GUDE UVH-600-2000 Hot air weed killer Instructions
- June 5, 2024
- Gude
Table of Contents
UVH 600-2000 l
94310
GÜDE GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Deutschland
Please read the instructions carefully before starting the machine
STARTING-UP THE MACHINE
DELIVERED ITEMS
Assembly
Operation
Technical Data
Hot air weed killer UVH 600-2000 l
Art. No 94310
Service connection 230 V ~ 50 Hz
Rated input 2000 W
Air volume
Level 1 500 l/min
Level 2 500 l/min
Air temperature
Level 1 50 °C
Level 2 600 °C
Weight 0,85 kg
Read and understand the operating instructions before using the appliance. Familiarize with the control elements and how to use the appliance properly. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.
The operator is responsible for accidents or risks to third parties.
In case of any doubts about connection and operation refer please to our customer center
WARNING Read all safety warnings and all instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference.
Safety Warnings Hot air weed killer
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
WARNING: Switch the device off when it is not in use.
Danger of fire if not used properly!
Take care if using the device in the vicinity of combustible materials. Do not
direct the device towards the same place for long periods.
Do not use the device in rooms with a potentially explosive atmosphere.
Do not use the device in rooms in which easily flammable material or gases may
be present.
Heat can be conducted to combustible materials that are concealed.
Do not leave the device unattended while switched on.
Do not use the device outside if it is raining.
Never cover or close the hot air nozzle.
Do not point the hot air flow at people.
Do not use the device as a hair dryer.
Allow the device to cool down for a while after use before packing it away.
Keep all body parts away from the heating element and the heat shield
(including the nozzle). Do not
touch any hot surfaces before they have cooled down completely.
Carry the device by the handle when the heat shield (including the nozzle) has
cooled down.
Hold the power tool by the insulated handle surfaces only, since the heat
shield (including the nozzle) may come into contact with concealed power lines
or the power tool’s own power cable.
Always keep the power cable away from the machine’s nozzle.
The connecting line or other combustible materials must not come into contact
with the hot parts of the device.
Unsuitable extension cables may be dangerous. If an extension cable is used,
it must be suitable for
outdoor use and the connection must be dry and situated above ground level. It
is advisable to use a
cable reel that keeps the socket at least 60 mm above ground level for this
purpose.
Switch the device off before removing it from the fire to avoid flying sparks.
Specified Conditions Of Use
The device serves exclusively for removing uncontrolled growth between
flagstones, on paved areas,
on masonry, in garden beds as well as in lawns during the growing period.
The device can also be used for lighting barbecue charcoal in outdoor
barbecues.
Please observe the notes on use and regulations of the barbecue manufacturer
for this.
The device is suitable for soldering copper pipes, galvanizing bodywork parts,
welding plastics, thawing out water pipes or heating metal parts
You can find special nozzle attachments in our range.
This device is intended for domestic use only.
Do not use this product in any other way as stated for normal use. Not
observing general regulations
in force and instructions from this manual does not make the manufacturer
liable for damages.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. If you seek help, state the following pieces of information: 1. Accident site, 2. Accident type, 3. Number of injured persons, 4. Injury type(s)
Symbols
WARNING / Caution!
WARNING! Danger of burns
Read the operating instructions to reduce the risk of injury.
Wear eye protective goggles !
Wear ear protectors!
Wear gloves!
Unplug the machine before any work on it.
Keep dry at all times. Never expose tool to rain.
Do not use the device in rooms with a potentially explosive atmosphere. Do not use the device in rooms in which easily flammable material or gases may be present. Do not point the hot air flow at people
Class II tool.
CE marking
Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.
Mains Connection
Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA).
Connect only to single-phase AC system voltage as indicated on the rating
plate. It is also possible to
connect to sockets without an earthing contact as the design conforms to
safety class II. Only plug-in when machine is switched off .
Maintenance
Unplug the machine before any work on it
Repairs and works specified in these Instructions may only be performed by
qualified authorized staff .
Use only original accessories and original spare parts.
Keep the device, in particular the air vents, clean at all times. Never spray
water on the device body!
Do not clean the plastics with solvents, flammable or toxic fluids. For
cleaning, use a damp cloth only.
Caution! If the power cord of the appliance gets damaged, it must be replaced
by the manufacturer or
its customer service or a similarly qualified person to avoid danger.
Only a regularly maintained and treated appliance can serve as a satisfactory
aid. Insufficient maintenance and care can lead to unforeseen accidents and
injuries.
If necessary, a list of spare parts can be found at
www.guede.com
Translation of the EC-Declaration of Conformity
We, hereby declare the conception and construction of the below mentioned appliances correspond – at the type of construction being launched – to appropriate basic safety and hygienic requirements of EC Directives. In case of any change to the appliance not discussed with us the Declaration expires.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | | | | |
94310 UVH 600-2000 I
Directives CE applicable
2014/35/EU 2014/30/EU
1935/2004/ EC 1907/2006/EC
2011/65/EC ROHS 2009/142/EC
89/686/EEC (PPE) 2009/105/EG (…<20.04.2016)
2006/42/EC 2014/29/EU (…>20.04.2016)
Annex IV
Notified Body Name:
No: Adress:
Type Ex. Cert.-No.:
97/68/EC_
Emission No.:
2000/14/EC_2005/88/EC
Konformitätsbewertungsverfahren
Method of compliance assessment
Angewandte harmonisierte Norman
Harmonized standards used
EN 60335-2-45:2002/A2:2012
EN 60335-1:2012/A11:2014
EN 62233:2008
AfPS GS 2014:01 PAK
EN 55014-1:2006/A2:2011
EN 55014-2:1997/A2:2008
EN 61000-3-2:2014 EN 61000-3-3:2013
Garantierter Schallleistungspegel
Guaranteed sound power level
LWA dB (A)
Gemessener Schallleistungspegel
Measured sound power level
LWA dB (A)
GÜDE GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
eMail: info@guede.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>