turbionaire THEA 50-75 Kitchen Hood Instruction Manual
- June 9, 2024
- turbionaire
Table of Contents
turbionaire THEA 50-75 Kitchen Hood
SAFETY INSTRUCTIONS
- Thank you for purchasing this cooker hood. Please read the instruction manual carefully before you use the cooker hood, and keep it in a safe place.
- The installation work must be carried out by a qualified electrician or competent person. Before you use the cooker hood, make sure that the voltage (V) and the frequency (Hz) indicated on the cooker hood are exactly the same as the voltage (V) and the frequency (Hz) in your home.
- The manufacturer and the agent will not bear any responsibility for the damage caused by inappropriate installation and usage.
- Never let children operate the cooker hood.
- The cooker hood is for home use only. It is not suitable for barbecues, Roast shop and commercial purposes.
- The cooker hood and its filter mesh should be cleaned regularly in order to keep it in good working order.
- Before cleaning, switch the power off at the main supply.
- Clean the cooker hood according to the instruction manual and keep the cooker hood from the danger of burning.
- Prohibit putting the cooker hood by fire.
- If there is any fault with the appliance, please call the service department to request a service engineer.
- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The instructions shall state the substance of the following: there shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
- Do not flambé under the range hood. Accessible parts may become hot when used with cooking appliances.
Important Hints on Installation
- The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
- Regulations concerning the discharge of air have to be fulfilled.
Important notes about the extraction mode
WARNING
Risk of poisoning from exhaust gases sucked back. Never operate the device in
extraction mode simultaneously with an open flue appliance when there is not
adequate airflow guaranteed.
Open flue combustion equipment (for example, gas, oil, wood or coal-fired heaters, tankless water heaters, water heaters) pulls combustion air from the room and runs it through an exhaust pipe or chimney to the outside. In the extraction mode, indoor air is removed from the kitchen and the adjacent rooms – without sufficient air intake this creates a vacuum. Toxic gases from the chimney or extraction fl ue can thereby be sucked back into the living spaces.
- Always ensure that a sufficient supply of fresh air is guaranteed and that the air can circulate.
- An air supply / extractor box alone does not ensure compliance with the limit value.
Safe operation is only possible when the negative pressure in the room where
the appliance is located does not exceed 4 Pa (0.04 mbar). This can be
achieved when the air required for combustion can flow through openings that
are not closable, for example in doors, windows, in conjunction with an air
supply/ extractor box or through other technical measures. In any case,
consult a qualified chimney sweep who can assess the entire ventilation of
your house and propose appropriate measures for adequate ventilation.
If the hood is used exclusively in the recirculation mode, unrestricted
operation is possible.
WARNING
Fire hazard from flying sparks.
Only install equipment on a fire place for solid fuels (for example, wood or
coal), if a closed, non-removable cover is available.
DIMENSIONS
Model No.: THEA – Product Code TH50RCB,TH50RC
DIMENSIONS
THEA 75 – Product Code TH75RCB, TH75RC
INSTALLATION
Note: When the range hood and appliance supplied with energy other than electricity are simultaneously in operation, the negative pressure in the room must be not exceed 4 Pa (4 x 10-5 Bar).
Required minimum distance hood to
- Ceramic-glass rings/hotplates 65 cm
- Gas cooker 75 cm
- Coal / oil / stove wood firing 85 cm
Installation Steps
Note: Do not connect the power cable until the installation is complete! Get a second person to help you with the installation.
- Saw an opening in the wall cabinet under which the hood is to be fitted. Use the following dimensions (mm) as a guide:
- Insert the range hood into the cabinet. Please make sure the elastic pins of the both sides are fixed on the cabinet.
- Remove the metal grease filter
- Adjust the screws 1. 2 .3 .4 . until the flanges of the both sides are fixed on the cabinet as the Image 5
- Reinstall the motel grease filter (Image 6), and complete the installation (Image 7)
- The size (mm) of the duct.
- Installation of check valve (Image 8), suction pipe, (Image 9) and electrical connection (Image 10) Model No.: THEA 50 – Product Code TH50RCB,TH50RC
- Installation of the duct adaptor
- Installation of the carbon filter – CODE: TCF1 (not included)
Model No. : THEA 50/ 50 BLACK – product Code TH50RCB, TH50RC
THEA – Product Code TH50RCB, TH50RC
Technical data
| Value| Unit
---|---|---
Motor airflow| 800| m³/h
Maximum cooker hood airflow – boost| 607.2| m³/h
Cooker hood airflow at working point – high
Cooker hood airflow at working point – low| 542.2| m³/h
344.9| m³/h
Electric power input| 124| W
Nominal power of the lighting system| 4| W
Sound power level – boost Sound power level – high
Sound power level – low| 67| dB
65| dB
55| dB
Energy Efficiency class| A+|
Annual Energy Consumption| 23.4| kWh/a
Connection diameter – Minimum/ Optimum| 120/150| mm
THEA 75 – Product Code TH75RCB, TH75RC
Technical data
| Value| Unit
---|---|---
Motor airflow| 800| m³/h
Maximum air flow – Boost| 691.9| m³/h
Cooker hood airflow at working point – high
Cooker hood airflow at working point – low| 612.8| m³/h
312.6| m³/h
Electric power input| 125| W
Nominal power of the lighting system| 5| W
Sound power level – boost Sound power level – high
Sound power level – low| 66| dB
65| dB
50| dB
Energy Efficiency class| A++|
Annual Energy Consumption| 27.2| kWh/a
Connection diameter – Minimum/ Optimum| 120/150| mm
THEA 50/ 50 BLACK – FUNCTIONS
- ON/ OFF Key – turning ON/ OFF the Fan
- + Speed plus key – For increasing the speed of the fan. Long press this icon for booster setting, will go back to high speed after operating for 5 minutes.
- – Speed decrease key – For decreasing the speed of the fan.
- Light Key – turning ON/ OFF the light
- Digital Display – Fan speed display:
“1” f or Low speed, “2” f or Medium speed, “3” for High speed, “B” for Booster speed, “C” for air cleaning function.
Quick timer: Press & simultaneously for 1 second. The digital display flashes & the countdown starts for 5 minutes. After 5 minutes, the motor & the light will turn off automaticaly & the Buzzer sound will keep buzzing for 5 seconds if there is no other operations, the buzzer sound can be stopped by depressing any button during the buzzing. If need to stop this function during the countdown, press & simultaneously for 1 second again.
Air cleaning function
In standby state, long press the key for 3 seconds to enter the air cleaning
function. This function automatically shuts down after 5 minutes of low speed
operation. After 55 minutes of stop, it automatically runs again for 5 minutes
and then stops again for 55 minutes. “C” is displayed on the display screen
during low speed operation. After this function is started, it can only be
turned off by pressing the on key again for 1 second, without affecting other
normal switch operations (the key blinks when entering the air cleaning
function).
How to match the remote control
In standby state, long press the button for 3 seconds to enter the remote
control matching state, and the indicator light keeps flashing. In the
matching state, press the remote control button and a beep sound will be
heard, the remote is successfully matched. If no operation is performed or the
match fails after 15 seconds, the system returns to the standby state.
How to use the remote control
- ON/ OFF Key – turning ON/ OFF the Fan
- + Speed plus key – For increasing the speed of the fan. Long press this icon for booster setting, will go back to high speed after operating for 5 minutes.
- – Speed decrease key – For decreasing the speed of the fan.
- Light Key – turning ON/ OFF the light
Gesture control
In standby state, gesture from left to right means increase the speed. Gesture
from right to left means decrease the speed.
The 1st gesture from left to right into the low speed, the corresponding
indicator light is on; keep gesturing from left to right, the speed will go
into Medium speed – High speed – Booster speed (automatically jumps back to
third gear after running for 5 minutes).
When the motor is running, the 1st gesture from right to left enters the
function of quick timer (automatically turn off after running for 5 minutes),
the digital blinking on the display. Gesturing one more time from right to
left, the hood will be turned OFF. In standby state, the gesture switch from
right to left does not respond.
STAINLESS STEEL SURFACES CLEANING
To avoid damaging the stainless steel surface of your appliance
Always clean with:
Soft cloths, distilled or filtered water, as well as detergents specially made
for stainless steel.
Do not clean with:
Abrasive materials, cleaning powders, bleach and other chlorine-based
products, ammonia-containing glass cleaners, tap water especially if it tends
to be hard water, oven cleaners.
Damage to stainless steel surfaces due to the use of improper cleaning
substances is not covered by the warranty.
TROUBLESHOOTING
Fault | Cause | Solution |
---|---|---|
Light on, but fan does not work | The fan blade is jammed. | Switch of the unit |
and repair by qualified service personnel only.
The motor is damaged.
Both light and fan do not work| light bulb burn.| Replace the bulb with
correct rating.
Power cord looses.| Plug in to the power supply again.
Serious Vibration of the unit| The fan blade is damaged.| Switch of the unit
and repair by qualified service personnel only.
The fan motor is not fixed tightly.
The unit is not hung pro-perly on the bracket.| Take down the unit and check
whether the bracket is in proper location.
Suction performance not good| Too long distance between the unit and the
cooking plane| Readjust the distance to 65-75cm
HINTS ON DISPOSAL
According to the European waste regulation 2012/19/EU this symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local council or your household waste disposal service.
Manufacturer
Intax Trading SRL
14B Ion Creanga Str., 075100, Otopeni, Ilfov, Romania
office@intaxtrading.com
www.intaxtrading.com
References
- Dehumidifiers, Portable Air Conditioners| Intax Trading
- Dehumidifiers Fans Air Conditioners| Turbionaire
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>