Appearance

Hikvision-DS-PDBG8-EG2-Wired-Glass-Break-Detector-
FIG-1

  1. Front Panel
  2. LED Light Pipe
  3. PCB
  4. Rear Pane

The Printed Circuit Board (PCB)

  1. Tamper Resistor Headers
  2. Alarm Resistor Headers
  3. Sensor
  4. Adjustable Resistance (Detection range: 0 to 8 m)
  5. Terminal
  6. Tamper
  7. Alarm LED Latch/Normal

Hikvision-DS-PDBG8-EG2-Wired-Glass-Break-Detector-
FIG-6

ResistorWiring

Hikvision-DS-PDBG8-EG2-Wired-Glass-Break-Detector-
FIG-2

  • Method 1: Use the jumper to select EOL (End of Line) resistance on ALARM/TAMPER pins.
  • Method 2: Add the resistor to ALARM/TAMPER wiring ports.

Note: If EOL wiring is not used, leave the jumpers OFF. Do not force the jumper if it is not matched the pin. Method 1 & 2 should not be used on the ALARM/TAMPER at the same time.

  • a. Alarm Resistance: 1K, 2K2, 4K7, 5K6, 6K8
  • b. Tamper Resistance: 1K, 2K2, 4K7, 5K6

Connection Type

Hikvision-DS-PDBG8-EG2-Wired-Glass-Break-Detector-
FIG-3

  1. Detector
  2. Alarm Control Panel

Note:
The resistor must be connected in series with one end of the detector.

  • a. Normally Closed
  • b. Double End of Line Wiring:
    The connection example: Normal: 1K, Alarm: 4.4K, Tamper: Infinite

Test

Installation

Hikvision-DS-PDBG8-EG2-Wired-Glass-Break-Detector-
FIG-5

SPECIFICATIONS

Hikvision-DS-PDBG8-EG2-Wired-Glass-Break-Detector-
FIG-7

  • Not to obscure partially or completely the detector’s field of view with large objects such as furniture, curtains, blinds, etc.
  • Make sure that any curtains, plants, furniture, or other objects do not overcover the microphone opening.
  • If there are curtains on the window, place the detector between them and the window, for instance, at the window side jamb. Otherwise, curtains can mute the glass break sound, and the detector will not be triggered.
  • Before installing the detector, make sure that you have select the optimal location that follows the guidelines of this manual:
    • Avoid mounting the detector on the same wall as the protected glass.
    • Avoid mounting the detector in rooms with noisy equipment (air compressors, power tools, bells, etc.)
    • Avoid mounting the detector in humid rooms (bathroom, etc.)
    • Avoid mounting the detector on the wall with strong vibration.