Oase 3000, 4500 ProMax Garden Classic Commissioning Instruction Manual

June 3, 2024
Oase

Oase 3000, 4500 ProMax Garden Classic Commissioning

Oase-3000-4500-ProMax-Garden-Classic-Commissioning-
product

WARNING

  • Disconnect all electrical devices in the water from the power supply before reaching the water. Otherwise, there is a risk of severe injuries or death by electrocution.
  • This unit can be used by children aged 8 and above and by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they are supervised or have been instructed on how to use the unit in a safe way and they understand the hazards involved. Do not allow children to play with the unit. Only allow children to carry out cleaning and user maintenance under supervision.

Further instructions in a PDF format are available for download online at: www.oase.com/manualOase-3000-4500-ProMax-Garden-Classic-Commissioning-
fig-4 The following additional topics are addressed in the operating manual:

  • Shut-down
  • Cleaning and maintenance, storage/winter-proofing, malfunction repair
  • Technical data
  • Disposal

Safety information

Electrical connection

  • Special regulations apply for electrical installation in outdoor spaces. Only a qualified electrician may perform the electrical installation.
    • The qualified electrician has the necessary professional training, knowledge and experience to perform electrical installation in outdoor spaces. The electrician can detect potential dangers and knows how to adhere to regional and national standards, regulations and directives.
    • For your own safety, please consult a qualified electrician.
  • Only connect the unit if the electrical data of the unit and the power supply match.
  • Only plug the unit into a correctly installed outlet. Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
  • Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash-proof).
  • Protect open plugs and sockets from moisture.

Safe operation

  • Do not expose the pump to rain or use it in a wet or damp environment.
  • Do not use the unit, if electrical lines or the housing are damaged.
  • If a power connection cable is damaged, have it immediately replaced by OASE, an authorised customer service or a qualified electrician to prevent electric shock.
  • Do not carry or pull the unit by its power cable.
  • Route lines in such a way that they are protected from damage and do not present a tripping hazard.
  • Never carry out technical changes to the unit.
  • Only carry out work on the unit that is described in this manual.
  • Only use original spare parts and accessories.

Intended use

Only use the product described in this manual as follows:

  • For transferring water from and draining basins or ponds/pools.
  • For irrigating and watering.
  • For pumping clear water or rain water.
  • Extraction of water from a well.
    • Only for irrigation and watering purposes!
  • For pumping the water out of water butts/rain barrels or cisterns.
    • Size of the particles in the water: max. 2 mm.
  • To boost the pressure of the mains water.
    • Max. permissible internal pressure of the pump on the pressure side: 6 bar
  • While adhering to the technical specifications.

The following restrictions apply to the unit:

  • Do not use for long-term operation (e.g. continuous recirculation of the water in a pond).
  • Not suitable for salt water.
  • Never use for pumping dirty water/waste water.
  • Do not connect to the drinking water supply.
  • Not suitable for drinking water.
  • Do not use for commercial or industrial purposes.
  • Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.

Product Description

Overview

  • The unit contains cast iron, which is subject to a natural corrosion process. This does not impair the function of the unit.

Installation and connection

NOTE
If you are using the pump as a booster pump, ensure that the max. internal pressure of 6 bar on the pressure side is not exceeded.

  • The pump pressure is added to the pre-pressure.
  • Example: Pre-pressure = 1 bar, max. pressure of the pump = 4.5 bar, total pressure = 5.5 bar.
  • To reduce pump noise, connect the pump to the pipework via flexible, pressure-resistant hose lines for fixed installation.
  • Equip the suction line with a pre-filter and a non-return or foot valve. In addition, fasten the suction hose (e.g. tying it to a stake) to take its weight off the pump.

A ****

  • Install the pump in a horizontal and stable position in a dry place.
    • For permanent installation of the pump, ensure that a sufficiently large collecting basin can be positioned underneath the discharge screw for emptying the pump.
  • If possible, install the pump in a higher position than the container/reservoir from which the water is to be pumped. If this is not possible, a pressure-proof valve must be fitted between the pump and the suction hose.
  • Only use vacuum-proof pressure hoses on the pressure and suction side.
  • Screw a suction and pressure hose with 25.0 mm internal diameter (1″) onto the connections.

Operation

CAUTION
Risk of burns due to hot water. Water in the pump may be heated to a high temperature in the event of defective electronics or lack of water supply on the suction side.

  • Disconnect the power plug before carrying out any work on the unit.
  • Allow the water in the pump to cool down.

Starting up the unit
It is necessary to fill the pump and expel the air from the suction line before using. It can take several minutes to expel air from the suction line.

How to proceed:

B

  1. Unscrew the water infill screw.
  2. Pour water into the infill opening until it overflows.
  3. Screw in the water infill screw again.
  4. Open the pressure line if necessary.
  5. Insert the power plug into the socket.
  6. Switch on the pump.
    • The pump starts pumping immediately. The emerging water still contains some air.