wiltec CET-26000 SuperECO Pond Pump User Manual

June 5, 2024
wiltec

Operation Manual
SuperECO Pond Pump CET-26000
55550

wiltec CET 26000 SuperECO Pond Pump

Illustrations similar may vary depending on model

Read and follow the operating instructions and safety information before using it for the first time.
Technical changes reserved!
Due to further developments, illustrations, functioning steps, and technical data can differ insignificantly.
Updating the documentation
If you have suggestions for improvement or have found any irregularities, please contact us.

The information contained in this document may alter at any time without previous notice. It is prohibited to copy or spread any parts of this document in any way without prior written allowance. All rights reserved.
The WilTec Wildanger Technik GmbH cannot be held accountable for any possible mistakes in this operating manual, nor in the diagrams and figures shown.
Even though the WilTec Wildanger Technik GmbH has undergone the biggest possible efforts to ensure that the operating manual is complete, faultless, and up to date, mistakes cannot be entirely avoided. If you should find a mistake or wish to make a suggestion for improvement, we look forward to hearing from you.

Send an e-mail to: [email protected] or use our contact form: https://www.wiltec.de/contacts/The most recent version of this manual in various languages can be found in our online shop via: https://www.wiltec.de/docsearch 

Our postal address is:

WilTec Wildanger Technik GmbH
Königsbenden 12
52249 Eschweiler
Germany

Do you wish to pick goods up? Our pick-up address is:

WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
Germany

To shorten the waiting time and allow for a rapid on-site transaction, we ask you to call us previously or place your order via the webshop.

E-mail: [email protected]
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15

To return orders for exchange, repair, or other purposes, please use the following address. Attention!
To allow for smooth execution of your complaint or return, it is important to contact our customer service team before returning the goods.
Returns Department
WilTec Wildanger Technik GmbH
Königsbenden 28
52249 Eschweiler
E-mail: [email protected]
Tel: +49 2403 55592–0
Fax: +49 2403 55592–15

Introduction

Thank you for purchasing this quality product. To minimize the risk of injury we urge that our clients take some basic safety precautions when using this device. Please read the operation instructions carefully and make sure you have understood its content. Keep these operation instructions safe.
Unpacking
Inform your vendor in case any piece should be damaged.

Caution

  • For your own safety, contact an electrical professional in case of questions and problems.
  • Do not connect the device to the power supply before all parts have been installed.
  • Only connect the pump to an (earthed) shockproof socket. This type of socket must comply with the respective national guidelines (VDE, EN, IEC, etc.). Make sure that the neutral conductor (PE conductor; protected earth) leads continuously to the pump.
  • Make sure that the voltage of the pump and that of the power supply match.
  • Electrical installations in garden ponds must comply with national and supranational regulations.
  • Only operate the pump when nobody is in the water.
  • Do not carry or pull the pump by the power cord; the cable should neither overheat nor touch sharp edges.
  • The pump must not be put into operation if the cable or the housing is damaged.
  • Only pump water with this pump.
  • Attention: The pump switches off automatically in the event of overvoltage or dry running without water.
  • The controller is not designed to be waterproof. It must therefore be kept in a dry and ventilated place.

Application

For garden ponds, rockeries, aquariums with fish and other sea animals

Features

  • High flow rate, 10 different setting levels
  • Robust filter housing made of stainless steel
  • Special housing that prevents clogging
  • New energy-efficient frequency conversion technology
  • Suitable for both freshwater and saltwater aquarium
  • Ceramic shaft, for a long service life
  • Automatic dry run detection, with alarm function

Installation

  1. Notify your vendor immediately if there are external damages.

  2. Compare the line voltage (V) and frequency (Hz) of your electrical circuit with the data on the model plate; these data must agree.

  3. When connecting the pipe, drain air in the pipe as far as possible.
    (Caution: There must be no air in the pipes; otherwise, the dry run protection might be activated.)

  4. Attention: The pump must be at a position that is at least 20 cm below the water level; the pump must continuously be surrounded completely by water.

  5. Do not place the pump directly in the pond floor mud, place it on a raised surface.

  6. Connect the pump with the controller of four core wires (Fig. 1, 1), and lock the nut (Fig. 1, 2).wiltec CET 26000 SuperECO Pond Pump - fig1

  7. Connect the power supply of the controller.

Controller operation instructions

  1. On/off
    Plug in the device and touch **** to switch the pump on and off. If the device is not operated for a long time, please unplug it.

  2. Flow rate adjusting
    Press or to adjust the flow rate; the device disposes of 10 levels, and the display screen will show “SP01”–“SP10.” For detailed information please refer
    to the parameter list:

Power supply| Level| Power (W)| Flow rate (L/h)| Flow head (m)
---|---|---|---|---
220-240 V/50 Hz| 1| 8o| 13,000| 3.
2| 100| 14,000| 3.
3| 130| 15,500| 4.0
4| 160| 17,00o| 5.
5| 200| 18,000| 5.
6| 24o| 19,000| 6.
7| 285| 20,500| 7.
8| 335| 22,000| 7.
9| 38o| 23,500| 8.
10| 450| 26,000| 9.
3. Feeding mode
Press for 3 s to enter the time delay start mode, and the screen will show “FD10.” The device will start to work after 10 min. Again press for 3 s to quit the feeding mode.

  1. LOCK function
    Long press to lock the keys, and the screen will show “LOC.” Long press to unlock the keys.

  2. Automatic memory function When the controller powers off accidentally, the device will save the last working condition automatically and will return to these conditions after the device will have been re-powered on. Thus, the settings will be saved when there is a power failure e. g.

  3. Alarm function
    The pump will automatically stop working if running without water for more than 30 s, then re-start after 3 s, repeating that 5 times and then power off permanently, reporting the error “ER03”; when the pump automatically stops working in case it is blocked, the display screen will show “ER02.” The pump will automatically re-start after the error will have been repaired.

  4. Instruction code definition and troubleshooting

Code Definition Status Trouble shooting
P000 Power Normal
SPoi—io Flow rate level Normal

FDi o—oi
LOC| Feeding mode| Normal
Lock| Normal
ERoi
ERo2
ERo3
ERo4| aor
Overvoltage ge undervolt-| Abnormal| Check the input voltage.
Pump lock protection| Abnormal| Check the pump whether it is stuck.
Pump idling protection| Abnormal| 1. Check the pump whether it works without water.
2. Check whether there is air in the pipe.
Overheating| Abnormal| Clean the pump.
ERo5| Short-circuit| Abnormal| Check the controller.

Maintenance and cleaning

Before any maintenance, cut off the power supply. After a certain time, if the pump has operated continuously, there will be much rubbish on the rotor part. If you do not clean regularly, this will not only affect the normal operation but can also damage the pump itself. So, you need to clean the rotor parts regularly. Proceed as follows:
wiltec CET 26000 SuperECO Pond Pump - fig3wiltec
CET 26000 SuperECO Pond Pump - fig4

  1. Use a hexagonal screwdriver to screw off the 4 screws on the filter cover (see Fig. 1 and 2). Screw off the base plate (see Fig. 2) and take down the filter cover and base plate. Fig. 3 shows the pump after this step.
  2. Use a hexagonal screwdriver to screw off the 4 screws on the impeller chamber (see Fig. 4); take off the impeller chamber. Fig. 5 shows the pump after this step.
  3. Take off the rotor, clean or replace it.
  • If the pump is not used for a long time, please take out the pump from the water, let it run in clean water for a moment, and then clean the inner part. Dry all parts before stocking and stock it at a secure place.
  • When the temperature is lower than 0 ℃, please take out the pump from the water immediately to prevent any freezing damage.

Explosion view and part list

wiltec CET 26000 SuperECO Pond Pump - fig5

No Name No Name No Name
1 Screw M6x4o 7 Pump rotor 13 Back cover
2 Filter basket 8 Gasket 14 Screw M6x2o
3 Outlet g Ceramic bearing 15 Base plate
4 0-ring 10 Body 16 Screw M6x4o
5 Impeller chamber 11 Screw M6x35
6 Front impeller chamber 12 0-ring

Disposal regulations

EU guidelines regarding the disposal of scrap electric appliances (WEEE, 2012/19/EU) were implemented in the law related to electrical and electronic equipment and appliances.
All WilTec electric devices that fall under the WEEE regulations are labeled with the crossed-out wheeled waste bin logo. This logo indicates that this electric equipment must not be disposed of with domestic waste. The company WilTec Technik GmbH has been registered in the German registry EAR under the WEEEregistration number DE45283704.

Disposal of used electrical and electronic appliances(intended for use in the countries of the European Union and other European countries with a separate collection system for these appliances). The logo on the article or on its packaging points out that this article must not be treated as normal household waste but must be disposed to a recycling collection point for electronic and electrical waste equipment. By contributing to the correct disposal of this article you protect the environment and the health of your fellowmen. Environment and health are threatened by inappropriate disposal.

wiltec CET 26000 SuperECO Pond Pump - sambol1

Material recycling helps reduce the consumption of raw materials.
Additional information on recycling this article can be provided by your local community, municipal waste disposal facilities, or the store where you purchased the article.

Address:
WilTec Wildanger Technik GmbH
Königsbenden 12 / 28
D-52249 Eschweiler

Important notice:
The reprint or reproduction, even of excerpts, and any commercial use, even in part, of this instruction manual, require the written permission of WilTec Wildanger Technik GmbH.
© by WilTec Wildanger Technik GmbH
http://www.WilTec.de
http://www.aoyue.eu
http://www.teichtip.de
Item 55550

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

wiltec User Manuals

Related Manuals