aube technologies TH110A-DP-P Thermostat User Manual
- June 9, 2024
- aube technologies
Table of Contents
MODEL TH110A-DP-P
SUMMARY
-
OPTIONS SELECTION
At the back of the thermostat, there are 3 selection switches to set your preferences.
Temperature in °C or °F, time in 12 or 24 hours and Early Start function. -
TO SET TIME AND DAY
Press on DAY, HOUR and MIN buttons to adjust time and day. -
TO RECORD THE (COMFORT) SETPOINT TEMPERATURE
Select chosen setpoint temperature by using button. Press on button (app. 3 seconds) until icon appears on display. -
TO RECORD THE (ECONOMY) SETPOINT TEMPERATURE Select chosen setpoint temperature by using button.
Press on button (app. 3 seconds) until icon appears on display . -
TO RECORD THE (VACATION) SETPOINT TEMPERATURE
To program the Vacation temperature, select the desired degree using buttons and press on the and buttons simultaneously until the icon is displayed (app. 3 seconds). -
OPERATING MODES
To select an operating mode, use MODE button. -
AUTO: Runs the program. shows temperature setting and can override temporarily your programming up to the next program.
MAN: Maintains the selected temperature. changes the temperature setting.
INSTALLATION
NOTE: The “Problems and Solutions” section at the end of this user’s
guide will help you to correct your problems during the installation.
This thermostat has been designed to operate with any installation which has a
RESISTIVE load not exceeding 4000 W (16.67 A) @ 240 VAC such as electric
baseboards, radiant ceilings and floors, electric con vectors, etc. It is not
compatible with a low voltage controller used by a central heating system.
Electricians or experienced technicians should install the thermostat.
This thermostat is designed to be used with a self-protected heating system
equipped with thermal cut off and circuit breaker.
More user manuals on ManualsBase.com
PARTS INCLUDED
- One (1) TH110A-DP-P (240 VAC) thermostat
- Two (2) 6-32 screws
- Four (4) solderless connectors (for copper wire)
TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Keep air vents of the thermostat clean and free from obstructions.
NOTE: All cables and connections must conform to the local electrical
code.
WARNING: Special CO/ALR solderless connectors must be used when
connecting with aluminum conductors.
Power-up
Set the On/Off switch to On.
When power is applied for the first time, the display must show the time
00:00, the room temperature and the Manual mode icon ( ).
Other information might show up on the display if installation is defective or
does not comply with the instructions.
NOTE: The On/Off switch set to Off will place the thermostat in sleep
mode. Ideal for summertime.
OPERATING MODES
The TH110A-DP-P has two (2) operating modes.
MANUAL ( )
This mode allows you to maintain a constant temperature in the room.
- To activate this mode, press on Mode button to display the icon .
- Set the desired temperature using the buttons or select the pre-programmed or or settings.
(To select the setting, press on and simultaneously.)
AUTOMATIC ( )
This mode executes your own programming.
To activate this mode, press on Mode button to display the icon .
The or icon indicates which temperature setting is used. Also, the icon of the
program number will be shown.
Memory back-up
In the event of a power failure, an internal circuit will maintain the
programming and the time. But only the time could have to be set if power
failure is more than 2 hours.
Early Start function
The thermostat is providing a built-in function enabling it to calculate the
optimum time to start the heating system to achieve the desired temperature
setting at the programmed time. This function could start the heating system
as early as 6 hours prior to the programmed time. To enable this function, set
the switch E.S. to “ON” at the back of the thermostat.
PROGRAMMING
Programming the time and day
- Set the time using the Hour and Min buttons.
- Set the day using the Day button.
Programming the Comfort, Economy and Vacation settings
The Comfort , Economy and Vacation settings respectively represent the
temperatures that you wish to have during the day , at night or while you are
away at work , or while you are away for an extended period .
To program your settings
a) To program the Comfort temperature, select the desired degree using the
buttons and press the button until the icon is displayed (app. 3 seconds).
b) To program the Economy temperature, select the desired degree using the
buttons and press the button until the icon is displayed (app. 3 seconds).
c) To program the Vacation temperature, select the desired degree using the
buttons and press on the and buttons simultaneously until the icon is
displayed (app. 3 seconds).
d) Press the Mode button to exit this function and return to the normal
operating mode.
Schedule programming
The TH110A-DP-P allows 4 setting changes for each day of the week. There are
no pre-set programs.The programs are tailored to perfectly adapt to your life
style. The principle is very simple. For each day, enter the time at which you
wake up (P1), the time you leave for work (P2), the time you arrive back home
(P3) and the time you go to bed (P4).
Program | Mode | Time |
---|---|---|
1 | Wake-up time | |
2 | Leaving time | |
3 | Return time | |
4 | Bed time |
For savings to be obtained, you must lower the temperature for a period of 2
to 3 times the delay required to bring the temperature back to your comfort
level.
Example : If your system takes one hour to go from your saving temperature
level to your comfort temperature Ievel, it is useless to lower the
temperature for a period less than 2 to 3 hours.
a) To program your schedule
- Press on PGM button to access the programming mode.
- Press on Day button to select the day to be programmed. You can select all days of the week by pressing on Day button for 3 seconds.
- Press on PGM button to select program 1, 2, 3 or 4.
- Press on Hour and Min buttons to program the time.
- When you have completed your programming, press on Mode button to exit this function.
b) To erase a program :
Select the program using PGM and Day buttons, and press on Clear button. The
time field displays –:– when the program is inactive.
c) Example 1 : Comfort period from 7:00 AM to 10:30 PM
Economy period from 10:30 PM to 7:00 AM Identical schedule for all days of the
week.
- Press on PGM button to access the programming mode.
- Press on Day button 3 seconds to select every day of the week.
- Press on Hour button to enter 7:00 AM, Prog. 1 ( ).
- Press on PGM button again to select Prog. 2 ( ), and press on Hour and Min buttons to enter 10:30 PM.
- Press on Mode button to exit this function.
d) Example 2 : Comfort period: Monday to Friday from 6:15 AM to 8:15 AM and from 5:00 PM to 10:00 PM. Saturday & Sunday from 7:30 AM to 11:00 PM.
Schedule/Day MON. TUES. WED. THU. FRI. SAT. SUN.
PROG. 1| 6:15 AM| 6:15 AM| 6:15 AM| 6:15 AM| 6:15 AM| 7:30 AM| 7:30 AM
PROG. 2| 8:15 AM| 8:15 AM| 8:15 AM| 8:15 AM| 8:15 AM| |
PROG. 3| 5PM| 5PM| 5PM| 5PM| 5PM| —| —
PROG. 4| 10 PM| 10 PM| 10 PM| 10 PM| 10 PM| 11 PM| 11 PM
NOTE:
It is faster to program the same schedule for every day and then modify the
exception days.
-
Press on PGM button to access the programming mode.
-
Press on Day button 3 seconds to select every day of the week.
-
Press on Hour and Min buttons to enter 6:15 AM, Prog. 1 ( ).
-
Press on PGM button to select Prog. 2 ( ) and Hour and Min buttons to enter 8:15 AM.
-
Repeat step 4 to enter Prog. 3 (5:00 PM) and Prog. 4 (10:00 PM).
More user manuals on ManualsBase.com
NOTE: When making modifications, make sure you are in the right program.
To modify the Saturday and Sunday schedules: -
Press on Day button until SA or SU is displayed.
-
Press on PGM button to select Prog. 1 ( ) and Hour and Min buttons to enter 7:30 AM.
-
Press on PGM button to select Prog. 2 ( ) and then Clear button to erase it.
-
Press on PGM button to select Prog. 3 ( ) and then Clear button to erase it.
-
Press on PGM button to select Prog. 4 ( ) and then Hour and Min buttons to enter 11:00 PM.
-
Press on Mode button to exit this function.
Temporary or permanent temperature bypass
This operation allows you to temporarily modify the room temperature while you
are in the Automatic mode. Simply press on button to select the desired
temperature, or the or button to select the Comfort or Econo settings you have
programmed.This temperature will be maintained until the beginning of the next
programmed schedule.
You can also switch to the Vacation setting for a prolonged absence by
pressing on and at the same time.The display will show icon. In that case, the
derogation is permanent. To return to the normal operating mode, press on Mode
button.
If you wish to immediately return to the programmed settings, press on Mode
button twice.
CHARACTERISTICS
• Model: | TH110A-DP-P (240 VAC) |
---|---|
• Supply: | 240 VAC, 50/60 Hz |
• Load: | 16.67 A maximum (resistive only) |
• Power: | 4000 watts (NI) @ 240 VAC |
• Approvals: | CSA / UL |
• Display range: | 0 to 60 °C (32 to 140 °F) |
• Setting range: | 5 to 30 °C (40 to 85 °F) |
• Comfort default setting: | 20 °C (68 °F) |
• Econo default setting: | 18 °C (64 °F) |
• Vacation default setting: | 10 °C (50 °F) |
• Storage: | -20 to 50 °C (-4 to 120 °F) |
WARRANTY
AUBE TECHNOLOGIES INC. ONE (1) YEAR LIMITED WARRANTY
This product is warranted against material defects and workmanship in normal
use for a period of one year, from the date of the original purchase from
authorized dealers. During this period, AUBE technologies inc. will repair or
replace the product with a new or of equivalent quality at AUBE’S option,
without charge, any product proven defective in normal use.
Warranty does not cover transportation costs. Nor does it cover a product
subjected to misuse or accidental damage. This warranty does not cover the
cost of installation, removal or reinstallation.
This limited warranty is in lieu of all other warranties, obligations or
liabilities expressed or implied by the company. In no event shall AUBE
technologies inc.
be liable for consequential or incidental damages resulting from installation
of this product. Some states or provinces do not allow limitations on how long
an implied warranty lasts, or the exclusion or limitation of incidental or
consequential damages, so the above exclusions or limitations may not apply to
you. This warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
The defective product and the original sale receipt must be returned to the
original dealer or shipped pre-paid, insured and addressed to: Aube
technologies inc., 705 Montrichard, Iberville (Quebec), Canada, J2X 5K8
www.aubetech.com
**service@aubetech.com**
If you have any questions concerning the installation or programming of this
product, please call our technical assistance at
450-358-4600 for the Montreal area or
1-800-831-AUBE for outside area, Monday to Friday between 8:30 AM and 5:00 PM
Eastern time.
PROBLEMS AND SOLUTIONS
PROBLEMS | CAUSES | SOL |
---|---|---|
No display | • Circuit breaker is open |
• Power failure
• The thermostat switch is in Off position| • Check 240 VAC presence at the
thermostat
• Put the switch in On position
The thermostat is loosing the time but not the programming| • Power failure
more than 2 hours|
Room temperature shown is wrong| • A draft is nearby the thermostat| •
Eliminate the draft
Programs do not change as you want| • Incorrect programming hours
• Wrong programming mode selected| • Check actual time in AM & PM as well as
program times (AM is not displayed)
• Make sure operating mode is set to AUTO
References
- User manuals for your devices. - ManualsBase.com - Solve your problem
- User manuals for your devices. - ManualsBase.com - Solve your problem