SEALEY PEH5001 5000W Industrial PTC Fan Heater Instruction Manual
- June 5, 2024
- SEALEY
Table of Contents
5000W INDUSTRIAL PTC FAN HEATER – 415V 3PH
MODEL NO: PEH5001
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to Instructions Electrical Shock Hazard
Hot Surfaces Do not Cover
THIS PRODUCT IS ONLY SUITABLE FOR WELL INSULATED SPACES OR OCCASIONAL USE
1. SAFETY
1.1. ELECTRICAL SAFETY
WARNING! ELECTRICAL INSTALLATION OF THE FAN HEATER TO A 3-PHASE 415VOLT SUPPLY MUST ONLY BE CARRIED OUT BY A QUALIFIED ELECTRICIAN.
1.1.1. Make sure the power supply cable is correctly connected to the earth.
It is the user’s responsibility to read, understand and comply with the
following:
1.1.2. You must check all electrical equipment and appliances to ensure they
are safe before using. You must inspect power supply leads, plugs and all
electrical connections for wear and damage. You must ensure the risk of
electric shock is minimised by the installation of appropriate safety devices.
An RCCB (Residual Current Circuit Breaker) should be incorporated in the main
distribution board.
1.1.3. You must also read and understand the following instructions
concerning electrical safety.
The Electricity At Work Act 1989 requires all portable electrical
appliances, if used on business premises, to be tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
The Health & Safety at Work Act 1974 makes owners of electrical appliances
responsible for the safe condition of the appliance and the safety of the
appliance operator. If in any doubt about electrical safety, contact a
qualified electrician.
1.1.4. Ensure insulation on all cables and the product itself is safe before
connecting to mains power supply.
1.1.5. Ensure that cables are always protected against short circuit and
overload.
1.1.6. Regularly inspect power supply, leads, plugs and all electrical
connections for wear and damage, especially power connections, to ensure that
none are loose.
1.1.7. Important: Ensure the voltage marked on the product is the same as
the electrical power supply to be used. A three phase plug must be fitted to
this machine.
DO NOT pull the powered appliance by the power cable.
DO NOT pull power plugs from sockets by the power cable.
DO NOT use worn or damage leads, plugs or connections. Immediately
replace or have repaired by a qualified electrician.
1.1.8. This product must be fitted with a 3-phase plug according to the
diagram, and will require a minimum supply of, 16Amps per phase.
1.1.9. You must contact a qualified electrician to ensure an
appropriately fused supply is available. Connect GREEN/YELLOW wire to earth
(E) terminal.
Connect the live wires to live 1, 2 and 3.
1.1.10. When completed, check that there are no bare wires, that all wires
have been connected correctly, that the cable external insulation extends
beyond the cable restraint and that the restraint is tight.
1.2. GENERAL
WARNING! Disconnect the heater from the mains power supply before
carrying out any servicing or maintenance.
Maintain the heater in good order and clean condition for best and
safest performance. Replace or repair damage parts.
Locate heater in a suitable work area and keep area clean, tidy and free
from unrelated materials. Ensure there is adequate lighting and keep the
immediate area in front of the outlet grille clear.
Allow the unit to cool before storage. When not in use, disconnect from
the mains power supply and store in a safe, cool, dry, childproof area.
Only use the heater standing in the upright position on a level surface.
DO NOT use the heater where there are flammable liquids, solids or gases
such as petrol, solvents, aerosols etc, or where heat sensitive materials may
be stored.
DO NOT place the heater near items that may be damaged by heat, allow at
least 2mtr clearance in front of the heater.
DO NOT allow the heater to get wet as this may cause an electric shock,
causing damage to the heater and possible personal injury.
DO NOT let power lead hang over an edge (i.e. table), or touch a hot
surface, lie in the beam of heat, or run under a carpet.
DO NOT use in bathroom, shower room, or in any wet or damp environments
or where there is high condensation.
DO NOT operate the heater when you are tired or under the influence of
alcohol, drugs or intoxicating medication.
DO NOT insert or allow objects to enter any openings of heater as this
may cause an electric shock, fire or damage to heater.
DO NOT use heater if the power cord, plug or the heater is damaged, or if
the heater has become wet.
DO NOT use the heater for any purpose other than for which it is
designed.
DO NOT use a timer or other remote device to operate the heater.
DO NOT allow children to touch or to operate the heater.
DO NOT site the heater below an electrical socket outlet.
DO NOT use the heater without the grille fitted.
DO NOT use the heater out of doors. These heaters are designed for indoor
use only.
DO NOT cover heater when in use, and do not obstruct the air inlet and
outlet grilles.
DO NOT place heater too close to yourself or any object, allow the air to
circulate freely.
DO NOT touch the outlet grille of the heater during and immediately after
use as it will be hot.
2. INTRODUCTION
Industrial fan heater with PTC heat conducting ceramic elements to achieve an instant, totally dry heat with no condensation, no gas, no fumes and no smell. Ambient room thermostat maintains temperature at a pre-set level, Ideal for industrial applications with two heat settings or fan only. Supplied with power cable.
3. SPECIFICATIONS
Model No: ………………………………. PE5001
Power Settings: ……………………………….. 3300/5000W
Supply: ……………………………………………. 415V
Dimensions (WxDxH): ………………….. 300x235x343mm
Weight: ……………………………………………. 4.2kg
4. HEATER OPERATION
4.1. Place the heater on a level floor in the area you require to heat.
Allow a minimum of 2mtr between the heater and adjacent objects.
4.2. Plug the heater into the mains supply and select the required output
by using the rotary switch on the top of the heater. The setting are
4.3. fan only, half heat, full heat. The thermostat is operated by the
second nob.
4.4. To switch the unit off, select “0”. Allow the unit to cool before
handling or storage.
WARNING! DO NOT touch the top of the heater when in use as it becomes
hot.
WARNING! Always allow elements to cool before moving the units. Use only
on a smooth even surface.
5. MAINTENANCE
WARNING! Before attempting any maintenance ensure the unit is unpluged
from the mains power supply, it is cool and on level ground.
DO NOT use the heater with out the grills fitted.
5.1. Sealey recommend that repairs are carried out by a qualified electrician.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the
EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories and packaging should be sorted, taken to a recycling centre and
disposed of in a manner which is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
Note: It is our policy to continually improve products and as such we
reserve the right to alter data, specifications and component parts without
prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is
required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
Information requirements for electric local space heaters
© Jack Sealey Limited Original Language Version
PEH5001 / | Issue 3 (ERP) 30/07/19
Get In Touch
Call: 0845 6880112
Email: info@adremit.co.uk
Our Address
Puravent, Adremit Limited, Unit 5a, Commercial Yard,
Settle, North Yorkshire, BD24 9RH
Read User Manual Online (PDF format)