aube technologies TH104PLUS Programmable Thermostat Owner’s Manual

June 5, 2024
aube technologies

aube technologies TH104PLUS Programmable Thermostat

About your new thermostat

This thermostat is designed to control an electric heating system such as a
baseboard heater, a radiant ceiling, a convector or a fan-forced heater.
The thermostat CANNOT be used with:

  • a resistive load under 0.83 A
  • a resistive load over 14.6 A
  • a system driven by a contactor or a relay (inductive load)
  • a central heating system

SUPPLIED PARTS

  • One (1) thermostat
  • Two (2) 6-32 mounting screws
  • Two (2) solderless connectors

Do you need assistance?
We are here to help.
Call 1-800-831-2823.

Controls

The screen is backlit for 12 seconds when you press any button.

Display

To display the set temperature (setpoint), press the Up or Down button once. The thermostat will display the setpoint instead of the clock for 5 seconds.

Installation guidelines

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK.

  • All cables and connections must comply with local electrical codes.
  • This thermostat has tinned copper wires for line and load connections. Special CO/ALR solderless connectors must be used if these wires will be connected to aluminium conductors.
  • Install the thermostat onto an electrical box.
  • Install the thermostat about 1.5 m (5’) high, on an inside wall facing the heater.
  • Avoid locations where there are air drafts (such as the top of a staircase or an air outlet), dead air spots (such as behind a door), or direct sunlight.
  • Do not install the thermostat on a wall that conceals chimney or stove pipes.
  • The thermostat wires are not polarized; either wire can be connected to the load or to the power supply

Wiring

Connect the thermostat wires to the power and to the load using solderless connectors for copper wires.

Thermostat mounting

Push the excess wires back inside the electrical box.
Secure the thermostat to the electrical box using the provided screws. Insert the screws through either the right or left pair of mounting holes on the thermostat.
NOTE: If there is a protective film or sticker on the thermostat’s screen, peel it off.
Apply power to the heating system. Verify the installation by checking that the heater can be turned on by raising the setpoint using the Up button and off by lowering the setpoint using the
Down button.
WARNING:
Keep the thermostat’s air vents clean and free from obstructions.

Clock and day setting

  1. Press the Day button to set the day.
  2. Use the Hour and Min buttons to set the clock.
  3. Press the  ENTER button to exit.

Automatic mode

In Automatic mode, the thermostat adjusts its temperature setpoint according to the period of the day. To place the thermostat in this mode, press the Mode button until Auto appears on the screen. The current period name also appears (unless the thermostat has not been programmed with a schedule). You can program up to 4 periods (Wake, Leave, Return or Sleep) in a day. You can set 2 different programs: one for the weekdays (Monday to Friday) and another one for the weekend (Saturday and Sunday).

The thermostat uses the following default schedule

  Monday to Friday Saturday & Sunday
Period Start Time Temperature

Temperature
Wake| 6:00| 21.0°C (70°F)| 6:00| 21.0°C (70°F)
Leave| 8:00| 16.5°C (62°F)| –:–| – –
Return| 18:00| 21.0°C (70°F)| –:–| – –
Sleep| 22:00| 16.5°C (62°F)| 22:00| 16.5°C (62°F)

Temporary Override
You can temporarily modify the setpoint temperature while the thermostat is in Automatic mode using the Up or Down button. The new setpoint will be used until the beginning of the next period. During the override, Auto flashes on the screen.
You can cancel the override by pressing the ENTER button.

To modify the schedule:

  1. Press the Pgm button. Each time you press the Pgm button, the thermostat displays one of the periods of the schedule in the following order:
    Weekdays (MO TU WE TH FR)| Weekend (SA SU)
    ---|---
    1| 2| 3| 4| 1| 2| 3| 4

  2. Press the Hour and Min buttons to set the start time of the displayed period.
    NOTE: To cancel the period, press the Mode button. Instead of displaying the start time of the period, the thermostat will display –:–. During operation, the thermostat will skip over that period.

  3. Press the Up or Down button to set the temperature.

  4. To set another period, press the Pgm button and repeat steps 2 and 3.

  5. Press the button to return to normal display.

Manual (Man) mode

To place the thermostat in Manual mode, press the Mode button until Man appears on the screen. In this mode, any modification to the temperature setpoint must be done manually. To set the temperature, press the Up or Down button. The default setting is 21.0°C (70°F).

Away mode

To place the thermostat in Away mode, press the Mode button until Away appears on the screen. This mode is a quick way to lower the temperature to a predetermined setting before you go away for an extended length of time. The temperature is 15.0°C (59°F) by default and can be modified using the setup menu (see page 11).

Standby mode

To disable heating, press the Mode button until Standby appears on the screen. In this mode, the setpoint temperature cannot be displayed or modified. For frost protection, heating will turn on only to prevent the room temperature from dropping below 5°C (41°F).

Advanced settings

  1. Press the Pgm button for 3 seconds.

  2. To display the next parameter, press the Pgm button.

  3. To modify the displayed parameter, press the Up or Down button.

  4. To exit the menu, press the ENTER button or do not press any button for 1 minute.

  5. Fan
    Place at Yes if you have a fan-forced heater (to prevent premature burnout of the motor). Leave at No for better temperature regulation if you do not have a fan-forced heater.

  6. Away temperature
    Set the temperature you wish to use when the thermostat is in Away mode (see page 10).

  7. Daylight Saving Time
    When the Daylight Saving Time function is enabled (On), the thermostat automatically switches to Daylight Saving Time on the second Sunday of March and to normal time on the first Sunday of November.

  8. Year, Month, Day
    These parameters are available only if the Daylight Saving Time function is enabled (On).

  9. Early Start
    Early Start is used in Automatic mode only. When Early Start is enabled (On), the thermostat determines when to start heating so the desired temperature is attained at the beginning of Wake and Return periods. When Early Start is disabled (Off), heating starts only at the beginning of Wake and Return periods; thus there is a delay before you reach the desired temperature.

  10. Keypad lock
    The settings are locked. The temperature adjustment buttons only allow you to view the temperature setpoint.

In case of difficulty

PROBLEM SOLUTIONS
Thermostat is hot. This condition is normal. Ensure that the heater capac-ity

does not exceed the thermostat’s maximum load.


Wrong temperature is displayed.

| Correct it if any of the following situations exists:

•   The thermostat is exposed to an air draft.

•   The thermostat is located near or above a  heat  source  such as a light dimmer.

Wrong time is displayed.| The thermostat was without power for more than 5 hours. See page 7 to set time.
Temperature does not change according to the programmed schedule.| Check that the thermostat is in Automatic mode. Check the schedule and clock settings. If the thermo-stat is configured in 12-hour format, ensure that PM appears on the screen when afternoon times are dis-played.
LP appears on the screen or the screen is blank despite there is no power outage.| The thermal circuit breaker in the heater is opened. This can happen if the heater is obstructed by furniture or curtain and has overheated, or if the thermal circuit breaker is defective or too sensitive.
The settings cannot be changed.| The settings are locked (see page 13).
LO is displayed.| The measured temperature is below the display range. Heating is activated.
HI is displayed.| The measured temperature is above the display range.
E1, E2 is displayed.| The thermostat performance is reduced due to a sensor error.

Please contact technical support for more information.

Resetting the thermostat (default settings)

WARNING: All parameters, except the clock (time and day), return to their default settings when the thermostat is reset.

  1. Press the Mode button until Standby appears on the screen.
  2. Press the ENTER button for 6 seconds.
  3. The thermostat will display rSt (reset) for 2 seconds to indicate it is reset and will then return to normal display.

Power outage

During a power outage, LP (low power) appears for the first minute. Then the screen becomes blank. The settings are stored in memory. After the initial installation, product must be connected to power for a minimum of two hours to enable the power outage feature. However, if the power failure exceeds 4 hours, the thermostat’s clock must be readjusted and, if you are using the automatic Daylight Saving Time changeover function, it must be re-enabled. When power returns, the thermostat will return to the mode of operation active prior to the power failure

Specifications

  • Supply: 120/240 V AC, 60 Hz

  • Minimum load: 0.83 A (resistive only)
    200 W @ 240 V AC
    100 W @ 120 V AC

  • Maximum load: 14.6 A (resistive only)
    3500 W @ 240 V AC
    1750 W @ 120 V AC

  • Display range: 0°C to 50.0°C (32°F to 99°F)

  • Setpoint range: 5.0°C to 30.0°C (41°F to 86°F)

  • Resolution: 0.5°C (1°F)

  • Storage temperature: -20°C to 50°C (-4°F to 120°F)

  • ICES-003 Class B Notice: This Class B digital apparatus complies with Canadian ICES-003.

3-year limited warranty

Resideo warrants this product, excluding battery, to be free from defects in workmanship or materials, under normal use and service, for a period of three (3) years from the date of first purchase by the original purchaser. If at any time during the warranty period the product is determined to be defective due to workmanship or materials, Resideo shall repair or replace it (at Resideo’s option). If the product is defective,

  1. return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or
  2. call Resideo Customer Care at 1-800-831-2823. Customer Care will make the determination whether the product should be returned to the following address: Resideo Return Goods, Dock 4 MN10-3860, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Resideo that the defect was caused by damage which occurred while the productC was in the possession of a consumer.
Resideo’s sole responsibility shall be to repair or replace the product within the terms stated above.

RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE THREE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-831-2823.

Customer Assistance

If you have any questions about the product, contact us at:
Tel: 1-800-831-2823
CAUTION: ELECTRONIC WASTE NOTICE
The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent negative consequences for the environment and human health.
FCC statement available: https://customer.resideo.com/en- US/support/residential/codes-and-standards/FCC15105/Pages/default.aspx

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals