 9600: 1.86 kg
- Display: 82*44 mm
- Users: 8
- Functions: 10
DISPOSAL OF OLD ELECTRICAL APPLIANCES
The European directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE), specifies that old household electrical appliances must not be disposed of with the normal unsorted municipal waste. Old appliances must be collected separately, in order to optimize the recovery and recycling of the materials they contain, and reduce the impact on human health and the environment. The crossed out “wheeled bin” symbol on the product reminds you of your obligation to dispose of the appliance correctly. If the product has a built-in battery or uses batteries, they should be removed from the appliance and disposed of appropriately. Consumers must contact their local authorities or retailer for information concerning the correct disposal of old appliances and/or their batteries.
TECHNICAL SUPPORT AND WARRANTY
This product is under warranty for 2 years from the date of purchase, as long
as the proof of purchase is submitted, the product is in perfect physical
condition, and it has been given proper use, as explained in this instruction
manual.
The warranty will not cover the following situations:
The product has been used for purposes other than those intended for it,
misused, beaten, exposed to moisture, immersed in liquid or corrosive
substances, as well as any other fault attributable to the customer. The
product has been disassembled, modified, or repaired by persons, not
authorised by the official Technical Support Service of Cecotec.
Faults deriving from the normal wear and tear of its parts, due to use. The
warranty service covers every manufacturing defects of your appliance for 2
years, based on current legislation, except consumable parts. In the event of
misuse, the warranty will not apply. If at any moment you detect any problem
with your product or have any doubt, do not hesitate to contact Cecotec
Technical Support Service at +34 963 210 728.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>