Laserliner 082-086 Thermo Camera Connect User Manual

June 5, 2024
Laserliner

Laserliner-logo

Laserliner 082-086 Thermo Camera Connect

Laserliner-082-086-Thermo-
Camera-Connect-product

Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and passed on together with the device.

Function/Application

The ThermoCamera Connect is used to visually display thermal patterns and enables non-contact measurement of surfaces by evaluating the radiation in the infrared wavelength range via the integrated non-chilled microbolometer. The imaging technology of the sensor provides a visual image of the temperatures surrounding the inspected object. The temperature differences can be visualized by color-coding the individual temperatures in a thermogram with a false color display. Possible applications include locating overloads in electrical components, detecting overheating in mechanical components, pinpointing and analyzing heating lines in walls and floors, assessing refrigerant and air conditioning systems and much more.

General safety instructions

  • The device must only be used in accordance with its intended purpose and within the scope of the specifications.
  • The measuring tools and accessories are not toys. Keep out of reach of children.
  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
  • Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.
  • Use only genuine accessories. Use of inappropriate accessories will invalidate the warranty.
  • The charging progress can be viewed by briefly pressing the ON/OFF button.
  • The residual charge of batteries with a weak charge is shown in red.
  • The battery can also be charged while using the device.
  • Disconnect the power pack from the mains when the device is not in use.
  • Never use extension cables in conjunction with the battery charger, or similar accessories not approved by the manufacturer, as this may result in a fire risk, the risk of an electric shock or injury to persons.

Using electromagnetic radiation and RF wireless radiation

  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
  • The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.
  • The measuring device is equipped with a wireless interface.
  • The measuring device complies with electromagnetic compatibility and wireless radiation regulations and limits in accordance with the RED 2014/53/EU.
  • Umarex GmbH & Co. KG hereby declares that the ThermoCamera Connect radio equipment complies with the essential requirements and other provisions of the European Radio Equipment Directive 2014/53/EU (RED). The EU Declaration of Conformity can be found in its entirety at the following address: http://laserliner.com/info?an=AGR.
  • This device complies with the CE limit values for radiation exposure as defined for uncontrolled environments. To avoid wireless radiation, this device should be used at a minimum distance of 20 cm from the body.

OVERVIEW

Laserliner-082-086-Thermo-Camera-Connect-
fig-1

  1. 3,2“ TFT color display
  2. Hotkeys
  3. Lens cover
  4. Camera
  5. Infrared camera lens 6 Trigger: Capture
  6. Battery compartment 8 Shaft

Buttons

  • a ON/OFF
  • b Menu navigation
  • c Menu navigation /select digital image, overlay infrared / digital image and infrared image
  • d Open main menu / exit main menu (cancel) / save image
  • e Control menu (confirmation) / do not save image
  • f Control menu (cancel) g Menu navigation / select digital image, overlay infrared / digital image and infrared image
  • h Menu navigation
  • i Micro USB interface

Standard measurement view

  1. The temperature at the center of the image
  2. WLAN active
  3. Set emissivity coefficient
  4. Battery charge indicator
  5. Color palette
  6. Time
  7. Min. temperature
  8. Max. temperature
  9. Temperature at the center of the image
  10. Max. temperature
  11. Thermography image
  12. Min. temperatureLaserliner-082-086-Thermo-Camera-Connect-fig-3 Main menu
  13. Open media gallery
  14. Change color palette
  15. Set emissivity coefficient
  16. Settings Main menu settings
  17. Auto shutdown
  18. Display brightness
  19. Menu Language
  20. Time format
  21. Time settings
  22. Spot (Measuring point)
  23. WLAN connection ON/OFF
  24. Image correction
  25. Software versionLaserliner-082-086-Thermo-Camera-Connect-fig-5

Functions

ON / OFF

Charging the li-ion battery

To charge the Li-ion battery pack, plug the supplied USB cable into the charging socket „i“ and connect it to the USB 2.0 power supply unit. Operation while charging is possible.

Removing/inserting li-ion battery pack

Open battery compartment (7) and remove/insert the Li-ion battery pack. When inserting battery ensure correct polarity.

**Main menu

**

General and measurement-specific settings can be made in the main menu. The menu is controlled with the four buttons (b, c, g, h).Laserliner-082-086
-Thermo-Camera-Connect-fig-9

SettingsLaserliner-082-086-Thermo-Camera-Connect-
fig-10

Settings: Auto shutdown
The device switches off automatically after a set period of inactivity.Laserliner-082-086-Thermo-Camera-Connect-
fig-11

Settings: Display brightnessLaserliner-082-086-Thermo-Camera-Connect-
fig-12

Settings: To set menu language EN / DE / FR / NL / IT / ES / DK / FI / SELaserliner-082-086-Thermo-Camera-Connect-fig-13

Settings: Time formatLaserliner-082-086-Thermo-Camera-Connect-
fig-14

Settings: Set timeLaserliner-082-086-Thermo-Camera-Connect-
fig-15

Settings: Spot (Measuring point)
The temperature is shown in the centre of the image as standard. Two spots can be added. Max: highest temperature, Min: lowest temperature Laserliner-082-086-Thermo-Camera-Connect-fig-16

Settings: WLAN connection
To evaluate the data, the ThermoCamera Connect can be connected via WLAN to a terminal device (desktop PC or mobile phone) with WLAN capabilities. For this purpose first select the required WLAN SSID on the device (MAC:MMMMMM). MMMMMM corresponds to the MAC address.Laserliner-082-086-Thermo-Camera-
Connect-fig-17

The connection with the corresponding SSID is then set up at the terminal device. With any modern browser, the ThermoCamera Connect makes the data available under the IP address 192.168.230.1 Port 80.

Settings: Image correctionLaserliner-082-086-Thermo-Camera-Connect-
fig-19

Settings: VersionLaserliner-082-086-Thermo-Camera-Connect-
fig-20

Emissivity

Before each use, check the settings for infrared measurement and adjust them to the respective measuring situation to ensure accurate measurements. Pay particular attention to the general parameters for the emissivity coefficient.

Emissivity: Emissivity coefficient
The level of infrared emissions given off by everything depends on the specific material and surface. This factor is determined by the emissivity coefficient (0.10 … 1.0). For accurate measurements, it is absolutely essential that the emissivity coefficient is set first. The emissivity coefficient can either be custom set or selected based on the predefined emissivity coefficients from the material list. Laserliner-082-086-Thermo-
Camera-Connect-fig-21Laserliner-082-086-Thermo-Camera-Connect-
fig-22

Emissivity table

reference values with tolerances

Metalle|
---|---
Alloy A3003 oxidiert geraut|

0,20

0,20

| | Inconel oxidiert elektropoliert|

0,83

0,15

| | Stahl galvanisiert oxidiert

stark oxidiert frisch gewalzt

rauhe, ebene Fläche rostig, rot

Blech, nickelbeschichtet Blech, gewalzt Edelstahl, rostfrei

|

0,28

0,80

0,88

0,24

0,96

0,69

0,11

0,56

0,45

|
Aluminium oxidiert poliert|

0,30

0,05

| Kupfer oxidiert Kupferoxid|

0,72

0,78

|
Blei

rau

|

0,40

| Messing poliert oxidiert|

0,30

0,50

|
Chromoxid| 0,81|
Eisen oxidiert mit Rost|

0,75

0,60

| Platin

schwarz

|

0,90

| Zink

oxidiert

|

0,10

|
Stahl

kaltgerollt geschliffene Platte polierte Platte Legierung (8% Nickel,

18% Chrom)

|

0,80

0,50

0,10

0,35

|
Eisen geschmiedet

matt

|

0,90

|
Eisen, Guss nicht oxidiert Schmelze|

0,20

0,25

|
Nicht Metalle|
---|---
Asbest| 0,93| | Kalk| 0,35| | Menschliche Haut| 0,98|
Asphalt| 0,95| Kalksandstein| 0,95| Papier

alle Farben

|

0,96

|
Basalt| 0,70| Kalkstein| 0,98|
Baumwolle| 0,77| Karborundum| 0,90| Porzellan weiß glänzend mit Lasur|

0,73

0,92

|
Beton, Putz, Mörtel| 0,93| Keramik| 0,95|
Eis

glatt

mit starkem Frost

|

0,97

0,98

| Kies| 0,95| Quarzglas| 0,93|
Kohle

nicht oxidiert

|

0,85

| Sand| 0,95|
Erde| 0,94| Schnee| 0,80|
Kunststoff lichtdurchlässig PE, P, PVC|

0,95

0,94

|
Estrich| 0,93| Splitt| 0,95|
Gips| 0,88| Steingut, matt| 0,93|
Gipskartonplatten| 0,95| Kühlkörper

schwarz eloxiert

|

0,98

| Stoff| 0,95|
Glas| 0,90| Tapete (Papier) hell| 0,89|
Lack

matt schwarz hitzebeständig weiß

|

0,97

0,92

0,90

| Teer| 0,82|
Glaswolle| 0,95|
Grafit| 0,75| Teerpapier| 0,92|
Gummi

hart

weich-grau

|

0,94

0,89

| Ton| 0,95|
Laminat| 0,90| Transformatorenlack| 0,94|
Marmor schwarz mattiert gräulich poliert|

0,94

0,93

| Wasser| 0,93|
Holz unbehandelt Buche gehobelt|

0,88

0,94

| Zement| 0,95|
Ziegelstein rot| 0,93|
Mauerwerk| 0,93|

Colour ranges IR image

You can choose from several standard color ranges to represent the measured infrared temperatures. Depending on the color palette, the measured temperatures are adjusted within the current image section and displayed in the respective color space. The bar graph for the respective minimum/ maximum temperatures of the entire image serves as a reference for the corresponding temperature/color mapping.Laserliner-082-086-Thermo-Camera-Connect-
fig-23

Image modes

There are 5 image modes to choose from.

  • A. IR image (IR)
  • B. Digital image (Visible)
  • C. Digital image with IR image overlay (MIX), level 1
  • D. Digital image with IR image overlay (MIX), level 2
  • E. Digital image with IR image overlay (MIX), level 3Laserliner-082-086-Thermo-Camera-Connect-fig-24

Capture image

Using the „Trigger“ button (6), users can take images of any measurement situation for the subsequent documentation.Laserliner-082-086-Thermo-Camera-
Connect-fig-25

Media gallery / to delete the recording

All images recorded with the ThermoCamera Connect can be accessed in the media gallery.Laserliner-082-086-Thermo-Camera-Connect-
fig-26Laserliner-082-086-Thermo-Camera-Connect-
fig-27

The image will be deleted immediately by pressing the MENU button. There are no safety prompts.

Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery pack before storing for longer periods. Store the device in a clean and dry place. Do not touch the lens.

Calibration
The meter needs to be calibrated and tested on a regular basis to ensure it produces accurate measurement results. We recommend carrying out calibration once a year.

EU directives and disposal

This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment. Further safety and supplementary notices at: http://laserliner.com/info?an=AGR.

Technical data

Technische Daten Technische Änderungen vorbehalten. 19W05

Infrarot-Sensor| 220 x 160 Pixel Auflösung,

ungekühltes Microbolometer, 9 Hz, 8-14 μm

Infrarot-Optik| Hochwertiges Infrarotobjektiv, 27° x 35° Sichtfeld (FOV),

Fokus fixiert, Arbeitsbereich: 0,5 m … 20 m

Thermische Empfindlichkeit| 0,07°C @ 30°C
Genauigkeit| ± 2°C oder ± 2% vom Messwert
Messbereich| -20°C … 350°C
Display| 3,2“ TFT-Farbdisplay
Bildmodi| Infrarotbild, Digitalbild, MIX-Bild
Digitalkamera| Auflösung: 640 x 480 Pixel
Format| JPEG Format
Speicherfunktion| integrierter SD-Speicher (mehr als 20.000 Bilder)
Schnittstelle| WLAN
Anschlüsse| Micro-USB Ladefunktion
Emissionsgrad| 0,01 – 1,0 einstellbar
Schutzart| IP54
Arbeitsbedingungen| 0°C … 45°C, Luftfeuchtigkeit max. 20 … 85% rH, nicht kondensierend, Arbeitshöhe max. 2000 m über NN (Normalnull)
Lagerbedingungen| -20°C … 60°C, Luftfeuchtigkeit max. 85% rH
Betriebsdaten Funkmodul| WLAN-Standard| IEEE 802.11 b/g/n
Frequenzband| 2.400 – 2.4835 GHz (IEEE 802.11 b/g/n)
Funkkanäle| Kanal 9
Sendeleistung| 17 dBm max.
Übertragungsrate| IEEE 802.11 b bis 11 Mbps

IEEE 802.11 g/n bis 54 Mbps (bei 15 ± 2 dBm)

Sicherheit| offen
Lokaler Server Modus| IP-Adresse 192.168.230.1; HTTP; kein DHCP
Port| 80
Automatische Abschaltung| einstellbar: 5 Minuten / 20 Minuten / keine autom. Abschaltung
Stromversorgung| Li-Ion Akkupack 3,5V – 4,2V / 2000 mAh Micro-USB 4,75V – 5,50V
Ladezeit| ca. 3 – 4 Std.
Betriebsdauer| ca. 2 – 3 Std. (je nach Art der Nutzung)
Abmessungen (B x H x T)| 105 x 223 x 90 mm
Gewicht| 389 g (inkl. Akkupack)

Laserliner-082-086-Thermo-Camera-Connect-fig-28

SERVICE

Umarex GmbH & Co. KG

Laserliner

  • Möhnestraße 149, 59755 Arnsberg, Germany
  • Tel.: +49 2932 638-300,
  • Fax: +49 2932 638-333
  • info@laserliner.com.

Umarex GmbH & Co. KG

  • Donnerfeld 2 59757 Arnsberg, Germany
  • Tel.: +49 2932 638-300,
  • Fax: -333
  • Web site: www.laserliner.com.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals