Hunter PGV-ASV 1 Inch Anti Siphon Female NPT Valve Instructions
- June 16, 2024
- Hunter
Table of Contents
Built on Innovation
PGV-ASV
Gain simple and trouble-free operation without the need for a separate
backflow preventer.
PGV-ASV 1 Inch Anti Siphon Female NPT Valve
Size: ¾”, 1″¾”, 1″
Flow: 0.2 to 40 GPM
|
---|---
PGV-075-ASV
Inlet Diameter: ¾”
Height: 5½”
Length: 5¾”
Width: 2 ½”| PGV-101-ASV
Inlet Diameter: 1″
Height: 5½”
Length: 6¼”
Width: 2 ½”
Key Benefits
- External/internal manual bleed allows for quick and easy activation at the valve
- Captive bonnet screws eliminate the possibility of lost parts during disassembly Removable anti-siphon cap for simple servicing
- Flow control maximizes efficiency and prolongs the life of the system
- Double-beaded diaphragm seal design ensures leak-free performance
- Triple-tool bonnet screws are compatible with standard or Phillips screwdrivers as well as a nut driver
- Encapsulated solenoid with captive plunger used on every Hunter valve provides hassle-free service
User-Installed Options
- Accu Sync® pressure regulation at the valve
- DC-latching solenoid for batterypowered controllers (P/N 458200)
Factory-Installed Options
- LS: Valve without solenoid
- DC-latching solenoid for batterypowered controllers (P/N 458200)
Operating Specifications
- Flow: 0.2 to 40 GPM
- Temperature rating: 150°F
- Recommended pressure range: 20 to 150 PSI
- Warranty period: 2 years
¾” PGV-ASV
| ModelModel | Description |
|---|---|
| PGV-075-ASV | ¾” plastic anti-siphon electric valve, with flow control, NPT |
inlets
PGV-075-ASV-S| ¾” plastic anti-siphon electric valve, with flow control, slip
inlets
PGV-075-ASV-LS| ¾” plastic anti-siphon electric valve, with flow control, NPT
inlets, no solenoid
1″ PGV-ASV
| ModelModel | Description |
|---|---|
| PGV-101-ASV | 1″ plastic anti-siphon electric valve, with flow control, NPT |
inlets
PGV-101-ASV-S| 1″ plastic anti-siphon electric valve, with flow control, slip
inlets
PGV-101-ASV-LS| 1″ plastic anti-siphon electric valve, with flow control, NPT
inlets,
no solenoid
Accu-Sync® Pressure Regulation Models:
| ModelModel | Description |
|---|---|
| ACCUSYNC-ADJ | Adjustable 20-100 PSI Pressure Regulator |
| ACCUSYNC-30 | Fixed 30 PSI Pressure Regulator |
| ACCUSYNC-40 | Fixed 40 PSI Pressure Regulator |
PGV-ASV PRESSURE LOSS IN PSI
| Flow | ¾” | 1″ |
|---|---|---|
| GPM | ||
| 1 | 1 | 1 |
| 5 | 2 | 2 |
| 10 | 2 | 2 |
| 15 | 3 | 3 |
| 20 | 6 | 6 |
| 25 | 6 | |
| 30 | 9 | |
| 35 | 16 |
VISIT HUNTERINDUSTRIES.COM
RESIDENTIAL & COMMERCIAL IRRIGATION | Built on Innovation