SAFETY INSTRUCTIONS

  • Thank you for purchasing this cooker hood. Please read the instruction manual carefully before you use the cooker hood, and keep it in a safe place.
  • The installation work must be carried out by a qualified electrician or competent person. Before you use the cooker hood, make sure that the voltage (V) and the frequency (Hz) indicated on the cooker hood are exactly the same as the voltage (V) and the frequency (Hz) in your home.
  • The manufacturer and the agent will not bear any responsibility for the damage caused by inappropriate installation and usage.
  • Never let children operate the cooker hood.
  • The cooker hood is for home use only. It is not suitable for barbecues, Roast shop and commercial purposes.
  • The cooker hood and its filter mesh should be cleaned regularly in order to keep it in good working order.
  • Before cleaning, switch the power off at the main supply.
  • Clean the cooker hood according to the instruction manual and keep the cooker hood from the danger of burning.
  • Prohibit putting the cooker hood by fire.
  • If there is any fault with the appliance, please call the service department to request a service engineer.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • The instructions shall state the substance of the following: there shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
  • Do not flambé under the range hood. Accessible parts may become hot when used with cooking appliances.

Important Hints on Installation

  • The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
  • Regulations concerning the discharge of air have to be fulfilled.

Important notes about the extraction mode

WARNING
Risk of poisoning from exhaust gases sucked back. Never operate the device in extraction mode simultaneously with an open flue appliance when there is not adequate airflow guaranteed.

Open flue combustion equipment (for example, gas, oil, wood or coal-fi red heaters, tankless water heaters, water heaters) pulls combustion air from the room and runs it through an exhaust pipe or chimney to the outside. In the extraction mode, indoor air is removed from the kitchen and the adjacent rooms – without sufficient air intake this creates a vacuum. Toxic gases from the chimney or extraction flue can thereby be sucked back into the living spaces.

  • Always ensure that a sufficient supply of fresh air is guaranteed and that the air can circulate.
  • An air supply / extractor box alone does not ensure compliance with the limit value.

Safe operation is only possible when the negative pressure in the room where the appliance is located does not exceed 4 Pa (0.04 mbar). This can be achieved when the air required for combustion can flow through openings that are not closable, for example in doors, windows, in conjunction with an air supply/ extractor box or through other technical measures. In any case, consult a qualified chimney sweep who can assess the entire ventilation of your house and propose appropriate measures for adequate ventilation.

If the hood is used exclusively in the recirculation mode, unrestricted operation is possible.

WARNING
Fire hazard from flying sparks. Only install equipment on a fi replace for solid fuels (for example, wood or coal), if a closed, non-removable cover is available.

DIMENSIONS

Model No.: LUNA 50 – Product Code: TLN50S, TLN50B
Model No.: SELENA 50 – Product Code: TSL50S, TSL50B

DIMENSIONS

HOLE MEASUREMENTS FOR INSTALLATION

Model No.: AMIRA 50 – Product Code TAM50S, TAM50B

DIMENSIONS

HOLE MEASUREMENTS FOR INSTALLATION

INSTALLATION

Note: When the range hood and appliance supplied with energy other than electricity are simultaneously in operation, the negative pressure in the room must be not exceed 4 Pa (4 x 10-5 Bar).

Required minimum distance hood to
Ceramic-glass rings/hotplates 65 cm
Gas cooker 75 cm
Coal / oil / stove wood firing 85 cm

Installation Steps

Note: Do not connect the power cable until the installation is complete! Get a second person to help you with the installation.

  1. Saw an opening in the wall cabinet under which the hood is to be fitted. Use the following dimensions as a guide:
    Installation Steps

  2. Insert the range hood into the cabinet. Please make sure the elastic pins of the both sides are fixed on the cabinet.
    Installation Steps

  3. Remove the metal grease filter
    Installation Steps

  4. Adjust the screws 1. 2 .3 .4 .until the flanges of the both sides are fixed on the cabinet.as the image 5
    Installation Steps
    Installation Steps

  5. Reinstall the matel grease filter(Image 6),and compelet the installation(Image 7)
    Installation Steps
    Installation Steps

  6. The size of the duct.
    Model No.: LUNA 50 – product Code:TLN50S, TLN50B
    Model No.: SELENA 50 – product Code:TSL50S, TSL50B
    Model No.: AMIRA 50 – product Code TAM50S, TAM50B
    Installation Steps

  7. Installation of check valve (Image8), suction pipe,(Image9) and electrical connection (Image10)
    Model No.: LUNA 50 – product Code:TLN50S, TLN50B
    Model No.: SELENA 50 – product Code:TSL50S, TSL50B
    Model No.: AMIRA 50 – product Code TAM50S, TAM50B
    Installation Steps
    Installation Steps

  8. Installation of the duct adaptor
    Installation Steps

  9. Installation of the carbon filter – CODE: TCF1 (not included)
    Model No.: LUNA 50 – product Code:TLN50S, TLN50B
    Model No.: SELENA 50 – product Code:TSL50S, TSL50B
    Model No.: AMIRA 50 – product Code TAM50S, TAM50B
    Installation Steps

AMIRA 50 – Product Code: TAM50S, TAM50B

Technical data

  Value Unit
Lighting efficiency class A
Maximum air flow – high 614.8 m7/h

Air flow at working point – high

Air flow at working point – low

| 593.9| m7/h
360.8| m7/h
Electric power input| 126.7| W
Nominal power of the lighting system| 3| W
Sound power level – boost

Sound power level – high Sound power level – low

| –| dB
70| dB
61| dB
Energy Efficiency class| B|
Annual Energy Consumption| 53.8| kWh/a
Connection diameter – minimum| 120| mm

AMIRA 50 – FUNCTIONS

When the unit is connected, a short beep sounds and the backlight of the buttons lights up briefly.
The unit enters standby mode.

LED light on / off
With the
button you can switch the illumination of the hood on and off in any mode / operating state.

On / Off
Press the
ibutton in standby mode to turn on the unit.
The backlighting of the buttons will indicate the operating mode and the appliance will start working.
In the operating mode you can interrupt the operation by briefly pressing the key ( ****key remains illuminated) and switch off the appliance by holding it down (all key illuminations off).

Setting the power level
The appliance has three power levels and one high-performance level (booster).
After switching on, operation starts at the first power level.
Now use the
key to increase the power and the ****key to decrease it.

The flashing of the key illumination and displays the status:
Level 1: 2 sec. frequency
Level 2: 1.5 sec. frequency
Level 3: 1 sec. frequency

5minute timer / Automatic switch-off

If the and and keys are pressed simultaneously during operation, the 5min. automatic switch-off is activated.
The illumination of the flashes and the and ****keys light up.

After 5 minutes, a beep sounds and the appliance automatically switches to standby mode.

You can deactivate the 5-minute timer by pressing the and and keys simultaneously again during the countdown.

SELENA 50 – Product Code: TSL50S, TSL50B

Technical data

  Value Unit
Lighting efficiency class A
Maximum air flow – high 614.8 m7/h

Air flow at working point – high

Air flow at working point – low

| 593.9| m7/h
360.8| m7/h
Electric power input| 126.7| W
Nominal power of the lighting system| 3| W
Sound power level – boost

Sound power level – high Sound power level – low

| –| dB
70| dB
61| dB
Energy Efficiency class| B|
Annual Energy Consumption| 53.8| kWh/a
Connection diameter – minimum| 120| mm

SELENA 50 – FUNCTIONS

When the unit is connected, a short beep sounds and the backlight of the buttons lights up briefly.
The unit enters standby mode.

LED light on / off
With the
button you can switch the illumination of the hood on and off in any mode / operating state.

On / Off
Press the
ibutton in standby mode to turn on the unit.
The backlighting of the buttons will indicate the operating mode and the appliance will start working.
In the operating mode you can interrupt the operation by briefly pressing the key ( ****key remains illuminated) and switch off the appliance by holding it down (all key illuminations off).

Setting the power level
The appliance has three power levels and one high-performance level (booster).
After switching on, operation starts at the first power level.
Now use the
key to increase the power and the ****key to decrease it.

The flashing of the key illumination and displays the status:
Level 1: 2 sec. frequency
Level 2: 1.5 sec. frequency
Level 3: 1 sec. frequency

5minute timer / Automatic switch-off

If the and and keys are pressed simultaneously during operation, the 5min. automatic switch-off is activated.
The illumination of the flashes and the and ****keys light up.

After 5 minutes, a beep sounds and the appliance automatically switches to standby mode.

You can deactivate the 5-minute timer by pressing the and and keys simultaneously again during the countdown.

LUNA 50 – Product Code: TLN50S, TLN50B

Technical data

  Value Unit
Lighting efficiency class A
Maximum air flow – high 434.2 m7/h

Air flow at working point – high

Air flow at working point – low

| 400.1| m7/h
310.7| m7/h
Electric power input| 64.8| W
Nominal power of the lighting system| 3| W
Sound power level – boost

Sound power level – high Sound power level – low

| –| dB
59| dB
55| dB
Energy Efficiency class| C|
Annual Energy Consumption| 42.4| kWh/a
Connection diameter – minimum| 120| mm

LUNA 50 – FUNCTIONS

| Depress this button to turn off the motor
---|---
| Low – Depress this button to enter into low speed and again to turn off motor.
| Medium – Depress this button to enter into medium speed and again to turn off motor.
| High – Depress this button to enter into high speed and again to turn off motor.
| Turn on/off LED light.

CLEANING AND CARE

Monthly Cleaning for Grease Filter

Clean the filter every month can prevent any risk of fire. The filter collects grease, smoke and dust, so the filter is directly affecting the efficiency of the cooker hood. If not cleaned, the grease residue (potential flammable) will saturate on the filter. Clean it with household cleaning detergent.

Annual Cleaning for Activated Filter
Apply solely to unit that installed as a recirculation unit (not vented to the outside). This filter traps odours and must be replaced at least once a year depending on how frequent the cooker hood used.

Replacing Bulbs

  1. Switch the unit off and unplug the appliance.
  2. Remove the lamp cover by unscrewing the 2 screws.
  3. Unscrew the incandescent bulb. Replace with the same type and rated bulb.

TROUBLESHOOTING

Fault Cause Solution
Light on, but fan does not work The fan blade is jammed. Switch of the unit

and repair by qualified service personnel only.
The motor is damaged.
Both light and fan do not work| light bulb burn.| Replace the bulb with correct rating.
Power cord looses.| Plug in to the power

supply again.

Serious Vibration of the unit| The fan blade is damaged.| Switch of the unit and repair by qualified service personnel only.
The fan motor is not fixed tightly.
The unit is not hung properly on the bracket.| Take down the unit and check whether the bracket is in proper location.
Suction performance not good| Too long distance between the unit and the cooking plane| Readjust the distance to 65-75cm

HINTS ON DISPOSAL

According to the European waste regulation 2012/19/EU this symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local council or your household waste disposal service.

Manufacturer

Intax Trading SRL
14B Ion Creanga Str., 075100, Otopeni, Ilfov, Romania

2 Years Warranty

This warranty covers defects of construction, manufacturing and material.
Excluded are all wearing parts and improper usage, or consequential damages due to lack of cleaning of the appliance.

turbionaire