Outsunny A33-027 Inflatable Stand Up Paddle Board Set Owner’s Manual
- June 8, 2024
- Outsunny
Table of Contents
A33-027 Inflatable Stand Up Paddle Board Set
IN230500273V02_GL
Stand-Up-Paddle Board-Set
OWNER’S MANUAL
(All Around SUP Board)
IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY ASSEMBLY & INSTRUCTION MANUAL
ASSEMBLY INSTRUCTIONS
Thank you for choosing this inflatable stand up saddle board (ISUP). To get the best out of your new product you must read and fully understand this user manual.
Get professional instructions before you go stand up paddle boarding. Always be extremely careful when using this product. Only use this product if you are in good physical and mental shape. Due to safety precautions, ISUP’s should only be used on and above water surfaces. While using this product, you’re responsible for your own and others safety. Never go stand up paddle boarding if you are not familiar with the area and surroundings. Never go paddling in strong or offshore winds. Never go paddling on an outgoing tide or strong tidal currents.
All persons should wear a suitable buoyancy aid (life jacket/personal floatation device) when using an ISUP. Be aware that some countries make it is a legal requirement to wear a buoyancy aid that complies with their national regulations.
ISUP Structure Terminology
PACKING LIST
- Stand up paddle board
- Three shafted aluminium adjustable oar
- Hand pump w/ pressure gauge
- Valve wrench
- Repair kit
- Professional carry bag
- Middle fin
- Instruction manual
SET-UP PREPARATION
1.Remove the board from the packaging.
Choose a smooth and clean surface and unroll your board so it lays
top-side up.
2.Valve operation
Follow the instructions below to inflate and deflate the ISUP properly.
The inflation valve is near the nose of the board. To close off the
valve for inflation, ensure the centre valve pin is in the UP position.
For deflation, press the valve pin so it is in the DOWN position.
Be careful of any sand or debris around the valve area when deflating
– small particles could become airborne with the release of the air
pressure.
Always lock the valve cover over the stem when in use. This will prevent
accidental air release and any particles getting into the openings.
3.ISUP Board inflation Steps
a.Unscrew the valve cap and press down on the pin to open the
valve. Let the air flow naturally into the product, then press down on
the pin again to close the valve (in the ‘UP’ position).
b.Make sure the pump hose is connected to the ‘inflate’ outlet.
c.Attach the pump hose with a half twist clockwise onto the valve.
d.Start pumping air into the board by sliding the piston up and down.
Inflate until you reach the required pressure. Minimum 12psi for
proper ISUP operation and a maximum of 15psi for this product.
e.After inflation, tighten the valve cap, so the board stays secure.
4.Fin installation
The two side fins are fixed onto the product. Once the board is
inflated, slide in the middle fin to the base and insert the fixed pin.
5. Inflation tips and precautions
DO NOT use an air compressor – if your board gets damaged from over inflation, it will void your warranty.
After a few days, the pressure could decrease due to temperature change – add a few more pumps of air.
Before using, inflate the board for a full 24 hours to ensure the board is secure. If you see a consistent decrease in air pressure, follow the instructions for leak detection in the repair section of this manual. DO NOT over inflate this board – the maximum pressure should be 15 psi. To ensure the pressure is good, check the chambers are firm by pressing on them.
DO NOT pump to a high pressure and expose the board to direct sun light. If the board is in a warm environment, slightly deflate the board – the heat from the sun will increase the internal pressure. When pad dling, the cold water could cause a slight loss in chamber pressure. It is recommended to carry a pump to use when necessary.
Put the four buckles on the seat into the D-ring of the paddle.
ALU telescopic ISUP paddle
Your board paddle comes in three pieces. To build the paddle, hold the button in while sliding the pieces together until they click into place. The last section (top) of the paddle is adjustable. To find the ideal height for your paddle, start by building the paddle so it is 6 inches taller than your own height. From this point, adjust the top sec tion up or down until the length is comfortable for you. a longer paddle is better suited for a smooth, easier paddling motion. A shorter paddle is good for performance or competition riding.
After closing the button, if the adjustable section is a little loose, tighten the screw properly using a screwdriver.
Features:
Adjustable length from 165-205 cm
Light and FLOATING: 960g
Shaft of 29 and 27mm in alloy 6005-T6
Compact: Removable in 3 parts of 79cm
LEAK DETECTION AND REPAIR
Air Leak Detection
If the board is losing air pressure which isn’t caused by cold tempera tures, check the board for leaks starting with the valves. A leaking valve is rare – if this does happen, we will send a replacement. To find a leak, it is recommended mixing soap and water in a spray bottle, then spray around the valve. If bubbles appear, check the valve seating and base to ensure it is screwed tight. If the problems persist, it is best to get a new valve.
If the board is losing air and there is no issue with the valves, it could be a small puncture. Spray around the board until air bubbles appear – mark the position of the leak. If there are no air bubbles, inflate the board to its maximum capacity and listen for any leaks. If you can narrow the area of the puncture, spray the board so you can identify where the leak is.
Repair Kit
Punctures less than 1/8” can be repaired without a patch. Deflate your board, then clean and dry the area that needs repairing. Apply a small drop of glue to cover the puncture – let it dry for 12 hours.
If the punctures are bigger, use the patches in the repair kit and follow these steps:
- Ensure the board is fully deflated, dry and laying flat.
- Cut a patch that is two inches bigger than the tear on all sides.
- Use alcohol to clean the repair area that needs repairing.
- Apply three coats of adhesive to both the patch and board. Wait 5 minutes between each coat.
- Place the patch over the tear – the adhesive will react quickly, so ensure the positioning is accurate. Use the roller to keep the patch flat and even.
- Wait 24 hours before inflating the board.
INSTRUCTION FOR CARE AND STORAGE
ISUPs are easy to transport and store – just follow these steps:
- Before storing, rinse the board and let dry completely to prevent mildew.
- Do not use harsh chemicals when cleaning – it is best to clean with mild soap and fresh water.
- The board can be stored inflated or deflated. If deflating, it is recom mended to use the provided bag when storing.
- If storing the board outdoors, keep it off the ground and use a cover to keep it from direct sunlight.
- Hanging the board is not recommended.
- Do not store above 66℃/150℉or below-23℃/-10℉.
- Store in a clean and dry place.
- When storing your board deflated, it is best to leave it loosely rolled or unrolled.
- If the fins become bent, place them in boiling water to soak for a few minutes or use a hairdryer, before bending them back to position.
FOR YOUR SAFETY
-10-
WARNING
- Check your board and equipment before entering the water.
- Avoid going in the water alone. Make sure that somebody knows where you are going and when you plan to be back.
- Always have some sort of communication should you need help, for example a mobile phone in a dry bag.
- Check the weather conditions, forecast and tides.
- Avoid paddling when winds are blowing away from shore.
- Be cautious of the effect the tide and water flow can have on your paddling speed and build this into your route plan.
- Wear wetsuits or dry suits.
- Always wear a life jacket or some sort of floatation device.
- Always wear your board leash.
- It is recommended to take a first aid course and travel with first aid equipment.
- Do not use this board if you cannot swim.
- Do not go in the water if you are under the influence of alcohol, drugs or medication.
If you have any questions, please contact our customer care center.
Our contact details are below:
Phone 001-877-644-9366
MW customerservice@aosom.com
Imported by Aosom LLC
27150 SW Kinsman Rd Wilsonville, OR 97070 USA
MADE IN CHINA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>