Viking VK150 Parco UV STAGE LIGHTING User Manual

June 5, 2024
VIKING

Viking VK150 Parco UV STAGE LIGHTING

Specifications and Features

  • LEDs: 100W UV LED
  • Power Consumption: 150W
  • Refresh Rate: 900Hz~10000Hz
  • Dimmer Curve: 4 dimmer curve mode
  • DMX Channels Mode: 1CH,2CH,3CH,5CH
  • Control Protocol: DMX
  • Support RDM
  • Color: White and black
  • Each LED can pixel control.
  • Built-in dynamic auto run effect.
  • Touch OLED display
  • XLR Connectors: Seetronic IP65 3pin&5pin XLR Connector
  • Powercon True1 in/out
  • Barndoor optional
  • Work mode: Auto, DMX, Master/Slaver
  • With handle and safe
  • Power input: 110~240V,50/60Hz
  • Size: 307x234x247mm
  • Net Weight: 3.5KG

Product View

Product Description

  • 1: Menu
  • 2: Pressure valve
  • 3:DMX IN/ DMX OUT
  • 4:POWER IN/POWER OUT

VK150 Parco UV

1 CH 2CH 3CH 5CH VALUES FUNCTION

1

|

1

|

1

|

1

| 000-255| MASTER DIMMER 0%-100%
|

2

|

2

|

2

| 000-255| DIMMER FINE 0%-100%
|

3

|

3

| | SHUTTER & STROBING
000-031| LED Off
032-063| LED On
064-095| Strobing Slow – Fast
096-127| LED On
128-159| Pulse Strobing
160-191| LED On
192-223| Random Strobing Slow – Fast
224-255| LED On
|

4

| | DIMMER MODES
000-020| Standard
021-040| Stage
041-060| TV
061-080| Architectural
081-100| Theatre
101-120| Stage 2
| DIMMER DELAY TIME
121| 0.1Sec.
122| 0.2Sec.
123| 0.3Sec.
124| 0.4Sec.
125| 0.5Sec.
126| 0.6Sec.
127| 0.7Sec.
128| 0.8Sec.
129| 0.9Sec.
130| 1.0Sec.
131| 1.5Sec.
132| 2.0Sec.
133| 3.0Sec.
134| 4.0Sec.
135| 5.0Sec.
136| 6.0Sec.
137| 7.0Sec.
138| 8.0Sec.
| | | | 139| 9.0Sec.
---|---|---|---|---|---
140| 10Sec.
141-255| Default to Unit Setting

5

| | REFRESH RATE
000-015| Default to Unit Setting
016-035| 900HZ
036-055| 1000HZ
056-075| 1100HZ
076-095| 1200HZ
096-115| 1300HZ
116-135| 1400HZ
136-155| 1500HZ
156-175| 2500HZ
176-195| 4000HZ
196-215| 5000HZ
216-235| 6000HZ
236-255| 10000HZ

SYSTEM MENU

The fixture includes an easy to navigate system menu control panel display where all necessary settings and adjustments are made. (See image below) During normal operation, pressing the MENU button once will access the fixture’s main menu. Once in the main menu, you can navigate through the different menus with the UP, DOWN, and MENU buttons. When you reach a field that requires adjusting, press the ENTER button to access that field and use the UP and DOWN buttons to adjust the field. Pressing the ENTER button once more to confirm your setting. You may exit the menu’s
at any time without making any adjustments by pressing the MENU button. If there are no changes/ adjustments made within 10 seconds, the unit will revert back to the setting made under “No DMX State”.

DMX

Address

|

001-512

|

0~255

0~255

0.5s~30s

---|---|---

DMX Mode

| 1CH
2CH
3CH
5CH

Stand Alone

| Dimmer
Strobe
Fader

Settings

| Display Reverse| On
Off
Display Backlight| On
Off

DMX Fail

| Hold
Blackout
ManualMode

Dimmer Curve

| Standard
Stage
TV
Architectural
Theatre
Stage2
Dimmer Speed| 0.1-0.9s ~ 1-10s
|

AutoLock

|

On

Off

Fan Mode

| Smart
Silent
Max

PWM Rate

| 900Hz
1000Hz
1100Hz
1200Hz
1300Hz

Push UP and DOWN button together more than 5 seconds to unlock the display

| | 1400Hz
---|---|---
1500Hz
2500Hz
4000Hz
5000Hz
6000Hz
10000Hz
Service| Reset
Calibration

System Info

| Firmwre| V1.0
Operation Hours| xxxHrs
Temperature| xxx°C
RDM| RDM ID

Passcode = 50

SET ADDRESS – In this menu you can find and set your desired DMX address.
DMX CHANNEL MODE – In this menu you can find and set your desired DMX channel mode.
NO DMX STATUS – This menu setting is used as a precaution mode in case the DMX signal is lost or interrupted. The operating mode chosen in this menu is the running mode the fixture will go into when the DMX signal is lost. Listed below are the 3 modes.

  • Hold Last – This setting will have the fixture stay in the last DMX setup
  • Blackout – This setting will have the fixture automatically go into standby mode.
  • Manual – This setting will go into the current manual control set up. See MANUAL CONTROL.

DIM MODES – In this menu you are able to select your desired dimmer mode and adjust the dimming speed time.
LED REFRESH RATE – In this menu you are able to select your desired LED refresh rate.
DISPLAY – In this menu you are able to activate/deactivate the display blackout and activate/deactivate the display lock.
SERVICE – In this menu you are able to access and adjust/change: the calibration (effect adjust) and restore the factory settings.
MANUAL CONTROL – This menu is for manual testing and manual control. The dimmer and strobe can be tested/adjusted. The fixture must be set to “Manual” under “No DMX State”.
SOFTWARE VERSION – The current software version is displayed.

Dimmer Curve Chart

Viking VK150 Parco UV STAGE LIGHTING-4


Dimming Curve Ramp Effect

| 0 sec Fade Time                                                      1 sec Fade Time
---|---
| 255| 255



0



0

|
| Rise Time (ms)| Down Time (ms)| Rise Time (ms)| Down Time (ms)
Standard (default)| 0| 0| 0| 0
Stage| 780| 1100| 1540| 1660
TV| 1180| 1520| 1860| 1940
Architectural| 1380| 1730| 2040| 2120
Theatre| 1580| 1940| 2230| 2280
Stage 2| 0| 1100| 0| 1660

Documents / Resources

| Viking VK150 Parco UV STAGE LIGHTING [pdf] User Manual
VK150 Parco UV STAGE LIGHTING, VK150 Parco UV, Parco UV STAGE LIGHTING, STAGE LIGHTING, 150w
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VIKING User Manuals

Related Manuals