Silk n H3104 Infinity Fast User Manual
- June 1, 2024
- Silk n
Table of Contents
- H3104 Infinity Fast
- Warnings
- Contraindications
- Safety with Silk’n
- Get to know your device
- Device controls and settings
- What to expect with the device
- Possible side effects
- Treatment plan
- Get started!
- Cleaning and maintenance
- Troubleshooting
- Customer service
- Warranty
- Disposal
- Specifications
- Signs and symbols
- Labeling
- Technical results
- Legal notice
- Documents / Resources
Infinity Fast
H3104 USER MANUAL
H3104 Infinity Fast
Warnings
Please read this user manual in full before use.
We recommend you refamiliarise yourself with the instructions before each
treatment session.
Do not use the device for any purpose other than as described in this user
manual.
Electricity and safety warnings
- Do not use the device while bathing or taking a shower.
- Do not attempt to reach for the device if it has fallen into water.
- Keep the adapter accessible at all times, so it can be removed from the electricity supply easily in case of emergency. Never pull the adapter by the cable.
- Always switch the device off and disconnect it from the electricity supply when you are not using the device, when you intend to clean it, or in the event of a fault.
- Possible hazardous optical radiation is emitted from this device. Do not look at the operating lamp. Eye injury may result.
- Do not use the device where there is monitoring equipment (e.g., cardiac monitors, ECG alarms), which may not operate properly when the device is in use.
- Do not use if the parts or accessories are not supplied by the manufacturer as defined in this manual, or if the device is damaged in any way, does not appear to be working properly, or if you see or smell smoke.
- Do not attempt to modify, open or repair the device. You may expose yourself to an electric shock. It will also void the warranty.
- The manufacturer accepts no liability for damage or injuries caused by improper or incorrect use.
- Children must not play with the device or any of its parts or the packaging. They may injure themselves with the packaging material, or swallow small parts and choke.
- Do not use the device in close proximity (e.g. 1 m) to shortwave or microwave therapy Medical equipment which may produce instability in device Galvanic current output.
- Do not use the device near the thorax, the Galvanic current may increase the risk of cardiac fibrillation.
- Do not use the device on the eyes, on the mouth, on the front of the neck (especially the carotid sinus), or from electrodes placed on the chest and the upper back or crossing over the heart.
- Never use the device if the yellow window is cracked or broken.
- During use, make sure that the yellow window does not touch the skin.
Contraindications
- The device must not be used by the following people: children, adults with limited physical, sensory or psychological capacities, or those lacking experience or knowledge in how to use the device.
- The device is not designed for everyone. Hair removal by lasers or intense pulsed light sources can cause increased hair growth in some individuals. Based upon currently available data, the highest risk groups for this response are females of Mediterranean, Middle Eastern and South Asian heritage treated on the face and neck. If you are not sure if is for you, please contact your dermatologist.
- The device is intended for self treatment only. Do not operate the device on an individual other than yourself.
Do not use if you:
- have naturally dark skin (refer to the skin color chart at the front of this user manual). Treating dark skin can result in adverse effects such as burns, blisters, and skin color changes (hyper- or hypo-pigmentation).
- have naturally white, grey, blond and red body hair. If your body hair is of these colors, the device will not work on you.
- are pregnant or nursing.
- were exposed to strong sunlight or an artificial tanning machine during the past 4 weeks.
- have a history of keloidal scar formation, a known sensitivity to light (photosensitivity) or are taking medication that makes the skin more sensitive to light, including non-steroidal anti-inflammatory agents, (e.g., aspirins, ibuprofens, acetaminophen), tetracyclines, phenothiazines, thiazide, diuretics, sulfonyluraes, sulfonamides, DTIC, fluorouracil, vinblastine, griseofulvin, Alpha-Hydroxi Acids (AHAs), Beta-Hydroxi Acids (BHAs), Retin-A®, Accutane® and/or topical retinoids.
- have abnormal skin conditions caused by diabetes, for example, or other systemic or metabolic diseases.
- are currently or have recently been treated with AlphaHydroxi Acids (AHAs), Beta-Hydroxi Acids (BHAs), Retin-A®, topical retinoids or azelaic acid.
- have been treated with Accutane® (isotretinoin) within the past 6 months.
- have received drugs from your physician for a skin condition within the past 6 months.
- have been on a steroid regimen within the past 3 months.
- suffer or have suffered from epilepsy.
- have an active implant, such as a pacemaker, incontinence device, insulin pump, etc.
- have a disease related to photosensitivity, such as porphyria, polymorphic light eruption, solar urticaria, lupus, etc.
- have a history of skin cancer or areas of potential skin malignancies.
- have received radiation therapy or chemotherapy treatments within the past 3 months.
- are allergic to metal, or are sensitive to contact with chrome.
- cannot sense heat properly because of an illness, or other health related issue.
- have any other condition which in your physician’s opinion would make it unsafe for you to use the device.
Do not use on these parts of the body:
-
Areas where you have metal braces or a metal implant.
Consult your physician if you are in any doubt. -
Around or near the eyes. Use below the cheekbones.
-
On tattoos or permanent makeup, dark brown or black spots, (such as large freckles, moles, or warts), nipples, genitals, or lips.
-
Areas with injected fillers or toxins.
-
Areas that are prone to rosacea.
-
Areas that are painful.
-
A part of the body that has a history of herpes outbreaks, unless you have consulted your physician and received preventative treatment before using the device.
-
Skin that has active eczema, psoriasis, lesions, open wounds or infections (cold sores), abnormal skin conditions caused by systemic or metabolic diseases (diabetes for example).
-
Areas where you may want hair to grow later. The results are long-lasting.
Safety with Silk’n
With Silk’n safety comes first. Enhanced Home Pulsed Light™ (eHPL) technology
provides superior safety with lower energy levels.
eHPL™ is able to achieve long-term hair removal results at a fraction of the
energy level used in other light-based hair removal equipment. The technology
combines 2 energy sources: galvanic energy and optical energy. The galvanic
energy enables better penetration of the optical energy to the hair shaft by
temporarily widening the skin pores. The hair shaft absorbs the light,
deactivates the hair follicle and hair growth is disabled.
The low energy used reduces its potential to cause harm or complications and
contributes to your overall safety.
Silk’n protects your skin
Light-based hair removal is not suitable for tanned skin. The device comes
with a built-in skin color sensor that is designed to measure the complexion
of the applied surface and enables energy levels according to skin complexion.
Furthermore, the treatment surface, through which pulses of light are
delivered, is recessed inside the device. This enables the device to protect
your skin by avoiding direct contact between the treatment surface and the
skin.
Silk’n protects your eyes
The device has a built-in safety feature for eye protection. It has been
designed so that a light pulse cannot be emitted when the treatment surface is
facing open air. The safety feature enables treatment only when the treatment
surface is in contact with the skin.
Get to know your device
4.1 Package contents
- Hair removal device
- Power adapter
- Storage case
- Cleaning cloth
- User manual
4.2 Device description
The device is for home-use and uses eHPL™ technology for the removal of
unwanted hair. The device has a treatment surface and a pulse button. It also
has a pair of electrodes, base and touch, for creating and utilizing a
galvanic treatment circulation.
Refer to the diagram at the front of the manual to see the location of each
feature.
- Pulse button (#1)
- Treatment surface (#2)
- Skin color sensor (#3)
- Energy level indicator lights (#4)
- Control button (#5)
- Ready/skin tone warning indicator light (#6)
- Base electrode (#7)
- Touch electrode (#8)
4.3 Intended use
The device is an over the counter device intended for the removal of unwanted
hair. The device is also intended for permanent reduction in hair regrowth,
defined as the long-term, stable reduction in the number of hairs regrowing
when measured at 6, 9, and 12 months after the completion of a treatment
regime.
The device is a skin-toning device, intended for skin stimulation and
indicated for over the counter cosmetic use and is suitable for people over
the age of 17.
Device controls and settings
5.1 Device controls
Refer to the diagram at the front of the manual to see the location of each
control.
Control | Action | Function / Mode |
---|---|---|
Control button (#5) | Short press | Each press increases the energy level. The |
default at start up is level 1. Cycle through the levels to get back to 1.
Pulse button (#1)| Short press| Triggers a light pulse.
Touch electrode (#8)| When in contact with the skin| Triggers a light pulse
when pressed together with the pulse button (#1).
Energy level indicator lights (green) (#4)| Constant| The number of lights
indicates the energy level.
Ready/skin tone warning indicator light (green) (#6)| Constant| Device is
ready for use.
Blinks rapidly| Skin tone is too dark for safe use. No light pulses are
emitted.
5.2 Skin color sensor
Light-based hair removal on darker skin tones may result in adverse effects
such as burns, blisters, and skin color changes (hyper- or hypo-pigmentation).
The device has a skin color sensor (#3) that detects the color of your skin
automatically.
The skin color sensor checks your skin color at the start of, and occasionally
during, each treatment.
If you see no light pulse and the ready/skin tone warning indicator light (#6)
blinks rapidly, this is an indication that your skin tone, measured by the
skin color sensor (#3), is too dark for safe application. Try using the device
on a different part of your body.
5.3 Energy levels
The energy level determines the intensity of the light pulse projected on your
skin during use, from the lowest level to the highest level. The indicator
lights on the device illustrate the energy level at which the machine is set.
Select the energy setting carefully. When the energy intensity is increased,
hair removal improves, but the risk of side effects and complications
increases.
- The device has 5 levels of energy from 1 (the lowest) to 5 (the highest), represented by 5 energy level indicator lights (#4).
- When the device is turned on, the energy level is set to level 1 automatically. Only one energy level indicator light (#4) will be on.
- To change the energy level, press the control button (#5) repeatedly to increase the energy level from 1 to 5. Once at level 5, press the control button (#5) again to reduce the energy level from 5 back to 1.
Do not increase energy levels during a treatment session even if you feel no
discomfort. Discomfort may appear some time after the treatment session.
Always begin your first use at the lowest energy setting!
Follow the skin color chart when selecting energy levels to avoid the risk of
burns, blisters or changes in skin color (see the chart at the front of the
manual).
5.4 Pulsing and gliding Pulsing is the best technique for
treating specific spots or small areas.
- Press the treatment surface (#2) against your skin. Work in rows (either across or down as shown in the image). Start at one end of each row and progress to the other end.
- The treatment surface (#2) creates temporary pressure marks on the treated area so you can see areas you have treated.
- After each pulse, move the treatment surface (#2) to the next spot. Keep doing this pulsing action for the area you are treating.
- Avoid gaps or overlaps as you use the device.
Gliding is the best technique for treating larger parts of the body.
Press the treatment surface (#2) firmly against your skin and slowly glide
over your skin (either across or down as shown in the image). Make sure that
the treatment surface (#2) is always touching your skin.
- At lower energy levels, the device takes only 1-1.5 seconds to recharge between pulses. This generates a nonstop sequence of flashes.
- Glide at a speed so that you avoid gaps or overlaps.
Do not treat the same area of skin more than once per hair removal session.
Stop use immediately if you have any pain, or if the skin becomes too hot.
5.5 Exposure to the sun
-
Sun exposure includes constant unprotected exposure to direct sunlight for over 15 minutes, or constant unprotected exposure to diffuse sunlight for over 1 hour.
-
Do not use on tanned skin after recent sun exposure, including tanning machines. Using the device on skin that has been recently exposed to sunlight can result in adverse effects such as burns, blisters, and skin color changes (hyper- or hypo- pigmentation).
Avoid further exposure to the sun for 4 weeks before and 2 weeks after your treatment. This is because higher quantities of melanin expose the skin to greater risk when using any method of light-based hair removal. This applies to all skin types, even those that don’t seem to tan quickly. -
We don’t advise it, but if you have to go out in the sun after a treatment, be sure to apply sunscreen SPF30 or higher to the treated area. Do this for 2 weeks after a treatment.
What to expect with the device
During a treatment session it is normal to experience and feel:
- A fan noise: The cooling fan makes a noise similar to that of a hair dryer.
- A pop sound with each pulse: When a pulse of eHPL™ light is activated, it is normal to hear a subtle pop sound simultaneously with the flash of light.
- A sensation of warmth and tingling: During each galvanic pulse sequence it is normal to feel a mild sensation of warmth and tingling from the galvanic and light energies.
- Some mild red or pink color: During and just after your treatment session it is not uncommon to see some very mild, pink-like color of the skin. This is usually most noticeable around the hairs themselves.
Stop use immediately if you see full redness of the skin, blistering or burns.
Possible side effects
When used according to the instructions, side effects and complications
associated with the use of the device are uncommon. However, every cosmetic
procedure, including those designed for home use, involves some degree of
risk.
Therefore, it is important that you understand and accept the risks and
complications that can occur with pulsed light hair removal systems designed
for home use.
There is a minor risk that stacking or overlapping of multiple pulses on the
same skin spot may have some adverse effects.
Minor skin discomfort
Home pulsed light hair removal is generally well-tolerated.
However, some users feel mild discomfort during use. This is best described as
a mild stinging sensation on the treated skin areas.
The stinging sensation may last during or after treatment.
This means that you should use the device at a lower energy level, and if that
doesn’t help, you should stop using the device.
Skin redness
Your skin may become red immediately after using the device or within 24
hours. Redness generally clears up within 24 hours.
See your doctor if redness does not go away within 2 to 3 days.
Make sure you use the energy level that is comfortable for you and suitable
for your skin color.
Increased sensitivity of the skin
The skin of the treated area is more sensitive so you may encounter dryness or
flaking of the skin.
Blisters or burns
Cool the affected area and apply anti-burn cream. Wait until the area has
healed completely before another treatment, and use a lower energy level. If
the skin does not return to normal within 3 days, consult your physician.
Skin wounds and burns
Very rarely, burns or wounds to the skin can occur following the application.
The burn or wound can require a few weeks to heal and, extremely rarely, may
leave a noticeable scar.
Scarring
Although very rare, scarring may occur. Usually when scarring occurs, it is in
the form of a flat and white lesion on the skin (hypotrophic). However, it can
be large and red (hypertrophic) or large and extend beyond the margins of the
injury itself (keloid).
Subsequent aesthetic treatments may be required to improve the appearance of
the scar.
Pigment changes
The device targets the hair shaft, in particular the pigmented cells in the
hair follicle and the hair follicle itself. Nevertheless there is a risk of
temporary hyper-pigmentation (increased pigment or brown discoloration) or
hypo-pigmentation (whitening) to the surrounding skin. Risk of changes in skin
pigmentation is higher for people with darker skin tones or heavily tanned
skin. Usually discoloration or changes to skin pigment are temporary, and
permanent hyper-pigmentation or hypo-pigmentation are rare. Excessive
redness and swelling
In rare cases, treated skin may become very red and swollen. This is more
common in sensitive areas of the body. The redness and swelling should subside
within 2 to 7 days and should be treated with frequent applications of ice.
Gentle cleansing is OK, but avoid exposure to the sun.
Infection or bruising
Infection of the skin is exceedingly rare but is still a possible risk
following a skin burn or wound caused by the device.
Very rarely, the device may cause blue-purple bruising that can last 5 to 10
days. As the bruising fades, there may be a rust-brown discoloration of the
skin (hyperpigmentation).
Stop use immediately if any of these effects are more severe.
See your physician if the effects do not go away within 2 to 3 days.
Treatment plan
A typical full hair growth cycle may take 18-24 months. During this time
multiple treatment sessions may be required in order to achieve long-lasting
hair removal.
The efficiency of hair removal varies from person to person according to body
area, hair color and how the device is used.
Typical treatment plan during a full hair growth cycle:
- Treatments 1-4: Plan two weeks apart.
- Treatments 5-7: Plan four weeks apart.
- Treatments 8 +: Treat as needed, until desired results are achieved.
Ideal body areas include underarms, bikini area, arms, legs, back shoulders and chest (excluding nipples). For the face, use below the cheekbones but not around or near the eyes or lips.
Get started!
9.1 Connect the device
- Remove the device and other components from the box.
- Place the adapter cord into the device and connect to the electricity supply. All the energy level indicator lights (#4) will go on and off repeatedly in a circular motion.
9.2 Do a spot test
IIt’s important to do a spot test on each part of the body you wish to treat.
A spot test checks that the skin color is suitable for treatment, and that you
know which energy level is comfortable for the area you are treating. Both
skin color and energy level may vary depending on the target treatment area.
- To do a spot test, follow steps 1-5 and 7-9 in the next section.
- If you experience little or no discomfort during and after use at the lowest energy setting, increase the energy level by one indicator light the next time you use the device, and so on for each subsequent hair removal session.
- Repeat the spot test for each area you wish to treat.
9.3 Treatment steps
-
Remove all jewelry before use.
-
Before treatment, the skin should be shaved, clean, dry and free of any powders, antiperspirants or deodorants. Do not wax, pluck or tweeze the hair out.
Never use flammable liquids such as alcohol (including perfumes, sanitizers, or other applications containing alcohol), or acetone to clean the skin before use. -
Be sure to cover up tattoos, moles, warts, large freckles, black spots or other marks on the skin that should not be treated. Use a material that does not absorb the light such as a white cloth or white medical tape.
-
Press the control button (#5). The device will turn on, the level 1 energy level indicator light (#4) will be on, and a fan sound will start.
-
Approximately 1 second after pressing the control button (#5), the ready/skin tone warning indicator light (green) (#6) will turn on. The device is now ready for you to trigger the first pulse at the lowest energy level. Always start at energy level 1 for your first treatment.
-
Select the energy level you are most comfortable with.
-
Place the treatment surface (#2) on the skin and press the pulse button (#1) to deliver one pulse. Make sure your hand touches the base electrode (#7) together with the pulse button (#1).
If you do not make hand contact with the base electrode (#7), no galvanic treatment circulation will be emitted. -
Press the pulse button (#1).
• The device first determines the skin color. If the skin color is light enough for safe application, the device will activate the galvanic circulation. You might feel a slight tingling sensation. This is completely normal.
The galvanic treatment works to enlarge your pores for a better application of the treatment.
• Directly afterwards, the device will flash a pulse of light onto your skin, and the ready/skin tone warning indicator light (#6) will turn off. You will see a bright flash of light and simultaneously hear a popping sound, which is a normal noise for the device. You will feel a mild sensation of warmth and tingling. The device will immediately recharge for the next pulse.
• After a few seconds the ready/skin tone warning indicator light (#6) will turn on again and start blinking slowly when pressed against the skin. -
Remove the treatment surface (#2) from the treated area of skin.
-
Decide if you wish to treat the area by Gliding or Pulsing (see section 5.4 Pulsing and gliding).
• If you are Pulsing, place the treatment surface (#2) on an adjacent part of your skin, and trigger a pulse.
• If you are Gliding, hold the pulse button (#1) down continuously and slide the device smoothly along the treated area. -
Keep Pulsing or Gliding until you have covered the target area.
Try to avoid gaps or overlaps. Overlaps increase the likelihood of adverse affects.
The device will only emit repeated pulses when it is in firm contact with your skin, and you keep moving it across your skin. -
When you have completed your treatment, long press the control button (#5), to switch off the device. Remember the last energy setting you used because the device always starts up at energy level 1.
-
Disconnect the adapter (#9) from the electricity supply, then clean the device and store safely (see section 10. Cleaning and maintenance).
-
After your treatment session we recommend you apply a body lotion to the treated area to help your skin recover from the treatment faster.
Cleaning and maintenance
- Disconnect the device from the electricity supply.
- To clean the device including the treatment surface (#2), use a clean, dry cloth and 70% alcohol. Never use acetone or other abrasive fluids, because they will damage your device. Then use a wipe to dry the device.
- After cleaning, we recommend you store the device in its original box and keep it away from water.
Troubleshooting
Only authorized personnel are permitted to perform repairs.
Do not attempt to modify, open or repair the device. You may expose yourself
to dangerous electrical components and may cause serious harm to yourself. It
will also void the warranty.
Contact Customer Service if you have a broken or damaged device in need of
repair.
-
My device does not start.
Check that:
• the adapter is properly connected to the device and that it is plugged into the electricity supply. -
There is no galvanic pulse when I press the pulse button (#1).
Check that:
• your hand is touching the base electrode (#7) when you press the pulse button (#1).
The treatment circulation requires closing the circuit by pressing the trigger and the electrode at the same time, in order to effectively treat your skin. -
There is no light pulse when I press the pulse button (#1).
Check that:
• the green ready/skin tone warning indicator light (#6) is blinking slowly to ensure you have good contact with the skin.
• the treatment surface (#2) is evenly and firmly pressed to the skin. For your safety, the pulse button (#1) will activate a pulse only if the treatment surface (#2) is firmly pressed against the skin.
• If the ready/skin tone warning indicator light (#6) blinks rapidly, this is an indication that your skin tone, measured by the skin color sensor (#3), is too dark for safe use, or that the skin color sensor (#3) was not properly covered by your skin. Try using the device on a different body part or contact Silk’n customer support. -
One or more lights are on constantly.
The device has malfunctioned.
Unplug the device and do a restart. If the problem persists, contact Customer Service. -
The device has stopped working and is in standby mode.
Press the control button (#5) again to start the device.
Customer service
For more information about Silk’n products, visit your regional Silk’n
website: www.silkn.com or www.silkn.ca. If the device is damaged, defective,
in need of repair or if you need our assistance, please contact your nearest
Silk’n service center. This manual is also available as a PDF download from
these websites.
Service number: 1-800-250-5053
(toll-free)
Email:customercarena@silkn.com
Warranty
This product is covered by a 1-year warranty. The extent of the warranty on
this product is limited to technical defects caused by faulty production
processes. In the event you want to claim warranty please be sure to contact
our customer service for instructions. They may be able to solve your problem
without needing to return the product to the store or our service centre.
Our customer service is always pleased to help you!
The manufacturer accepts no liability for damage or injuries caused by
improper or incorrect use.
Disposal
Dispose of the packaging separated into single type materials. Dispose of
cardboard and carton as waste paper and film via the recyclable material
collection service.
Do not dispose with household waste! The WEEE directive requires that you
dispose of this electrical device (including all accessories and parts) at a
designated recycling collection point for electrical devices. This ensures
that the device is recycled professionally, and prevents the release of
harmful substances into the environment. Make sure that the device is in an
uncharged state before disposal.
Products labelled with Cd = cadmium, Hg = mercury, Pb = lead.
Specifications
Model | H3104 |
---|---|
Galvanic | 70-420 Microampere (µA) |
Spot size | 0.9cm x 3cm [2.7cm²] |
Technology | Enhanced Home Pulsed Light™ |
Max energy level | Max 3-5J/cm² |
Wavelength | 520-1200nm |
Pulse light duration | 500-800µs |
Mode of operation | Continuous |
Operation and safety | Skin color sensor ensures use only on appropriate skin |
types
Repetition rate:| 2Hz maximum
Galvanic current pulse parameters
(R Load: 500 Ω & 1k Ω.)| Max Output Voltage| Level| Duration [ms]| Frequency
[Hz]| Amplitude [µA Max]
---|---|---|---
1| 200| 2| 400
2| 200| 1.5| 400
3| 200| 1.1| 400
4| 200| 0.85| 400
5| 200| 0.75| 400
Package size| 220x220x90mm
System weight| 225gr
Transport & storage between uses and storage condition| Temperature: – 40° to
+70°C
Relative humidity : 10% to 90%rH
Atmospheric pressure: 500 to 1060hPa
Operating conditions| Temperature: 10° to 35°C
Relative humidity: 30% to 75%rH
Atmospheric pressure: 700 to 1060hPa
Time from minimum storage temperature between uses to minimum operating
temperature with ambient temperature
of 20°C| 30 minutes
Time from maximum storage temperature between uses to
maximum operating temperature with ambient temperature
of 20°C| 30 minutes
Protection against electric shock| Class II medical equipment type
BF applied part
Adapter| KSA-60B-200300D5
Input: 100-240V; 50-60Hz; 1.8A
Output: 20Vdc: 3A
The device was tested and complies with| IEC 60601-1 (Safety)
IEC 60601-1-2 (EMC)
IEC 60601-1-11 (Environment)
IEC 60601-2-10 (Stimulators)
IEC 60601-2-57 (Safety of non-laser source)
Service life of the equipment| 5 years
Signs and symbols
| Degree of protection against electric shock. BF applied part.
---|---
| The device is protected against objects such as fingers, to protect against
electrical shock, and protect from water spray less than 15 degrees from
vertical.
| Keep dry.
| Do not dispose with household waste! The WEEE directive requires that you
dispose of this electrical device (including all accessories and parts) at a
designated recycling collection point for electrical devices.
| Follow the instructions for use.
| Manufacturer.
| Date of manufacture.
| Medical device.
Labeling
This device is not suitable for use in the presence of flammable anaesthetic mixture with air or with Oxygen or Nitrous Oxide.
- The image is for illustration purposes only.
Technical results
The use of accessories other than those specified or sold by Silkn Beauty Ltd.
as replacement parts may have the consequence of increasing the emissions or
decreasing the immunity of the device. The device is intended for use in the
electromagnetic environment specified in the Summary of Test Results.
EMC requirements
IEC 60601-1-2 Edition 4.0 (2014);
IEC 60601-1-2 Edition 4.1 (2020).
Environment of intended uses:
Professional Healthcare and Home Healthcare Facility Environments
Summary of Test Results
Test | Standard | Class/ Severity Level | Test Result |
---|
Emission (IEC 60601-1-2 sections 7.1 & 7.2)
Conducted emission
Freq. range:150 kHz – 30 MHz| CISPR 11| Group 1 Class B:
AC mains 230 VAC/ 120 VAC/ 100VAC
| Complies
Radiated emission
Freq. range: 30 – 1000 MHz| CISPR 11| Group 1 Class B AC mains 230 VAC|
Complies
Harmonic current emission test| IEC 61000-3-2| 230VAC mains| Complies
Voltage changes, Voltage fluctuations and Flicker test| IEC 61000-3-3| 230VAC
mains| Complies
Immunity (IEC 60601-1-2 sections 8.9 & 8.10; 8.11)
Immunity from Electrostatic discharge (ESD)| IEC 61000-4-2| 8 kV contact & 15
kV air discharges| Complies
Immunity from radiated electromagnetic fields| IEC 61000-4-3| 10.0 V/m 80 MHz
¸ 2.7 GHz, 80% AM, 1 kHz| Complies
Immunity from Proximity field from wireless communications equipment| IEC
61000-4-3| List of frequencies,
from 9 V/m up to 28 V/m,
PM (18 Hz or 217 Hz), FM 1 kHz| Complies
Immunity from Electrical Fast transient (EFT)| IEC 61000-4-4| ± 2.0 kV on AC
mains Tr/Th – 5/50 ns, 100 kHz| Complies
Immunity from Surge| IEC 61000-4-5| ±2.0 CM / ±1.0 kV DM on AC mains Tr/Th –
1.2/50 (8/20) ms| Complies
Immunity from conducted disturbances induced by radio-frequency fields| IEC
61000-4-6| 3.0 / 6.0 VRMS on AC mains 0.15÷ 80 MHz, 80% AM, 1 kHz| Complies
Immunity from power frequency magnetic field| IEC 61000-4-8| 30 A/m @ 50 Hz /
60Hz| Complies
Immunity from voltage dips, short interruptions and voltage variations| IEC
61000-4-11| On 100 VAC & 230VAC 50 Hz;
0 % – 0.5 cycle & 1 cycle;
70% – 25/30 cycles; 0% – 250 cycles| Complies
Immunity to proximity magnetic fields in the frequency range 9 kHz to 13,56
MHz| Section 8.11* IEC 61000-4-39| 8 A/m 30kHz CW
65 A/m @134.2kHz PM 2.1kHz 50%
7.5 A/m @13.56MHz PM 50kHz 50%| Complies
**Note: *** This test s not appcable per IEC 60601 -1-2 Edition 4.0 standard
Legal notice
Copyright 2024 © Silkn Beauty Ltd. All rights reserved.
Silkn Beauty Ltd. reserves the right to make changes to its products or
specifications to improve performance, reliability, or manufacturability.
Information furnished by Silkn Beauty Ltd. is believed to be accurate and
reliable at the time of publication.
However, Silkn Beauty Ltd. assumes no responsibility for its use.
No license is granted by its implication or otherwise under any patent or
patent rights of Silkn Beauty Ltd.
No part of this document may be reproduced or transmitted in any form or by
any means, electronic or mechanical, for any purpose, without the express
written permission of Silkn Beauty Ltd. Data is subject to change without
notification. Silkn Beauty Ltd. has patents and pending patent applications,
trademarks, copyrights, or other intellectual property rights covering subject
matter in this document. The furnishing of this document does not give you any
license to these patents, trademarks, copyrights, or other intellectual
property rights except as expressly provided in any written agreement from
Silkn Beauty Ltd. Specifications are subject to change without notice.
Silk’n and the Silk’n logo are registered trademarks of Silkn Beauty Ltd.,
Alon Ha-Tavor 15, Caesarea, 3079516, Israel,
www.silkn.com ,
www.silkn.ca ,
info@silkn.com.
Beauty PB119426B
Issue dat e: 03/2024
Manufacturer:
Silkn Beauty Ltd, Alon Ha-Tavor 15,
Caesarea 3079516, Israel
www.silkn.com
www.silkn.ca
info@silkn.com
Documents / Resources
| Silk
n H3104 Infinity
Fast
[pdf] User Manual
H3104 Infinity Fast, H3104, Infinity Fast, Fast
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>