CONDTROL 7-2-105 XLiner Pento 360 Cross Line Laser User Manual
- June 4, 2024
- CONDTROL
Table of Contents
XLiner Pento 360 Cross Line Laser
User Manual
Congratulations on your purchase of the laser level XLiner Pento 360 / Quattro 360 G / Pento 360 G CONDTROL. Safety instructions can be found in the end of this user annual and should be carefully read before you use the device for the first time.
SAFETY INSTRUCTIONS
Attention! This user manual is an essential part of this product. The
user manual should be read carefully before you use the product for the first
time. If the product is given to someone for temporary use, be sure to encthe
lose user manual to it.
– Do not misuse the product
– Do not remove warning signs and protect them from abrasion, because they
contain information about the safe operation of the product.
LASER RADIATION!
Do not stareinto beam
Class 2 laser
<1 mW, 635/515 nm
IEC 60825-1: 2007-03
– Do not look into the laser beam or its reflection, with an unprotected eye
or through an optical device. Do not point the laser beam at people or animals
without the need. You can dazzle them.
– To protect your eyes close them or look aside. – Always install the product
in such a way, so that the laser line is below or above eye level.
– Do not let unauthorized people enter the zone of product operation. – Store
the product beyond the reach of children and unauthorized people.
– Do not disassemble or repair the product yourself. Entrust product repair to
qualified personnel and use original spare parts only.
– Do not use the product in an explosive environment, close to flammable
materials.
– Laser-intensive glasses are used for better recognition of the laser beam;
do not use them for other purposes. Laser glasses do not protect from laser
radiation as well as ultraviolet radiation and reduce color perception.
– Avoid heating the battery to avoid the risk of explosion and electrolyte
leakage. In case of liquid contact with skin, wash it immediately with soap
and water. In case of contact with the eyes, flush with clean water for 10
minutes and consult the doctor.
PRODUCT DESCRIPTION
Cross-line lasers XLiner Pento 360 / Quattro 360 G / Pento 360 G CONDTROL are
intended to project vertical and horizontal planes and lines as well as the
laser dot (zenith and nadir). The laser levels are suitable for use at both
indoor and outdoor building areas.
The cross-line laser has 2 operating modes:
– Automatic leveling to compensate for irregularities within the self-leveling
range of ± 3.5°;
– Locked compensator, to project inclined planes and lines.
Pulse mode allows using a laser receiver to increase the working range of the
laser level or to work when the laser is hard to define in bright lighting
conditions.
- Laser exit windows
- Control panel
- Battery cover
- Thread 1/4’’ for mounting on a tripod
- Thread 5/8’’ for mounting on a tripod
- Switch bar
- Hole for mounting on a screw/nail
- Thread 1/4’’ for mounting on a tripod
- Thread 5/8’’ for mounting on a tripod
Control panel
-
Switch on/off:
– the laser level;
– laser planes. -
Switch on/off pulse mode
-
Power indicator
-
Locked mode indicator
-
Pulse mode indicator
DELIVERY PACKAGE
liner Pento 360/Quattro 360 G/Pento 360 G Laser level, battery (7.4V 2600mAh
Li-ion) 2 pcs, charger, user manual, bag.
XLiner Pento 360 Kit/Quattro 360 G Kit/Pento 360 G Kit
Laser level, battery (7.4V 2600mAh Li-ion) 2 pcs, charging cable, magnetic
target, wall mount, clamp, user manual, plastic case.
TECHNICAL SPECIFICATIONS
XLiner | liner | liner |
---|---|---|
Pento 360 | Quattro 360 | Pento 360 G |
Working range/with receiver | 40/100 m | 60/100 m |
--- | --- | --- |
Accuracy | ±0,2 mm/m | |
Self-leveling range | ± 3,5° | |
Continuous operating time | >18 hours | >8 hours |
Operating temperature | -10°C +50°C | |
Storage temperature | -20°C +70°C | |
Relative humidity | 90% | |
Dust and water protection rate | IP54 | |
Thread for mounting on a tripod | 1/4″ and 5/8″ | |
Laser | Class II |
635 nm
< 1 mW| Class II
515 nm
< 1 mW
Power supply| 7.4V 2600 mAh Li-ion
Dimensions| 155x85x132 mm
Weight: without battery with battery| 0,63 kg
0,73 kg
- The operating range may differ from the declared depending on the lighting conditions.
BEFORE START OPERATION
Power supply
The laser level is powered via a 7.4V 2600mAh Li-ion battery included in the
delivery package.
Install/charge the Li-ion battery
Install the battery in the battery compartment, observing the polarity.
Use the battery included in the delivery package only.
If the power indicator on the control panel starts flashing red, the battery
must be charged.
The charging procedure is as follows:
- Remove the battery from the laser level.
- Connect the battery to the power source by a charging cable, included in the delivery package. The power indicator on the control panel will be red while charging.
- The battery charging time is about 3 hours.
- Once the power indicator on the control panel turns green, disconnect the charger and install the battery in the battery compartment.
OPERATION
Place the laser level on a firm and stable surface or a tripod.
Move the switch bar to select the required operating mode:
-
Automatic leveling:
Move the switch bar to position ON.
The laser level will switch on.
Short press to switch on required lines. If the laser level is out of the range of automatic compensation laser lines will flash 1 time per second.
Short press to switch on/off the pulse mode.
To switch off the laser level move the switch bar to position OFF. -
Projection of inclined planes
The switch bar is in position OFF.
Press and hold for 2 seconds to switch on the laser.
Long press for 2 seconds to switch on required laser lines.
Switched-on laser lines will flash every 5 seconds.
After all possible combinations of lines are switched on, the next long
press will switch off the laser level.
Long press for 2 seconds to switch on/off the pulse mode.
Attention! To increase operating time and avoid the risk of unintentional
blindness switch the laser on only when you are ready to work.
If operated near objects or air streams with temperatures different from the
environment the laser line may tremble due to the heterogeneity of the
atmosphere. The longer the distance, the more trembling of the laser line can
be observed.
The width of the laser line increases as soon as the operating distance
increases as well. The layout should be made along the axis of the laser line.
For maximum accuracy, use the middle portion of the laser line.
It should be noted that the shape of the laser line on the object’s surface
(e.g., walls, ceilings, etc.) depends on the curvature and tilt of the surface
relative to the laser line.
Bluetooth
Bluetooth is always on by default. Switch on the laser level. Activate
Bluetooth at your portable device and start the app “XLiner Remote”.
Perform connection via Bluetooth. The app allows switching on and off the
laser lines and dots, receiver mode, as well as adjusting the brightness of
the laser for optimal visibility and energy saving, and controlling the
battery charge level without touching the laser level.
ACCURACY CHECK
Check the horizontal line
Use 2 parallel vertical walls which are located opposite each other at a
distance of 5 m.
- Set the instrument close to wall A (see Fig. A). Switch on the vertical and horizontal laser emitters, and unlock the compensator. Turn the instrument in such a way so that the laser lines intersecting each other are projected near wall A opposite the instrument. Mark the point where laser lines intersect each other as A1.
- Turn the instrument by 180°, marking the point where laser lines intersect each other on the opposite wall as В2. (see Fig. В).
- Move the instrument to the opposite wall B and set it in such a way that the point where laser lines intersect each other would be on the same level as point B2. (see Fig. C).
- Turn the instrument by 180°, and direct the instrument to the wall А in such a way so that the vertical line would coincide with point А1. Mark the point of intersecting laser line on the wall А an s A3. (see. Fig. D).
- Measure distance d between points А1 and А3 (see. Fig. D). If this distance exceeds 2 mm, please contact the service center.
check of the vertical line
Use a plumb bob as a reference for a vertical line. Place the instrument at
a distance of 1,5m from the plumb bob.
- Unlock the compensator, switch on the vertical laser line and align it with the low point of a plumb bob.
- If the deviation between the laser line and the plumb bob line exceeds ±0.2 mm per 1m of the plumb bob length (for a 2.5m plumb bob deviation shouldn’t exceed 0.5 mm) please contact the service center.
- Turn the instrument by 180° and align the vertical laser line with the low point of plumb bob once again.
CARE AND MAINTENANCE
Attention! The laser level is an accurate optical mechanic device and
requires careful handling. Check the accuracy before using. Maintenance of the
following recommendations will extend the life
of the device:
- Keep the laser level, spare parts, and accessories out of the reach of children and unauthorized people.
- Transport the laser level with a locked compensator only.
- Protect the device from shock, falls, and strong vibrations; do not allow moisture, construction dust, and foreign objects to get inside the laser level.
- In case moisture gets inside the laser level, first of all, remove the battery, and then contact the service center.
- Do not store or use the laser level for a long time in high humidity conditions.
- Arrange the accuracy check of the laser level occasionally (see the paragraph «Accuracy check»).
- Clean the laser level with a soft damp cloth. Do not use harsh chemicals, cleaning solvents or detergents.
- Wipe the laser aperture with a soft, lint-free cloth with isopropyl alcohol.
Failure to comply with the following rules may result in leakage of the electrolyte from the batteries and damage the laser level:
- Remove the battery from the laser level if it is not used for a long time.
- Do not leave discharged battery in the device.
- Do not heat the battery.
UTILIZATION
Expired tools, accessories, and packages should be passed for waste recycling.
Please send the product to the following address for proper recycling:
CONDTROL GmbH
Wasserburger Strasse 9
84427 Sankt Wolfgang
Germany
Do not throw the product in municipal waste!
According to European Directive, 2002/96/ЕC expired measuring tools and their
components must be collected separately and submitted to environmentally
friendly recycling of wastes.
WARRANTY
All CONDTROL GmbH products go through post-production control and are governed by the following warranty terms. The buyer’s right to claim about defects and general provisions of the current legislation does not expire.
- CONDTROL GmbH agrees to eliminate all defects in the product, discovered while the warranty period, that represents the defect in material or workmanship in full volume and at its own expense.
- The warranty period is 24 months and starts from the date of purchase by the end consumer (see the original supporting document).
- The Warranty doesn’t cover defects resulting from wear and tear or improper use, malfunction of the product caused by failure to observe the instructions of this user manual, untimely maintenance and service and insufficient care, and the use of non-original accessories and spare parts. Modifications in the design of the product relieve the seller from responsibility for warranty works. The warranty does not cover cosmetic damage, that doesn’t hinder the normal operation of the product.
- CONDTROL GmbH reserves the right to decide on the replacement or repair of the device.
- Other claims not mentioned above, are not covered by the warranty.
- After holding warranty works by CONDTROL GmbH warranty period is not renewed or extended.
- CONDTROL GmbH is not liable for loss of profit or inconvenience associated with a defect of the device, or the rental cost of alternative equipment for the period of repair.
This warranty applies to German law except for the provision of the United Nations Convention on contracts for the international sale of goods (CISG).
In the warranty case please return the product to the retail seller or send it with a description of the defect to the following address:
CONDTROL GmbH
Wasserburger Strasse 9
84427 Sankt Wolfgang
Germany
www.condtrot.com
CONTROL
LASER DISTANCE METERS
LASER LEVELS
Documents / Resources
|
CONDTROL 7-2-105 XLiner Pento 360 Cross Line
Laser
[pdf] User Manual
7-2-105, XLiner Pento 360, Cross Line Laser, XLiner Pento 360 Cross Line
Laser, 7-2-105 XLiner Pento 360 Cross Line Laser
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>