Schumacher ‎SC1280 Automatic Battery Charger OWNERS MANUAL

June 4, 2024
Schumacher

Schumacher ‎SC1280 Automatic Battery Charger

Schumacher -SC1280-Automatic-Battery-Charger-PRODUCT

  • PLEASE SAVE THIS OWNERS MANUAL AND READ BEFORE EACH USE.
  • This manual will explain how to use the battery charger safely and effectively.
  • Please read and follow these instructions and precautions carefully.

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS.

  1. SAVE THESE INSTRUCTIONS – This manual contains important safety and operating instructions.

  2. This charger is not intended for use by children.

  3. Do not expose the charger to rain or snow.

  4. Use of an attachment not recommended or sold by the battery charger manufacturer may result in a risk of fire, electric shock or injury to persons.

  5. To reduce the risk of damage to electric plug and cord, pull by the plug rather than the cord when disconnecting charger.

  6. An extension cord should not be used unless absolutely necessary. Use of improper extension cord could result in a risk of fire and electric shock. If an extension cord must be used, make sure:

    • That the pins on plug of extension cord are the same number, size and shape as those of plug on charger.
    • That extension cord is properly wired and in good electrical condition
    • That wire size is large enough for AC ampere rating of charger as specified in section 8.
  7. Do not operate charger with damaged cord or plug – replace the cord or plug immediately.

  8. Do not operate charger if it has received a sharp blow, been dropped, or otherwise damaged in any way; take it to a qualified serviceman.

  9. Do not disassemble charger; take it to a qualified serviceman when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire.

  10. To reduce risk of electric shock, unplug charger from outlet before attempting any maintenance or cleaning. Turning off controls will not reduce this risk.

  11. WARNING:
    RISK OF EXPLOSIVE GASES.

    • WORKING IN VICINITY OF A LEADACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE HAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER.
    • To reduce risk of battery explosion, follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery. Review cautionary markings on these products and on engine.

PERSONAL SAFETY PRECAUTIONS

  1. Consider having someone close enough by to come to your aid when you work near a lead-acid battery.
  2. Have plenty of fresh water and soap nearby in case battery acid contacts skin,clothing, or eyes.
  3. Wear complete eye protection and clothing protection. Avoid touching eyes while working near battery.
  4. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, immediately flood eye with running cold water for at least 10 minutes and get medical attention immediately.
  5. NEVER smoke or allow a spark or flame in vicinity of battery or engine.
  6. Be extra cautious to reduce risk of dropping a metal tool onto battery. It might spark or short-circuit battery or other electrical part that may cause explosion.
  7. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead-acid battery. A lead-acid battery can produce a shortcircuit current high enough to weld a ring or the like to metal, causing a severe burn.
  8. Use the charger for charging only LEADACID (STD, AGM, Gel or deep-cycle) rechargeable batteries with recommended rated capacities of24 Ah (6V) and 44- 75Ah (12V). It is not intended to supply power to a low voltage electrical system other than in a starter-motor application. Do not use battery charger for charging dry-cell batteries that are commonly used with home appliances. These batteries may burst and cause injury to persons and damage to property.
  9. NEVER charge a frozen battery.
  10. WARNING: This product contains one or more chemicals known to the State of California to cause cancer and birth defects or other reproductive harm.

PREPARING TO CHARGE

  1. If necessary to remove battery from vehicle to charge, always remove grounded terminal from battery first. Make sure all accessories in the vehicle are off, so as not to cause an arc.
  2. Be sure area around battery is well ventilated while battery is being charged.
  3. Clean battery terminals. Be careful to keep corrosion from coming in contact with eyes.
  4. Add distilled water in each cell until battery acid reaches level specified by battery manufacturer. Do not overfill. For a battery without removable cell caps, such as valve regulated lead acid batteries, carefully follow manufacturer’s recharging instructions.
  5. Study all battery manufacturer’s specific precautions while charging and recommended rates of charge.
  6. determine voltage of battery by referring to car owner’s manual and make sure that output voltage selector switch is set at correct voltage. If charger has adjustable charge rate, charge battery initially at lowest rate.

CHARGER LOCATION

  1. Locate charger as far away from battery as DC cables permit.
  2. Never place charger directly above battery being charged; gases from battery will corrode and damage charger.
  3. Never allow battery acid to drip on charger when reading electrolyte specific gravity or filling battery.
  4. Do not operate charger in a closed-in area or restrict ventilation in any way.
  5. Do not set a battery on top of charger.

DC CONNECTION PRECAUTIONS

  1. Connect and disconnect DC output clips only after setting any charger switches to “off” position and removing AC cord from electric outlet. Never allow clips to touch each other.
  2. Attach clips to battery and chassis, as indicated in sections 6 and 7.

FOLLOW THESE STEPS WHEN BATTERY IS INSTALLED IN THE VEHICLE

WARNING: A SPARK NEAR THE BATTERY MAY CAUSE A BATTERY  EXPLOSION. TO REDUCE THE RISK OF A SPARK NEAR THE BATTERY:

  1. Position AC and DC cords to reduce risk of damage by hood, door, or moving engine part.
  2. Stay clear of fan blades, belts, pulleys, and other parts that can cause injury to persons.
  3. Check the polarity of battery posts. POSITIVE (POS, P, +) battery post usually has larger diameter than NEGATIVE (NEG, N,–) post.
  4. Determine which post of battery is grounded (connected) to the chassis. If negative post is grounded to chassis (as in most vehicles), see (6.5). If positive post is grounded to the chassis, see (6.6).
  5. For negative-grounded vehicle, connect POSITIVE (RED) clip from battery charger to POSITIVE (POS, P, +) ungrounded post of battery. Connect NEGATIVE (BLACK) clip to vehicle chassis or engine block away from battery. Do not connect clip to carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy gauge metal part of the frame or engine block.
  6. For positive-grounded vehicle, connect the NEGATIVE (BLACK) clip from battery charger to NEGATIVE (NEG, N, –) ungrounded post of battery. Connect POSITIVE (RED) clip to vehicle chassis or engine block away from battery. Do not connect clip to carburetor, fuel lines, or sheet-metal body parts. Connect to a heavy gauge metal part of the frame or engine block.
  7. When disconnecting charger, turn switches to off, disconnect AC cord, remove clip from vehicle chassis, and then remove clip from battery terminal.See Operating Instructions for length of charge information.

FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE

WARNING: A SPARK NEAR THE BATTERY MAY CAUSE A BATTERY EXPLOSION. TO REDUCE THE RISK OF A SPARK NEAR THE BATTERY:

  1. Check the polarity of battery posts. POSITIVE (POS, P, +) battery post usually has a larger diameter than NEGATIVE (NEG, N, –) post.
  2. Attach at least a 24-inch-long 6-gauge (AWG) insulated battery cable to the NEGATIVE (NEG, N, –) battery post.
  3. Connect POSITIVE (RED) charger clip to POSITIVE (POS, P, +) post of the battery.
  4. Position yourself and free end of cable as far away from the battery as possible – then connect NEGATIVE (BLACK) charger clip to free end of cable.
  5. Do not face the battery when making final connection.
  6. When disconnecting the charger, always do so in reverse sequence of connecting procedure and break first connection while as far away from battery as practical.
  7. A marine (boat) battery must be removed and charged on shore. To charge it on board requires equipment specially designed for marine use.

GROUNDING AND AC POWER CORD CONNECTIONS

  • This battery charger is for use on a nominal 120 volt circuit. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. The plug pins must fit the receptacle (outlet). Do not use with an ungrounded system.

  • DANGER: Never alter the AC cord or plug provided – if it does not fit the outlet, have a proper grounded outlet installed by a qualified electrician. An improper connection can result in a risk of an electric shock or electrocution.
    NOTE: Pursuant to Canadian Regulations, use of an adapter plug is not allowed in Canada. Use of an adapter plug in the United States is not recommended and should not be used.

  • USING AN EXTENSION CORD
    The use of an extension cord is not recommended. If you must use an extension cord, follow these guidelines:

    • Pins on plug of extension cord must be the same number, size, and shape as those of plug on charger.
    • Ensure that the extension cord is properly wired and in good electrical condition.
    • Wire size must be large enough for the AC ampere rating of charger, as specified:
      Length of cord (feet)| 25| 50| 100| 150
      ---|---|---|---|---
      AWG* size of cord| 18| 18| 16| 14

AWG-American Wire Gauge

ASSEMBLY INSTRUCTIONS

  1. Remove all cord wraps and uncoil the cables before using the battery charger.

CONTROL PANEL

START/STOP BUTTON
Press to immediately begin charging your properly connected battery. If the button is not pressed, charging should begin in ten minutes.

CHARGING STATUS-LED INDICATORS

  1. CHARGING (yellow/orange) LED lit: The charger is charging the battery.
  2. CHARGED (green) LED lit: The battery is fully charged and the charger is in maintenance mode.
  3. CLAMPS REVERSED (red) LED flashing: The connections are reversed.
  4. BAD BATTERY (red) LED lit: The charger has detected a problem with the battery. See Troubleshooting for more information.
    NOTE: See Operating Instructions for a complete description of the charger modes.

DIGITAL DISPLAY
The display will show the battery VOLTAGE when the charger is not charging a battery. When it goes into charging mode, the display will automatically change to ON (to show charging has started) and then show the percent-of- charge of the battery being charged and either 6 or 12 (the voltage of the battery, determined by the charger). If you manually stop the charging process (by pressing the START/STOP button) before the battery is fully charged, the display will show OFF.
NOTE: During charging, the display will go into sleep mode and will not show the percentage of charge or voltage of the battery. To turn the display back on, press any button.

  1. Voltage – The Digital Display shows the voltage at the charger battery clamps in DC volts, or the voltage of the battery, depending on what mode the charger is in.
  2. % – The Digital Display shows an estimated charge percent of the battery connected to the charger battery clamps.

CHARGE RATE
The charger will automatically adjust the charging current, based on battery size, in order to charge the battery completely, efficiently and safely.

RATE SELECTION BUTTON
Use this button to set the maximum charge rate. Press the button until the desired charge rate is selected.

  1. 3A – For charging small batteries, such as those commonly used in garden tractors, snowmobiles and motorcycles. Also used to maintain fully charged large batteries.
  2. 15A – For charging automotive, marine and light truck batteries. Not intended for industrial applications.

BATTERY TYPE BUTTON
Use this button to select the battery type.

  1. Standard – Used in cars, trucks and motorcycles, these batteries have vent caps and are often marked “low maintenance” or “maintenance-free”. This type of battery is designed to deliver quick bursts of energy (such as starting engines) and has a greater plate count. The plates are thinner and have somewhat different material composition. Standard batteries should not be used for deep-cycle applications.
  2. AGM – The Absorbed Glass Mat construction allows the electrolyte to be suspended in close proximity with the plate’s active material. In theory, this enhances both the discharge and recharge efficiency. The AGM batteries are a variant of Sealed VRLA (valve regulated lead-acid) batteries. Popular uses include high-performance engine starting, power sports, deep-cycle, solar and storage batteries.
  3. GEL – The electrolyte in a GEL cell has a silica additive that causes it to set up or stiffen. The recharge voltages on this type of cell are lower than those for other styles of lead-acid battery. This is probably the most sensitive cell in terms of adverse  reactions to overvoltage charging. Gel batteries are best used in VERY DEEP cycle application and may last a bit longer in hot weather applications. If the wrong battery charger is used on a gel cell battery, poor performance and premature failure will result.

OPERATING INSTRUCTIONS

WARNING: A spark near the battery may cause an explosion.
IMPORTANT: Do not start the vehicle with the charger connected to the AC outlet, or it could result in damage to the charger
NOTE: This charger is equipped with an auto-start feature. Current will not be supplied to the battery clamps until a battery is properly connected. The clamps will not spark if touched together.

CHARGING A BATTERY IN THE VEHICLE

  1. Turn off all the vehicle’s accessories.
  2. Keep the hood open.
  3. Clean the battery terminals.
  4. Place the charger on a dry, nonflammable surface.
  5. Lay the AC/DC cables away from any fan blades, belts, pulleys and other moving parts.
  6. Connect the battery, following the precautions listed in sections 6 and 7.
  7. Connect the charger to a live grounded AC outlet.
  8. Select the battery type and charge rate.
  9. Charging will begin within ten minutes and finish automatically. (Press the START/STOP button to begin charging immediately.)
  10. When charging is complete, disconnect the charger from the AC power, remove the clamps from the vehicle’s chassis, and then remove the clamp from the battery terminal.

CHARGING A BATTERY OUTSIDE OF THE VEHICLE

  1. Place battery in a well-ventilated area.
  2. Clean the battery terminals.
  3. Connect the battery, following the precautions listed in sections 6 and 7.
  4. Connect the charger to a live grounded AC outlet.
  5. Select the battery type and charge rate.
  6. Charging will begin within ten minutes and finish automatically. (Press the START/STOP button to begin charging immediately.)
  7. When charging is complete, disconnect the charger from the AC power, disconnect the negative clamp, and finally the positive clamp.
  8. A marine (boat) battery must be removed and charged on shore.

AUTOMATIC CHARGING MODE
When an Automatic Charge is performed, the charger switches to the maintain mode automatically after the battery is charged.

BATTERY CHARGING TIMES

Schumacher -SC1280-Automatic-Battery-Charger-FIG.1

Times are based on a 50% discharged battery and may change, depending on age and condition of battery.

  • ABORTED CHARGE
    If charging cannot be completed normally, charging will abort. When charging aborts, the charger’s output is shut off and the BAD BATTERY (red) LED will light. The digital display will show an error code (see the Troubleshooting section for a description of the error codes). Do not continue attempting to charge this battery. Check the battery and replace, if necessary.

  • DESULFATION MODE
    Desulfation could take 8 to 10 hours. If desulfation fails, charging will abort and the BAD BATTERY (red) LED wil light.

  • COMPLETION OF CHARGE
    Charge completion is indicated by the CHARGED (green) LED. When lit, the charger has switched to the maintain mode of operation.

  • MAINTAIN MODE (FLOAT-MODE MONITORING)
    When the CHARGED (green) LED is lit, the charger has started maintain mode. In this mode, the charger keeps the battery fully charged by delivering a small current when necessary. If the charger has to provide its maximum maintain current for a continuous 12 hour period, it will go into abort mode (see Aborted Charge section). This is usually caused by a drain on the battery or the battery could be bad. Make sure there are no loads on the battery. If there are, remove them. If there are none, have the battery checked or replaced.

  • MAINTAINING A BATTERY
    The SC1280 charges and maintains 6-volt and 12-volt batteries.
    NOTE: The maintain mode technology allows you to safely charge and maintain a healthy battery for extended periods of time. However, problems with the battery, electrical problems in the vehicle, improper connections or other unanticipated conditions could cause excessive current draws. As such, occasionally monitoring your battery and the charging process is required.

USING THE BATTERY VOLTAGE TESTER

  1. With the charger unplugged from the AC outlet, connect the charger to the battery following the instructions given in previous sections.
  2. Plug the charger AC power cord into the AC outlet.
  3. If necessary, press the BATTERY TYPE button until the correct type is indicated.
  4. Read the voltage on the digital display. Keep in mind that this reading is only a battery voltage reading; a false surface charge may mislead you. Compare the reading to the chart below.
    6 V Battery Voltage Reading| 12 V Battery Voltage Reading| Battery Condition
    ---|---|---
    6.4 or More| 12.8 or More| Charged
    6.1 to 6.3| 12.2 to 12.7| Needs Charging
    Less than 6.1| Less than 12.2| Discharged

POWER-UP IDLE TIME LIMIT
If no button is pressed within 10 minutes after the battery charger is first powered up, the charger will automatically switch from tester to charger if a battery is connected. In that case, the charger will be set to charge at the 3A rate and gel cell battery type.

MAINTENANCE AND CARE

A minimal amount of care can keep your battery charger working properly for years.

  • Clean the clamps each time you are finished charging. Wipe off any battery fluid that may have come in contact with the clamps to prevent corrosion.
  • Occasionally cleaning the case of the charger with a soft cloth will keep the finish shiny and help prevent corrosion.
  • Coil the input and output cords neatly when storing the charger. This will help prevent accidental damage to the cords and charger.
  • Store the charger unplugged from the AC power outlet in an upright position.
  • Store inside, in a cool, dry place. Do not store the clamps clipped together, on or around metal, or clipped to the cables.

TROUBLESHOOTING/ERROR CODES

Error Codes

ERROR CODE DESCRIPTION REASON/SOLUTION

F01

| The battery voltage is still under 10V (for a 12V battery) or 5V (for a 6V battery) after 2 hours of charging.| ****

The battery could be bad. Have it checked or replaced.

F02| The charger cannot desulfate the battery.| The battery could not be desulfated; have it checked or replaced.


F03

| ****

The battery was unable to reach the “full charge” voltage.

| May be caused by trying to charge a large battery or bank of batteries on too low of a current setting. Try again with a higher current setting or have the battery checked or replaced.
F04| The connections to the battery are reversed.| The battery is connected backwards. Unplug the charger and reverse the connections to the battery.


F05

| ****

The charger was unable to keep the battery fully charged in maintain mode.

| The battery won’t hold a charge. May be caused by a drain on the battery or the battery could be bad. Make sure there are no loads on the battery. If there are remove them. If there are none, have the battery checked or replaced.
F06| The charger detected that the battery may be getting too hot (thermal runaway).| The charger automatically shuts the current off if it detects the battery may be getting too hot. Have the battery checked or replaced.

If you get an error code, check the connections and settings and/or replace the battery.

Troubleshooting

PROBLEM POSSIBLE CAUSE SOLUTION
Battery clamps do not spark when touched together. The charger is equipped

with an auto-start feature. It will not supply current to the battery clamps until a

battery is properly connected. The clamps will not spark if touched together.

| No problem; this is a normal condition.
The charger will not turn on when properly connected.| AC outlet is dead.

Poor electrical connection. Battery is defective.

| Check for open fuse or circuit breaker supplying AC outlet.


Check power cord and extension cord for loose fitting plug.


Have battery checked.

I cannot select a 6V or 12V setting.| The charger is equipped with Auto Voltage Detection, which automatically detects the voltage and charges the battery.| No problem; this is normal.
The battery is correctly connected, but the CHARGING LED did not light immediately.| If the START/STOP button is not pressed, charging should begin in ten minutes.| No problem; this is normal.
The battery is properly connected, but the CHARGING LED never lit.| The battery voltage is low.| Press the START/STOP button to start charging.
PROBLEM| POSSIBLE CAUSE| SOLUTION
---|---|---
The BAD BATTERY LED

is lit.

| The battery voltage is still below 10V (for a 12V battery) or 5V (for a 6V battery) after 2 hours of charging.

(or)

In maintain mode, the output current is more than 1.5A for 12 hours.


Desulfation was unsuccessful.



Lack of progress is detected and battery voltage is below 14.2V (for a 12V battery) or 7.1V (for a 6V battery).



The battery’s initial voltage is below 12.2V (for a 12V battery) or 6.1V (for a 6V battery) and the total input is less than 1.5 Ah.


The battery voltage drops to below 12.2V (for a 12V battery) or 6.1V (for a 6V battery) in Maintain Mode.

| The battery may be defective. Make sure there are no loads on the battery. If there are, remove them. If there are none, have the battery checked or replaced.



The battery may be defective. Have battery checked or replaced.


The battery may be overheated. If so, allow the battery to cool.

The battery may be too large or have a short circuit. Have battery checked or replaced.


The battery capacity is too low, or the battery is too old. Have it checked or replaced.



The battery won’t hold a charge. May be caused by a drain on the battery or the battery could be bad. Make sure there are no loads on the battery. If there are remove them. If there are none, have the battery checked or replaced.

BEFORE RETURNING FOR REPAIRS

If these solutions do not eliminate the problem, or for more information about troubleshooting, contact customer service for assistance: services@schumacherelectric.com / www.batterychargers.com or call 1-800-621-5485, Monday-Friday 7:00 am to 5:00 pm CST
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT SHIP UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA) number from Customer Service at Schumacher Electric Corporation.

SPECIFICATIONS

  • Input Voltage……………………………………………………………………….120V AC @ 60Hz, 3.6A
  • Output Voltage ………………………………………………..6V or 12V, with auto voltage detection
  • Output Current Rating……………………………………….2A DC @ 6V DC; 15A DC @ 12V DC

LIMITED WARRANTY

SCHUMACHER ELECTRIC CORPORATION, 801 E. BUSINESS CENTER DRIVE, MOUNT PROSPECT, IL 60056-2179, MAKES THIS LIMITED WARRANTY TO THE ORIGINAL RETAIL PURCHASER OF THIS PRODUCT. THIS LIMITED WARRANTY IS NOT TRANSFERABLE OR ASSIGNABLE. Schumacher Electric Corporation (the “Manufacturer”) warrants this charger for one (1) year from the date of purchase at retail against defective material or workmanship that may occur under normal use and care. If your unit is not free from defective material or workmanship, the Manufacturer’s obligation under this warranty is solely to repair or replace your product with a new or reconditioned unit at the option of the Manufacturer. The purchaser must forward the unit, along with proof of purchase and mailing charges prepaid to the Manufacturer or its authorized representatives in order for repair or replacement to occur.
The manufacturer does not provide any warranty for any accessories used with this product that are not manufactured by Schumacher Electric Corporation and approved for use with this product. This Limited Warranty is void if the product is misused, subjected to careless handling, repaired, or modified by anyone other than the Manufacturer or if this unit is resold through an unauthorized retailer. Manufacturer may void this Limited Warranty if a “warranty void if removed” label is removed from the product.

Manufacturer makes no other warranties, including, but not limited to, express, implied or statutory warranties, including without limitation, any implied warranty of merchantability or implied warranty of fitness for a particular purpose. Further, the Manufacturer shall not be liable for any incidental, special or consequential damage claims incurred by purchasers, users or others associated with this product, including, but not limited to, lost profits, revenues, anticipated sales, business opportunities, goodwill, business interruption and any other injury or damage. Any such warranties, other than the limited warranty included herein, are hereby expressly disclaimed and excluded. Some states do not allow the exclusion or limitation of incidental or consequential damages or length of implied warranty, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and it is possible you may have other rights which vary from this warranty.
THIS LIMITED WARRANTY IS THE ONLY EXPRESS LIMITED WARRANTY AND THE MANUFACTURER NEITHER ASSUMES OR AUTHORIZES ANYONE TO ASSUME OR MAKE ANY OTHER OBLIGATION TOWARDS THE PRODUCT OTHER THAN THIS WARRANTY.
Schumacher® and the Schumacher logo are registered trademarks of Schumacher Electric Corporation.

WARRANTY CARD

SAVE ON POSTAGE! ACTIVATE YOUR WARRANTY ONLINE – THE QUICK AND EASY WAY! Go to www.batterychargers.com to register your product online. (No internet access? Send in the completed warranty card.)

1 YEAR LIMITED WARRANTY PROGRAM REGISTRATION

  • MODEL:  _____
  • DESCRIPTION:  ____

This is the only express limited warranty, and the manufacturer neither assumes nor authorizes anyone to assume or make any other obligation. There is no other warranty, other than what is described in the product owner’s manual. The warranty card should be submitted within 30 days of purchase. The customer must keep the ORIGINAL receipt because it will be required for any warranty claims. This warranty is not transferable. Send warranty card only. DO NOT SEND THE UNIT TO THIS ADDRESS FOR REPAIR.

Mail this card to:  Schumacher Electric Corporation 801 Business Center Drive Mount Prospect, IL 60056-2179

  • Name __
  • Street Address___
  • City ____
  • State _____
  • Zip Code _____
  • Phone _____
  • Email ___
  • Store Name Where Purchased ___
  • Date of Purchase _____
  • Store Location ____
  • UPC Number ____
  • Serial Number __  (SEE PRODUCT)
    For faster warranty activation, go to www.batterychargers.com to register your product online

FAQs

What type of batteries can the Schumacher SC1280 charge?

The Schumacher SC1280 can charge standard, AGM, gel, and deep-cycle batteries.

How do you know when the battery is fully charged with the Schumacher SC1280?

What is the maintain mode on the Schumacher SC1280?

The maintain mode on the Schumacher SC1280 keeps the battery fully charged by delivering a small current when necessary.

How long should you use the engine start feature on the Schumacher SC1280?

The Schumacher SC1280 recommends using the engine start feature for 3 to 5 seconds on and 5 minutes off. Charge the battery for 15 minutes before using engine start.

How much voltage does the battery need to start charging with the Schumacher SC1280?

The Schumacher SC1280 requires 0.5 volts of output from the battery in order to start charging.

How does the Schumacher ‎SC1280 charger prevent overcharging of batteries?

The Schumacher ‎SC1280 charger incorporates features like float mode monitoring to prevent overcharging, safeguarding the battery from damage.

What is the advantage of the multi-stage charging capability in the Schumacher ‎SC1280?

The multi-stage charging capability of the Schumacher ‎SC1280 ensures efficient and thorough charging, enhancing battery performance and longevity.

What type of vehicles or equipment can benefit from using the Schumacher ‎SC1280 Automatic Battery Charger?

The Schumacher ‎SC1280 charger is ideal for a wide range of vehicles and equipment, including cars, trucks, motorcycles, lawn tractors, and marine vehicles.

How does the microprocessor-controlled system benefit the charging process in the Schumacher ‎SC1280?

The microprocessor-controlled system in the Schumacher ‎SC1280 ensures precise charging, optimizing battery performance and prolonging battery life.

how does the Schumacher ‎SC1280 Automatic Battery Charger ensure safety during charging?

The Schumacher ‎SC1280 employs safety features like reverse hook-up protection and float mode monitoring, ensuring safe and worry-free charging.

Video-Schumacher ‎SC1280 Automatic Battery Charger

Download this Manual:Schumacher ‎SC1280 Automatic Battery Charger OWNERS MANUAL

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Schumacher User Manuals

Related Manuals