GEBERIT 967.180.00.0 Aqua Clean Shower Toilet User Manual
- June 4, 2024
- GEBERIT
Table of Contents
- GEBERIT 967.180.00.0 Aqua Clean Shower Toilet
- Specifications
- Functional Overview
- How to Use the Device
- Intended use
- Getting to know your device
- How to use the device
- Using the anal shower
- Troubleshooting
- How to clean the device
- Disposal
- Technical data and conformity
- Frequently Asked Questions (FAQ)
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GEBERIT 967.180.00.0 Aqua Clean Shower Toilet
Specifications
- Model: 967.180.00.0(01)
- Intended Use: The shower toilet assigned to the wall-mounted control panel
- Operating Distance: Approximately 5 cm in front of the sensor
- Manufacturer: Geberit
Functional Overview
- Wall-mounted control panel, removable
- LED display
- Mounting plate for wall mounting
- Release opening
The Sensor
The function stored in the basic settings is actuated with a hand motion around 5 cm in front of the wall-mounted control panel.
How to Use the Device
Assigning to the Wall-mounted Control Panel
Prerequisite
- Assign the Geberit AquaClean Mera to the wall-mounted control panel by pressing the button on the side control panel of the shower toilet and the wall-mounted control panel simultaneously for 10 seconds.
- Assign the Geberit AquaClean Sela to the wall-mounted control panel by switching on the shower toilet and pressing the on the wall-mounted control panel for 10 seconds.
- Assign the Geberit AquaClean Tuma to the wall-mounted control panel by pressing the button on the side control panel of the shower toilet and the wall-mounted control panel simultaneously for 10 seconds.
Prerequisite
Hold your hand around 5 cm in front of the sensor.
Result
The LED display lights up for…
For your safety
Intended use
The shower toilet assigned to the wall-mounted control panel can be operated using hand motions approximately 5 cm in front of the sensor. Use for any other purpose is deemed improper.
Misuse
Geberit accepts no liability for the consequences arising from misuse.
Explanation of essential information
The following signal word is used to refer to essential information.
Getting to know your device
Functional Overview
Functions:
- touchless activation of shower toilet functions via sensor
- automatic execution of basic settings programmed on the shower toilet
- LED display during each use
The wall-mounted control panel at a glance
- Wall-mounted control panel, removable
- LED display
- Mounting plate for wall mounting
- Release opening
The sensor at a glance
The function stored in the basic settings is actuated with a hand motion
around 5 cm in front of the wall-mounted control panel.
-
sensor
How to use the device
Assigning to the wall-mounted control panel
Prerequisite
- The basic settings for the shower toilet can be adapted to suit your requirements via remote control.
See the shower toilet user manual.
- Assign the shower toilet using the information for the wall-mounted control panel.
Assign the Geberit AquaClean Mera to the wall-mounted control panel by
pressing the
Assign the Geberit AquaClean Sela to the wall-mounted control panel by
switching on the shower toilet and pressing the
Assign the Geberit AquaClean Tuma to the wall-mounted control panel by pressing the <+> button on the side control panel of the shower toilet and the <Geberit logo> on the wall-mounted control panel simultaneously for 10 seconds.
Result
- The LED display lights up for 4 seconds.
- The shower toilet can be operated using the wall-mounted control panel.
Using the anal shower
Prerequisite
- You are sitting down on the WC seat ring.
- Hold your hand around 5 cm in front of the
sensor.
Result
- The shower procedure starts and runs for a few seconds. It can be stopped at any time by making another hand motion around 5 cm in front of the
sensor.
Troubleshooting
Replacing the batteries
- Unlock the interlock by using the screwdriver on the release opening.
- Pull the bottom of the wall-mounted control panel forward and remove it from the mounting plate.
- Extract the used batteries. Dispose of the used batteries appropriately.
- Insert the new CR2032 batteries.
- Attach the top of the wall-mounted control panel and secure it to the mounting plate.
The wall-mounted control panel is without function
The following table will help you with troubleshooting if:
- the wall-mounted control panel is not functioning.
- the shower toilet cannot be controlled with the wall-mounted control panel.
In the event of malfunctions, follow the instructions in the shower toilet user manual.
Description of problem | Cause | Fault clearance |
---|
The function cannot be actuated.
The LED display flashes red.
|
Batteries flat
| ▶ Replace the batteries.
→ See “Replacing the batteries”,
page 8.
The function cannot be actuated.
|
Malfunction has occurred
| ▶ Check the batteries in the wall-mounted control panel.
▶ Check the mains connection to the shower toilet.
▶ Re-assign the wall-mounted control panel.
→ See “Assigning to the wall-
mounted control panel”, page 6.
Sensor window dirty
or wet
| ▶ Clean or dry the wall-mounted control
panel.
The function cannot be actuated.
The LED display flashes red twice, followed by a short
break.
|
Pairing unsuccessful
| ▶ Re-assign the wall-mounted control panel.
→ See “Assigning to the wall-mounted control panel”, page 6.
How to clean the device
Caring for and cleaning smooth surfaces
Aggressive and scouring cleaning agents can damage the surface. Only use
mild, liquid cleaning agents that are kind to the skin. The Geberit AquaClean
cleaning set (art. no. 242.547.00.1) includes a ready-made cleaning agent that
is optimal for cleaning all Geberit AquaClean surfaces.
Prerequisite
- Switch off the shower toilet to prevent the wall-mounted control panel from carrying out any functions during cleaning.
- Clean the surfaces with a soft cloth and a mild liquid cleaning agent.
- Dry the surfaces with a soft cloth.
Disposal
Disposal of waste electrical and electronic equipment
The symbol of the crossed-out wheeled bin means that waste electrical and
electronic equipment (WEEE) must be disposed of separately and not with other
non-recyclable waste. End users are legally obliged to return old equipment to
public waste disposal authorities, distributors, or Geberit for proper
disposal. Many distributors of electrical and electronic equipment are obliged
to take back WEEE free of charge. Contact the responsible sales or service
company to return the WEEE to Geberit.
Used batteries and accumulators that are not enclosed within the old
equipment, as well as lamps that can be removed from the old equipment in a
non-destructive manner, must be separated from the old equipment before being
handed over to a disposal point.
If personal data is stored on the old equipment, end users themselves are
responsible for deleting it before handing it over to a disposal point.
Technical data and conformity
Technical data
Operating temperature | 5–40 °C |
---|---|
Relative humidity | 10–100% |
Frequency range | 2400 MHz–2483.5 MHz |
Maximum output power | 0 dBm |
Wireless technology | Bluetooth® Low Energy1) |
Battery type | CR2032 (3 V) |
Service life of batteries supplied | ~ 2 years |
The Bluetooth® brand and its logos are the property of Bluetooth SIG, Inc. and are under licence by Geberit.
Simplified EU Declaration of Conformity
Geberit International AG hereby declares that the radio equipment type wall-
mounted control panel for Geberit AquaClean complies with Directive
2014/53/EU. The full text of the EU Declaration of Conformity is available at
the following Internet address: https://doc.geberit.com/968860000.pdf.
Simplified UK Declaration of Conformity
Geberit International AG hereby declares that the radio equipment type wall-
mounted control panel for Geberit AquaClean complies with the 2017 Radio
Equipment Regulations. The full text of the UK Declaration of Conformity is
available at the following Internet address:
https://doc.geberit.com/970860000.pdf.
Frequently Asked Questions (FAQ)
Q: What should I do if the LED display does not light up when using the anal
shower?
A: If the LED display does not light up, please ensure that your hand is
positioned correctly around 5 cm in front of the sensor. If the issue
persists, try reassigning the device to the wall-mounted control panel
following the instructions provided.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>