HIKVISION DS-KD7003EY Series Module Door Station User Guide

June 4, 2024
Hikvision

hikvision-logo

HIKVISION DS-KD7003EY Series Module Door Station

HIKVISION-DS-KD7003EY-Series-Module-Door-Station-
PRODUCT

Quick Guide

HIKVISION-DS-KD7003EY-Series-Module-Door-Station-FIG-1

Appearance and Interface

  1. The pictures here are for reference only.
  2. The nametag can be replaced.

HIKVISION-DS-KD7003EY-Series-Module-Door-Station-FIG-2

Adjust Loudspeaker/Mic

HIKVISION-DS-KD7003EY-Series-Module-Door-Station-FIG-3

AP Mode

HIKVISION-DS-KD7003EY-Series-Module-Door-Station-FIG-4

Operation Sound Function Backlight

Long press

for 10 s

| 1 Beep| Enable/Extend

AP Mode

| Flashing
Long press

for 15 s

| 2 Beeps| Disable AP

Mode

| /
Press| /| Call Room No.2| /

Pairing and Synchronization

Reset

If a power adapter is provided in the device package, use the provided adapter only. If no power adapter is provided, ensure the power adapter or other power supply complies with Limited Power Source. Refer to the product label for the power supply output parameters.

About this Document

  • This Document includes instructions for using and managing the Product. Pictures, charts, images, and all other information hereinafter are for description and explanation only.
  • The information contained in the Document is subject to change, without notice, due to firmware updates or other reasons. Please find the latest version of the Document on the Hikvision website (https://www.hikvision.com). Unless otherwise agreed, Hangzhou Hikvision Digital Technology Co., Ltd. or its affiliates (hereinafter referred to as “Hikvision”) make no warranties, express or implied.
  • Please use the Document with the guidance and assistance of professionals trained in supporting the Product.

About this Product
This product can only enjoy the after-sales service support in the country or region where the purchase is made.

Acknowledgment of Intellectual Property Rights

  • Hikvision owns the copyrights and/or patents related to the technology embodied in the Products described in this document, which may include licenses obtained from third parties.
  • Any part of the Document, including text, pictures, graphics, etc., belongs to Hikvision. No part of this Document may be excerpted, copied, translated, or modified in whole or in part by any means without written permission.
  • HIKVISION and other Hikvision’s trademarks and logos are the properties of Hikvision in various jurisdictions.
  • Other trademarks and logos mentioned are the properties of their respective owners.

LEGAL DISCLAIMER

  • TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS DOCUMENT AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE, AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
  • YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACKS, HACKER ATTACKS, VIRUS INFECTIONS, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
  • YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, DATA PROTECTION, AND OTHER PRIVACY RIGHTS. YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
  • IN THE EVENT OF ANY CONFLICTS BETWEEN THIS DOCUMENT AND THE APPLICABLE LAW, THE LATTER PREVAILS.

Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.

Set Physical Address

Door Station
Use the rotary DIP switch to set the building No., door station No., sub door station, and outer door station No. and door open duration. The Tens column refers to the number in Tens, and the Units column refers to the number in Units. On each rotary DIP switch, 0 to 9 refers to No. 0 to 9. In total, you can use 1 to 99 to number the building. If the door station is the main door station, the Door Station No. should be set as 0; If it is sub door station, set Door Station No. as 1~16; If it is an outer door station, set Door Station No. as 90~99. Use the screwdriver to adjust the number. The arrow indicates the number.HIKVISION-DS-KD7003EY-Series-Module-Door-Station-
FIG-7

Indoor Station

No. Settings
Use the rotary DIP switch to set the indoor extension No., the building No., and the room No. The Tens column refers to the number in Tens, and the Units column refers to the number in Units. On each rotary DIP switch, 0 to 9 refers to No. 0 to 9. In total, you can use 1 to 3 to number the indoor extension No., and 1 to 99 to number the building or the room. Use the screwdriver to adjust the number. The arrow indicates the number.

Device Mode Settings
Use the rotary DIP switch to set the indoor station’s device mode according to actual scenarios.

  • Villa Mode: Under the villa mode, the device needs to be powered by a 12 VDC power supply. More than one device can be lightened up; when the extension is called, it can be lightened up and intercoming via videos.
  • Building Mode : In one power supply system, up to 4 indoor stations can be wired and up to 1 indoor station can be normally used at the same time. When other devices are lightened up, the IN USE indicator will also be lightened up. The separate power supply is not supported. When the extension is called, the screen cannot be lightened up.

For example

HIKVISION-DS-KD7003EY-Series-Module-Door-Station-FIG-8

  • DIP 1 and DIP 2 are for mode settings, and DIP 3 and DIP 4 are reserved.
  • If DIP 2 is set as 1, the function of Professional Studio can be set.
  • The device is on debugging mode when the extension No. is 9. You can operate the indoor station on debugging mode without connecting to the door station.

System Wiring

HIKVISION-DS-KD7003EY-Series-Module-Door-Station-FIG-9

Wiring

HIKVISION-DS-KD7003EY-Series-Module-Door-Station-
FIG-10

Cable Type Description

Cable Type| DS-KAD7061 to DS-KAD7061|

DS-KAD7061 to

Main Indoor Station

|

Indoor Station to Indoor Station

|

DS-KAD7061 to DS-KAD7060

| DS-KAD7060 to

Power Module/DS- KAD7060-S

| DS-DS-KAD7060 to Door Station| Door Station to Lock (Power Supply)
---|---|---|---|---|---|---|---
UTP 5 0.2 mm 2 (Cat.5) AWG24|

60 m

|

60 m

|

60 m

|

60 m

|

100 m

|

60 m

|

NA

0.28 mm 2 (TP) AWG23|

60 m

|

40 m

|

40 m

|

40 m

|

80 m

|

40 m

|

30 m

0.5 mm 2 (parallel) AWG20|

60 m

|

60 m

|

60 m

|

60 m

|

100 m

|

60 m

|

50 m

1 mm 2 (parallel) AWG17|

60 m

|

60 m

|

60 m

|

60 m

|

100 m

|

60 m

|

50 m

1 mm 2 (TP) AWG17|

60 m

|

40 m

|

40 m

|

40 m

|

80 m

|

40 m

|

100m

1 mm 2 (parallel) AWG15|

60 m

|

40 m

|

60 m

|

60 m

|

100 m

|

60 m

|

100 m

Installation

Note: Video intercom module door station supports one-module installation, two-module installation, and three-module installation. Here is a three-module installation as an example.

Before You Start
Tools that you need to prepare for installation: Drill(6), cross screwdriver (PH1*150mm), and gradient. Make sure all related equipment is powered off during the installation. Make sure you have configured the sub-module address before installation. Valid sub-module address ranges from 1 to 20. The No. should be unique for sub-modules that are connected to the same door station. The sub-module address and corresponding DIP switch status are shown in the figure shown.

Sub Module

No.

| DIP Switch 1| DIP Switch 2| DIP Switch 3| DIP Switch 4| DIP Switch 5| DIP Switch 6| DIP Switch 7| DIP Switch 8
---|---|---|---|---|---|---|---|---
Module 1| ON| OFF| OFF| OFF| OFF| OFF| OFF| OFF
Module 2| OFF| ON| OFF| OFF| OFF| OFF| OFF| OFF
Module 3| ON| ON| OFF| OFF| OFF| OFF| OFF| OFF
Module 4| OFF| OFF| ON| OFF| OFF| OFF| OFF| OFF
Module 5| ON| OFF| ON| OFF| OFF| OFF| OFF| OFF
Module 6| OFF| ON| ON| OFF| OFF| OFF| OFF| OFF
Module 7| ON| ON| ON| OFF| OFF| OFF| OFF| OFF
Module 8| OFF| OFF| OFF| ON| OFF| OFF| OFF| OFF

Flush Mounting

HIKVISION-DS-KD7003EY-Series-Module-Door-Station-
FIG-11

Surface Mounting

HIKVISION-DS-KD7003EY-Series-Module-Door-Station-
FIG-12

Configuration

Configuration and Management via Mobile Web Enable AP Mode→Login

  1. Long press the button on the left side of the device for 10 s to enable the AP mode.
  2. Connect your mobile devices to the device hotspot. Enter the device user name and AP password. Tap Login.
    • You can check the AP mode password (Access Code) via the label on the surface of the device.

Call the Indoor Station from the Door Station/Outer Door Station/Sub Door Station

  1. Set physical address for indoor station and door station/outer door station/sub door station via the rotary DIP switch.
  2. Connect the indoor station and door station/outer door station/sub door station.
  3. Call the indoor station from the door station/outer door station/sub door station.

For more details about the configuration, please refer to the User Manual.

Installation Position

Recommended Installation Height (The distance between the camera and the ground): 1.4 m to 1.6 m The FOV of the camera is : Horizontal: 133°, Vertical: 82°. The highest visual height and lowest visual height of the camera are shown in the picture.HIKVISION-DS-KD7003EY-Series-Module-Door-Station-
FIG-14

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)